Fire-Lite MS-9200 198-Point Intelligent Control Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-ms-9200-198-point-intelligent-control-data-sheet-3957614082.pdf |
---|---|
Type | |
Size | 980.49 KB |
Downloads |
Text Preview
January 28 2005 cid 127 A1 100 Fire Alarm Control P Fire Alarm Control P Fire Alarm Control Panel Fire Alarm Control P Fire Alarm Control P Addressable Fire Fuseless power limited technology meets UL power lim requirements Detector sensitivity printout requires v2.1 software Presignal delay option per NFPA 72 Rapid poll algorithm for manual stations Responds to in less than two seconds Operates with untwisted unshielded wire up to 1,000 ft m for retrofit applications U S Patent 5,210,523 300 Series addressable devices feature decimal address Address of each device can be easily set in the by use of a screwdriver UDACT F Digital Alarm Communicator reports 56 zones 198 points to a Central Station Built in printer interface UL listed for permanent attach LCD 40 Series alphanumeric 40 character backlit remote annunciators operate over built in high speed EIA port Up to 32 may be supported on the MS 9200 re software P N 73750 or greater Fire MS 9200 is a compact cost effective addres fire alarm control panel with a capacity of 198 Fire cid 127 Lite Series devices A single Signaling Line Circuit SLC supports up to 99 smoke detectors and 99 control or modules The panel uses surface mount technology is designed for ease of installation and programming It the latest in fire protection technology including alert and automatic detector test Its new larger is capable of housing 12.0 AH batteries MS 9200 includes on the motherboard rev PC D built interfaces for a printer and remote annunciators on pan manufactured after September 1 2001 Loop SLC can be configured for NFPA Style 4 6 or 7 opera SLC supports up to 198 addressable devices 99 detec and 99 monitor or control modules including new ad dual monitor module SLC loop maximum length 10,000 ft 3,048 m 12 AWG mm Appliance Circuits NACs Dual Integral NACs Style Y or Z Class B or A Silence Inhibit and Auto Silence timer options Alarm trouble and supervisory relays standard May be programmed for Steady March Time Temporal or code requires software P N 73750 or greater 3.0 amp NAC power expandable to 6.0 amps and Software Autoprogram and Walk Test features identify two or more set to same address Keypad programmable on panel with two user defined plus an Autoprogram feature Custom English labels per point may be manually entered selected from an internal library file Remote Acknowledge Silence Reset and Drill via MMF modules and LCD 40 remote annunciators Interface 40 character LCD display with backlighting Real time clock calendar History file with 500 event capacity Fire Technology Maintenance alert warns when smoke detector dust accu is excessive Battery charger for up to 60 hours of standby power Waterflow or supervisory selection per monitor point System alarm verification selection smoke only Alarms is a Honeywell company document is not intended to be used for installation purposes We try to keep product information up to date and accurate We cannot cover all specific or anticipate all requirements All specifications are subject to change notice more information contact Fire cid 127 Lite Alarms One Fire Lite Place Northford 06472 Phone 800 627 3473 Toll Free FAX 877 699 4105 in the U S A DF 51276 01 28 05 Page 1 of 4 PERIPHERALS AND WIRING PERIPHERALS AND WIRING PERIPHERALS AND WIRING PERIPHERALS AND WIRING PERIPHERALS AND WIRING 1 suffix should be included when ordering Canadian 300 Series devices suffix designates Canadian version MS 9200 LCD 40 and printer option cannot be used simultaneously REQUIREMENTS REQUIREMENTS REQUIREMENTS REQUIREMENTS REQUIREMENTS SLC requires use of a specific wire type to ensure proper circuit operation It is that all SLC wiring be twisted pair shielded to minimize the effects of interference Wire size should be no smaller than 18 AWG 0.78 mm2 and larger than 12 AWG 3.1 mm2 wire wire size depends on the length of the SLC circuit Use the table below to deter the specific wiring requirements for the SLC shielded shielded shielded shielded Feet m feet m feet m feet m feet m feet m Wire Size AWG 3.1 mm Belden 9583 Genesis 4410 98230 WPW D999 AWG 2.00 mm Belden 9581 Genesis 4408 98430 WPW D995 AWG 1.3 mm Belden 9575 Genesis 4406 4606 Signal 98630 WPW D991 AWG 0.78 mm Belden 9574 Genesis 4402 4602 Signal 98300 WPW D975 unshielded 18 AWG 3.1 0.78 mm 2 of 4 DF 51276 cid 127 01 28 05 ADDRESSABLE DEVICES ADDRESSABLE DEVICES ADDRESSABLE DEVICES ADDRESSABLE DEVICES ADDRESSABLE DEVICES feature a polling LED and rotary address switches Addressable ionization smoke detector Addressable photoelectric smoke detector with thermal sensor Addressable duct detector R with re Addressable monitor module for one zone of nor dry contact initiating devices Mounts in standard 10.16 cm box Includes plastic cover plate and end of resistor Module may be configured for either a Style B B or Style D Class A initiating device circuit Dual monitor module Same as MMF 300 except operates in Style B Class B only Provides two Class B Miniature version of MMF 300 Excludes LED and D option Connects with wire pigtails May mount in backbox Similar to MMF 300 but may monitor up to 20 two wire detectors Requires external 24 VDC Consult factory for compatible smoke detectors Addressable control module for one Style Y Z B A zone of supervised polarized Notification Appli Mounts directly to a 4 10.16 cm electrical box Appliance Circuit option requires external 24 VDC power notification appliances Addressable relay module containing two isolated of Form C contacts which operate as a DPDT switch directly to a 4 10.16 cm box surface mount using SMB500 Ten input monitor module Mount one or two in a BB 2F cabinet optional Mount up to six modules a CHS 6 chassis in a BB 6F Six zone interface module Mount one or two in a BB 2F cabinet optional Mount up to six modules a CHS 6 chassis in a BB 6F Six circuit supervised control module Mount one two modules in a BB 2F cabinet optional Mount up to six on a CHS 6 chassis in a BB 6F Six Form C relay control module Mount one or modules in a BB 2F cabinet optional Mount up to six on a CHS 6 chassis in a BB 6F This module isolates the SLC loop from short circuit required for Style 7 operation Addressable manual pull station with interface mounted inside with legacy Fire 300 Series devices Please factory for further information on all the previous 300 Series CP300 CP350 SD300 T SD350 T D350P D350RP M300 M301 M302 C304 and BG 10LX NOTES 1 should be included only when ordering ULC listed units e g MMF 300A 2 For more on MS 9200 Compatible Ad Devices please see the following data sheets docu numbers SD355 SD355T DF 52384 CP355 DF 52383 DF 52176 MMF 300 Series MDF 300 Moni Modules DF 52121 MMF 300 10 DF 52347 MMF 302 6 DF CMF 300 6 DF 52365 CRF 300 6 DF 52374 I300 DF and BG 12LX DF 52013 PORT PORT PORT PORT PORT Printer PC interface module cable DB9F connec and 9 pin male to 25 pin female adapter LCD 40 display inter