Fire-Lite MS-5UD-3 MS-10UD-7(E)

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-ms-5ud-3-ms-10ud-7-e-5304167928.pdf
Type PDF
Size 729.75 KB
Downloads

Text Preview

MS 5UD 3 MS 10UD 7 E Zone Fire Alarm Control Panel Zone Fire Alarm Control Panel MS 5UD 3 is a five zone FACP Fire Alarm Control Panel the MS 10UD 7 E is a ten zone FACP These control pan provide reliable fire signaling protection for small to commercial industrial and institutional build Both panels include built in communicators for Central Service and remote upload download of these FACPs is compatible with System Sensor i3 series detectors These conventional detectors can transmit a maintenance trouble signal to FACP indicating the need for cleaning and a supervisory signal when the ambient temperature falls below the rating Additionally both the MS 5UD 3 and MS are compatible with conventional input devices such two and four wire smoke detectors pull stations waterflow tamper switches and other normally open contact Refer to the Fire Device Compatibility Document a complete listing of compatible devices include four NACs Notification Appliance Circuits programmable Form C relays factory programmed for Trouble and Supervisory and 24 VDC special applica resettable and nonresettable power outputs The FACPs all wiring AC voltage battery level and telephone integrity of a compatible smoke detector or any normally fire alarm initiating device will activate audible and visual devices illuminate an indicating LED sound the sounder at the FACP activate the communicator and alarm relay and operate an optional module used to a remote station or initiate an auxiliary control function options include a UL listed printer PRN 6F and FireLite IPDACT Internet Monitoring module The IPDACT permits of alarm signals over the Internet saving the cost of two dedicated business telephone lines not required the secondary telephone line may be providing backup communication over the public telephone line The MS 10UD 7E offers the same features as the MS but allows connection to 240 VAC Unless otherwise the information in this data sheet applies to both the 120 and the 240 VAC versions of these panels Listed to UL Standard 864 9th edition Built in DACT Digital Alarm Communicator Transmitter Style B Class B IDC Initiating Device Circuit MS 5UD 3 five IDCs MS 10UD 7 ten IDCs application power MS 5UD 3 four NACs MS 10UD 7 four NACs Notification Appliances may be programmed as Silence Inhibit Auto Silence Strobe Synchronization for System Sensor Wheelock Faraday or Amseco devices cid 129 A3 20 Selective Silence horn strobe mute Temporal or Steady Signal Silenceable or Nonsilenceable Optional CAC 5X Style Z Class A Converter Module for and IDCs 2 required for MS 10UD 7 Form C Relays for Alarm Trouble and Supervisory Con Ratings 2.0 A 30 VDC or 30 VAC resistive 3.0 A total system current for MS 5UD 3 7.0 A total system current for MS 10UD 7 Optional Dress Panel DP 51050 Optional Trim Ring TR CE for semi flush mounting 24 volt operation Low AC voltage sense Alarm Verification PAS Positive Alarm Sequence Automatic battery trickle charger Up to eight ANN BUS annunciators Optional 8 zone Relay Module ANN RLY Optional LED Annunciator Module ANN LED Optional Remote Annunciator ANN 80 Optional Remote Printer Gateway ANN S PG Optional LED Annunciator Driver ANN I O Optional 4XTMF module conventional reverse polarity city AND SOFTWARE Can be programmed at the panel with no special software additional equipment Programmable Make Break Ratio Upload Download local or remote of program and data via DACT 07 10 08 Page 1 of 4 Style Y Class B NAC Notification Appliance Circuit spe transmitter INTERFACE Built in DACT Digital Alarm Communicator Transmitter 80 character LCD display with backlighting and Real time clock calendar with automatic daylight savings ANN BUS for connection to remote annunciators Audible or silent walk test capabilities Piezo sounder for alarm trouble and supervisory and Indicators INDICATORS FIRE ALARM red SUPERVISORY yellow TROUBLE yellow AC POWER green ALARM SILENCED yellow BUTTONS ACKNOWLEDGE ALARM SILENCE SYSTEM RESET lamp test DRILL Blocks Power TB1 MS 5UD 3 FLPS 3 Power Supply 120 VAC 50 60 HZ A A A MS 10UD 7 FLPS 7 Power Supply 120 VAC 50 60 HZ MS 10UD 7E FLPS 7 Power Supply 240 VAC 50 HZ size minimum 14 AWG 2.00 mm with 600 V insulation nonpower limited sealed lead acid only J12 Maximum Charging Circuit Normal Flat Charge 27.6 VDC 1.4 A Supervised nonpower limited Maximum Charger Capacity 18 AH battery for MS 5UD 3 26 AH battery for MS 10UD 7 E Two 18 Ah batteries be housed in the FACP cabinet Larger batteries separate battery box such as the BB 26 or BB 55 Minimum Battery Size 7 AH Measurements 2 of 4 DF 52416 B cid 129 07 10 08 Device Circuits TB4 and TB 6 on MS 10UD 7 Alarm Zones 1 5 on TB 4 MS 5UD 3 and MS 10UD 7 Alarm Zones 6 10 on TB6 MS 10UD 7 only Supervised and power limited circuitry Operation All zones Style B Class B Normal Operating Voltage Nominal 20 VDC Alarm Current 15 mA minimum Short Circuit Current 40 mA max Maximum Loop Resistance 100 ohms End of Line Resistor 4.7K ohm 1 2 watt P N 71252 UL Standby Current 2 mA to the Fire cid 129 Lite Device Compatibility Document for listed devices Appliance Circuits TB5 and TB 7 on MS only Four NACs Operation Style Y Class B Special Application power Supervised and power limited circuitry Normal Operating Voltage Nominal 24 VDC Maximum Signaling Current 3.0 A for MS 5UD 3 2.5 A per NAC 7.0 A for MS 10UD 7 E 3.0 A maxi per NAC End of Line Resistor 4.7K ohm 1 2 watt Part 71252 Max Wiring Voltage Drop 2 VDC to the Fire cid 129 Lite Device Compatibility Document for com listed devices C Relays TB8 Relay 1 factory default programmed as Alarm Relay Relay 2 factory default programmed as fail safe Trouble Relay 3 factory default programmed as Supervisory Relay Application Resettable Power TB9 Jumper selectable by JP31 for resettable or nonresettable Operating voltage 24 VDC nominal Maximum available current 500 mA appropriate for pow four wire smoke detectors Power limited circuit to the Fire cid 129 Lite Device Compatibility Document for listed devices Sync Output TB2 Remote power supply synchro output only required for the MS 5UD 3 24 VDC nom special application power Maximum current is 40 mA Resistor 4.7K ohm Supervised and power lim circuit Information Five zone 24 volt Fire Alarm Control Panel backbox FLPS 3 power supply technical manual a frame post operating instruction sheet Ten zone 24 volt Fire Alarm Control Panel backbox FLPS 7 power supply technical manual a frame post operating instruction sheet Same as above with 240 VAC FLPS 7 Internet monitoring module Mounts in bottom of with optional mounting kit PN IPBRKT Connects primary and secondary DACT telephone output ports for communications over customer provided ethernet connection Requires compatible Teldat Visoralarm Station Receiver Can use DHCP or static IP See sheet df 52424 for more information Mounting kit for IPDACT in common enclosure Y Adaptor option to allow connection of both panel outputs to one cable input to IPDACT sold sepa

Related Files