U5015 Smoke Detector U5015 Explosion Proof Smoke Detector has Division and explosion proof ratings and is suitable for industrial and applications The detector is designed to operate with smoldering and rapidly growing fires and con the ability to annunciate fault ensuring no undisclosed The U5015 Smoke Detector outputs include 0 20 mA localized LED and relays Zone approved Trouble free photoelectric operation 0 20 mA output for DCS integration Self checking circuitry ensures reliable smoke detection Alarm Auxiliary and Fault relays for controlling annunciat devices or fire panel interface LED provides a visual indication that an alarm has occurred ingress protection level suitable for onshore or off requirements suited for classified areas in the petrochemical oil gas industry DCS PLC integration with milliamp or relay outputs Rugged design for environmental extremes Visual confirmation of detector alarm Detects smoldering fires No undisclosed failures Combustible storage facilities Munitions manufacturing Volatile chemical storage Chemical processing plants Petroleum refineries Turbine enclosures Battery rooms HVAC applications hot swappable sensor module is intrinsically safe and live maintenance while under power without de classi the hazardous area The integrated junction box is avail in a variety of port configurations for simplified wiring and Approved Class 1 Div 1 Groups B C D T4 Class 1 Div 2 Groups A B C D T4 Class 1 Zone1 AWX db ia llC T4 Gb FMG 15.0014X Ex db ia llC T4 Gb F 920 Initiating Devices Mount Mount celing jpg Consumption 3.5 watts maximum 2.75 watts at 24 Relays Smoke alarm relay Form C 5 amperes at 30 VDC The alarm relay has normally open normally closed con and normally de energized operation Fault relay Form A 5 amperes at 30 VDC The fault relay normally open contacts and normally energized opera Auxiliary relay Form C 5 amperes at 30 VDC The auxiliary has normally open normally closed contacts and nor de energized operation Range Operating to 65 to 149 Storage to 70 to 158 Range 5 to 95 relative humidity Protection IP44 Applicable to ceiling mount only Output 0 20 mA mA DC current with maxi loop resistance of 300 ohms from 12 17.9 VDC 500 from 18 to 19.9 VDC and 600 ohms from 20 30 VDC UL CSA rated for 14 18 AWG or 2.5 0.75 mm2 Options 3 4 inch NPT or M25 Multi port models avail Material Polycarbonate ABS Smoke Detector aluminum painted Junction Box Weight Approximate 7.85 lbs 3.56 kg Period 1 year 03 11 2016 Page 1 of 2 Alarms is a registered trademark of Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Fire Alarms Phone 800 627 3473 FAX 877 699 4105 in the U S A 2 of 2 DF 60908 A 03 11 2016