Fire-Lite MS 5210UD Operating Instructions Frame and Post
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-ms-5210ud-operating-instructions-frame-and-post-1054276398.pdf |
---|---|
Type | |
Size | 600.79 KB |
Downloads |
Text Preview
MS 5210UD Control Communicator Only the GREEN A C POWER LED is on All LEDs are off The key to open the panel can be found at this AUDIBLE DEVICES ARE SOUNDING AN ALARM the protected area the monitoring service and or the Fire Department Tell them briefly what happened and what your status is the Fire Department is responding be prepared to provide to arriving firefighters TROUBLE ONLY the monitoring service and or Fire Department if this is connected to either one and tell them what is audible devices by pressing the SILENCE key The SYSTEM TROUBLE LED will remain on Contact service personnel immediately return to normal after an alarm not enter the protected area until safe to do so all initiating devices Smoke detectors will not reset if is still smoke in the area the control panel press the RESET key failure or brownout AC POWER LED will go out for AC or brownout and the TROUBLE LED will come on SYSTEM LED and the panel buzzer will turn on for either and any other audible trouble devices will sound authorized service personnel immediately to Local Service Representative block below Silencing Alarm Signaling Circuits may be silenced by the SILENCE key The SILENCE LED will turn on alarms will reactivate circuits Press the RESET to clear the silenced condition ALARM SILENCE may be disallowed for one minute if see manual WARNING not allow trouble conditions to remain logged the system Protection that the system offers been compromised or eliminated when a condition exists Operating Instructions Zone n 1 10 Loss Appliance Circuit Fault n 1 4 Disabled n 1 4 Disabled n 1 10 Drill Enabled n 1 10 Bus Fault Fault Fault Zone n 1 10 Fault Battery Battery Phone Line Voltage Low Phone Line Voltage Low Number Communications Fault Number Communications Fault Monitoring Alarm Zone Reset Silenced n 1 4 Alarm Zone n n 1 10 n bn n n 85 A E n P b b 1 2 1 2 n n clear alarm indications in panel after cause alarm has been corrected press turn off the local panel sounder and notification appliance circuits perform a fire drill press RESET key restores the panel to normal test the lamps press to the MS 5210UD Technical Manual 50193 for more details Service Representative and mount adjacent to the control panel 50448 Rev A ECN 96 073 2 28 96