Fire-Lite MS-5210UD Fire Alarm Control Panel with Built-in DACT and Remote-Site Upload Download Capability

File Preview
File Preview
Click below to download for free

Text Preview

GENERAL Fire MS 5210UD is a 24 volt ten zone fire alarm panel with built in communicator and remote site capability requires panel software revi MS52103.0 or greater The integral communicator event information alarms troubles supervi faults etc to a UL listed central station Select transmission formats allow the MS 5210UD to com to virtually all central stations Ten programmable Initiating Device Circuits zones zone may be programmed for Two wire smoke detectors N O contact devices pull heat Four wire smoke detectors Waterflow operation silenceable or nonsilenceable Supervisory operation Auto reset supervisory operation Remote switch for Reset Drill Silence and Acknowl Auto reset or latching critical and noncritical process Zones programmed for process monitoring require a closure for activation and can be used to monitor Temperature high low temp Water level Refrigeration Gas detection Tamper non fire Loss of air flow Open Close Two built in Class B Style Y Notification Appliance NACs expandable to four Notification Appliance Circuits may be programmed Silenceable Non Silenceable a strobe circuit can keep flashing the panel is silenced Auto Silence program 5 to 30 minutes Silence Inhibit 60 seconds Coding March Time Temporal California 3.0 Amps of Notification Appliance power expandable to amps meets the critical power requirements for ADA UL 1971 devices Two built in fully programmable Form A relays expand to four with two Form C relays Dual line rotary or Touch Tone DACT interfaces to telephone network leased phone lines are not 24 Volt operation 12 2004 A3 400 Alarm Control Panel with built in DACT Alarm Control Panel with built in DACT Alarm Control Panel with built in DACT Alarm Control Panel with built in DACT Alarm Control Panel with built in DACT remote site Upload Download capability remote site Upload Download capability remote site Upload Download capability remote site Upload Download capability remote site Upload Download capability Control Communicators Fire MS 5210UD Built in voltmeter measures Zone voltage Primary AC line voltage Battery voltage Notification Appliance Circuit s voltage Resettable 24 volt power Surface Mount Technology SMT Fully programmable via built in keypad no costly exter programmers necessary Complies with NFPA 72 Local Central Station and Station DACT only not polarity reversal Fire Systems Reporting Formats include Ademco Contact ID and 14 Integral battery charger for up to 60 hours of standby Fuseless power limited technology meets new UL power requirements effective May 1 1995 Programmable Alarm Presignal Timer Alarm Verifica Timer and Optional Trouble Reminder Single person walk test with 256 event walk test buffer Fire drill function Zone disable capability software 256 Event history buffer with time and date stamp stored permanent memory Accurate real time clock calendar document is not intended to be used for installation purposes We try to keep product information up to date and accurate We cannot cover all specific or anticipate all requirements All specifications are subject to change notice For more information contact Fire Alarms One Fire Lite Place Connecticut 06472 Phone 800 627 3473 Toll Free FAX 877 699 4105 www firelite com in the U S A 07 12 04 Page 1 of 3 Electronics and operational controls fully enclosed in a cabinet capable of housing up to 12 AH batter Optional LED 10 Series Remote Annunciators operate serial two wire EIA 485 interface Optional contact by zone module and printer interface on or off line printing 230 VAC 50 Hz international version available SITE UPLOAD DOWNLOAD SITE UPLOAD DOWNLOAD SITE UPLOAD DOWNLOAD SITE UPLOAD DOWNLOAD SITE UPLOAD DOWNLOAD MS 5210UD may be downloaded or uploaded requires software revision MS52103.0 or greater without the system fire protection at the protected Download system programming Upload key system information Current system status history walk test files Zone AC line NAC1 2 3 and 4 resettable power battery voltages System programming Upload or download within one minute without affecting fire panel functions Multiple security techniques Requires PK 5210UD programming kit which works with Hayes compatible modems consult factory for list PC board design using Surface Mount Technology Two modular telephone jacks for connection to Power Power Power Power Power 120 VAC 50 60 Hz 2.3 amps 230 VAC 50 Hz 1.2 amps suffix Wire size minimum 14 AWG with 600 volt insulation Built in brownout circuitry Built in voltmeter One line active indicator for each of two phone lines signal LED Dual telephone voltage detect circuitry Programmable event codes per each format Up to 100 transmitted events messages Selectable deselectable transmissions of 100 events Formats Formats Formats Formats Formats and Ademco Contact ID formats allow complete to be communicated in under five seconds Ademco Contact ID 20 PPS 3 1 standard and expanded 20 PPS 4 1 standard and expanded 20 PPS 4 2 standard and expanded 4 1 and 4 2 Ademco Express DEVICE CIRCUITS ZONES DEVICE CIRCUITS ZONES DEVICE CIRCUITS ZONES DEVICE CIRCUITS ZONES DEVICE CIRCUITS ZONES MS 5210UD includes ten programmable Class B Initi Device Circuits zones Use the CAC 10F Class A module to convert all Class B IDC to A zone may support two wire smoke detectors Pro options include Normally Open Contact devices pull heat Four wire smoke detectors 2 of 3 DF 51492 07 12 04 Waterflow silenceable non silenceable operation Supervisory standard auto reset operation Remote switch for Reset Drill Silence Acknowledge Critical and Noncritical Process Monitoring standard circuits are power limited and fully supervised They up to 100 ohms of line resistance and allow for use of to 18 AWG wire APPLIANCE CIRCUITS APPLIANCE CIRCUITS APPLIANCE CIRCUITS APPLIANCE CIRCUITS APPLIANCE CIRCUITS Two Style Y Class B 3.0 amps each Use the CAC Class A Converter Module to convert all Class B and IDC to Class A Option module adds two Style Z Class A NACs 1.5 each All circuits are fully power limited and meet the new UL requirements effective May 1 1995 using technology OUTPUTS OUTPUTS OUTPUTS OUTPUTS OUTPUTS Resettable four wire smoke detector power 500 mA Non resettable power 500 mA Two fully programmable Form A B relays Option module adds two fully programmable Form C DEVICES EIA 485 PORT DEVICES EIA 485 PORT DEVICES EIA 485 PORT DEVICES EIA 485 PORT DEVICES EIA 485 PORT EIA 485 Interface Module Provides MS with EIA 485 output capable of supporting up to compatible EIA 485 devices listed belo

Related Files