Fire-Lite MS-5024(E) Fire Alarm Control with Built-in DACT

File Preview
File Preview
Click below to download for free

Text Preview

www firelite com Fire MS 5024 is a 24 volt five zone fire alarm panel with built in communicator The integral com transmits event information alarms troubles faults etc to a UL Listed central station MS 5024 may be used in a variety of cost effective including local fire alarm control panel com disabled fire alarm control panel communica stand alone sprinkler supervisory communicator or communicator to a UL Listed host fire alarm panel N O dry contacts to trigger five channels Se transmission formats allow the MS 5024 to com to virtually all central stations Five programmable Initiating Device Circuits zones zone may be programmed for Two wire smoke detectors N O contact devices pull heat Four wire smoke detectors Waterflow operation Supervisory operation Auto reset supervisory operation Two built in Class B Style Y Notification Appliance Cir NACs Notification Appliance Circuits may be programmed Silenceable Non Silenceable a strobe circuit can keep flashing the panel is silenced Auto Silence program 5 to 30 minutes Silence Inhibit 60 seconds Coding March Time Temporal California 3.0 Amps of Notification Appliance power Two built in fully programmable Form C relays Dual line rotary or Touch Tone DACT interfaces public telephone network leased phone lines are not 24 Volt operation Built in voltmeter measures Zone voltage Primary AC line voltage Battery voltage Notification Appliance Circuit s voltage Resettable 24 volt power Surface Mount Technology SMT Fully programmable via built in keypad no costly exter programmers necessary Complies with NFPA 72 Local Central Station and Re Station DACT only not polarity reversal Fire Systems 12 2004 cid 127 A3 200 cid 22 cid 19 cid 23 cid 29 cid 12 cid 19 cid 28 cid 22 cid 5 cid 26 cid 8 Control Communicators Fire MS 5024 Reporting Formats include 3 1 4 1 4 2 Standard Expanded 4 1 4 2 Ademco Express battery charger for up to 60 hours of standby Fuseless power limited technology meets UL power lim requirements Programmable Alarm Presignal Timer Alarm Verification and Optional Trouble Reminder Single person walk test Fire drill function Zone disable capability software 32 Event history buffer with time and date stamp Accurate real time clock Extensive built in transient protection Electronics and operational controls fully enclosed in lock cabinet capable of housing batteries up to 7 AH 230 VAC 50 Hz international version available Alarms is a Honeywell company document is not intended to be used for installation purposes We try to keep product information up to date and accurate We cannot cover all specific or anticipate all requirements All specifications are subject to without notice more information contact Fire cid 127 Lite Alarms One Fire Lite Place Northford 06472 Phone 800 627 3473 Toll Free FAX 877 699 4105 in the U S A 07 12 04 Page 1 of 3 cabinet is red with a dark blue overlay Knockouts on top sides and back provide ease of wire entry The can be surface or semi flush mounted and is com in design high x 12.75 wide cm high x 32.385 cm wide 14.5 high x 12.5 wide x 3.0 deep cm high x 31.75 cm wide x 7.62 cm Ring Part TR 3 R high x 15.625 wide cm high x 39.688 cm wide Five zone 24 volt Fire Alarm Control Commu Includes backbox transformer techni manual and a frame post operating in sheet Same as above with 230 VAC 50 Hz trans UL Listed Remote Annunciator mounts to a box requires ADM 24 Annunciator Driver Module Class A Converter Module Converts all Class Initiating Device Circuits zones to Class A Class A Converter module Converts both Class Notification Appliance Circuits NAC to Class Internal Dress Panel DACT phone cord 7 feet long two required UL listed battery backbox Required for batter over 7 AH ring Battery 12 volt 4.2 AH two required Battery 12 volt 7.0 AH two required Battery 12 volt 12.0 AH two required requires Battery 12 volt 17.0 AH two required requires backbox backbox Replacement motherboard Single PC board design using Surface Mount Technol Two modular telephone jacks for connection to RJ31X SMT 120 VAC 50 60 Hz 1.3 amps 230 VAC 50 Hz 0.68 amps suffix Wire size minimum 14 AWG 2.0 mm with 600 volt in Built in brownout circuitry Built in voltmeter One line active indicator for each of two phone lines signal LED Dual telephone voltage detect circuitry Programmable event codes per each format Up to 58 transmitted events messages Selectable deselectable transmissions of 58 events Five zones may be configured to five channels as a slave channels are auto resettable formats allow complete transaction to be commu in under five seconds 20 PPS 3 1 standard and expanded 20 PPS 4 1 standard and expanded 20 PPS 4 2 standard and expanded 4 1 and 4 2 Ademco Express MS 5024 includes five programmable Initiating Device zones Circuits 1 2 4 and 5 are Style B Class Circuit 3 is Style D Class A Use the CAC 5F Class A module to convert all Class B IDCs to Class A zone may support two wire smoke detectors Pro options include Waterflow Silenceable Non Silenceable Supervisory Standard Auto Reset Pull Station Normally Open Contact device circuits are power limited and also fully supervised They up to 100 ohms of line resistance and allow for use of to 18 AWG 3.1 to 0.78 mm wire Two Style Y Class B 1.5 amps each All circuits are fully power limited and meet UL power requirements using fuseless technology Resettable four wire smoke detector power 300 mA Non resettable power 300 mA Use of auxiliary power outputs does not derate avail 3 amps of NAC power Two fully programmable Form C relays 2 of 3 DF 51267 cid 127 07 12 04 cid 22 cid 29 cid 21 cid 22 cid 11 cid 10 cid 12 cid 13 cid 14 cid 15 cid 16

Related Files