Fire-Lite MS-9200UDLS(E)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-ms-9200udls-e-4719506382.pdf |
---|---|
Type | |
Size | 717.63 KB |
Downloads |
Text Preview
MS 9200UDLS E Addressable FACP Built In Communicator Fire cid 129 Lite MS 9200UDLS is a combination FACP Fire Control Panel and DACT Digital Alarm Communicator all on one circuit board This compact cost effec intelligent addressable control panel has an extensive list powerful features the MS 9200UDLS may be used with an SLC configured the CLIP Classic Loop Interface Protocol mode it can also in LiteSpeed mode latest polling tech a quicker device response time LiteSpeed pat technology polls 10 devices at a time This improvement a fully loaded panel with up to 198 devices to report an and activate the notification circuits in under 10 sec With Litespeed polling devices can be wired on stan twisted unshielded wire up to a distance of 10,000 feet the wire table on page 3 for specific installation MS 9200UDLS quick remove chassis protects the elec during construction The backbox can be installed field wiring to be pulled When construction is com the electronics can be quickly installed with just two accessories include LED graphic and LCD annunci and reverse polarity city box transmitter integral DACT transmits system status alarms superviso troubles AC loss etc to a Central Station via the public telephone network It also allows remote and local of the control panel using the PK CD Upload utility In addition the control panel may be pro or interrogated off site via the public switched tele network Any personal computer with Windows 95 or a compatible modem and PK CD the Fire cid 129 Lite software kit may serve as a Service Termi This allows download of the entire program or upload of entire program history file walktest data current status system voltages The panel can also be programmed the FACP keypad or via a standard PS 2 computer which can be plugged directly into the printed circuit This permits easy typing of address labels and other information options include a UL listed printer PRN 6F and FireLite IPDACT Internet Monitoring module The IPDACT permits of alarm signals over the Internet saving the cost of two dedicated business telephone lines not required the secondary telephone line may be providing backup communication over the public telephone line Unless otherwise specified the term MS 9200UDLS is in this document to refer to both the MS 9200UDLS and the FACPs Fire Alarm Control Panels Listed to UL standard 864 9th edition On board DACT Remote site or local upload download using PK CD Four Style Y Class B or two Class A Style Z NAC cir cid 129 A1 40 6.0 amps total NAC power with optional XRM 24 Selectable strobe synchronization for System Sensor and Gentex devices Remote Acknowledge Silence Reset and Drill via address monitor modules Up to 32 ACM Series ACM 16AT or ACM 32 series or LCD 80F remote annunciators via EIA 485 EIA 232 printer PC interface variable baud rate on main board for use with optional UL listed printer PRN 6F 80 character LCD display with backlighting Real time clock calendar with automatic daylight savings Detector sensitivity test capability NFPA 72 compliant History file with 1,000 event capacity Maintenance alert warns when smoke detector dust accu is excessive Automatic device type code verification One person audible or silent walk test with walk test log and Point trouble identification Waterflow nonsilenceable selection per monitor point System alarm verification selection per detector point PAS Positive Alarm Sequence and presignal delay per NFPA 72 compliant LOOP SLC can be configured for NFPA Style 4 6 or 7 operation SLC supports up to 198 addressable devices per loop 99 and 99 monitor control or relay modules 07 28 08 Page 1 of 4 SLC loop maximum length 10,000 ft 3,000 m wire table on page 3 APPLIANCE CIRCUITS NACS Four onboard NACs with additional NAC capability using control modules CMF 300 or CMF 300 6 Silence Inhibit and Auto Silence timer options Continuous March Time Temporal or California code for circuit board NACs with two stage capability Selectable strobe synchronization per NAC 2.5 amps maximum per each NAC circuit Maximum or total 24VDC system power shared between NAC circuits and auxiliary power outputs is 3.6 amps AND SOFTWARE Autoprogram learn mode reduces installation time Custom English labels per point may be manually entered selected from an internal library file Two programmable Form C relay outputs 99 software zones Continuous fire protection during online programming at the panel Program Check automatically catches common errors not to any zone or input point OFFLINE PROGRAMMING Create the entire program in office using a Windows software package programming kit PK CD containing PK Plus sepa Upload download system programming locally to MS 9200UDLS E in less than one minute interface INDICATORS AC Power green Fire Alarm red Supervisory yellow Alarm Silenced yellow System Trouble yellow Maintenance Presignal yellow Disabled yellow Battery Fault yellow Ground Fault yellow CONTROLS Acknowledge Step Alarm Silence Drill System Reset lamp test 16 key alpha numeric pad similar to telephone keypad 4 cursor keys Enter Options addressable Fire Alarm Control one SLC loop Includes 80 character LCD display sin printed circuit board mounted on chassis and cabinet 120 operation Same as MS 9200UDLS except with 240 operation Reverse Polarity Transmitter Module Provides output for local energy municipal box transmitter and trouble Contains PK Plus programming software for Win PC computer cable not included Optional dress panel for MS 9200UDLS 2 of 4 DF 52422 B cid 129 07 28 08 Trim Ring for semi flush mounting Battery backbox holds up to two 25 AH batteries and Battery box houses two 55 AH batteries Battery charger for lead acid batteries with a rating 25 to 75 AH Remote battery charging system for lead acid bat with a rating of 55 to 120 AH Requires additional BB for mounting Series Batteries see data sheet DF 52397 Optional transformer Increases system power to amps Use XRM 24E with MS 9200UDLS E Cable printer personal computer interface required for printer or for local upload download pro UL listed compatible event printer Uses tractor fed Internet Monitoring Module Mounts in bottom of with optional mounting kit PN IPBRKT Connects primary and secondary DACT telephone output ports for communications over customer provided ethernet connection Requires compatible Teldat Visoralarm Station Receiver Can use DHCP or static IP See sheet df 52424 for more information Mounting kit for IPDACT in common enclosure Y adaptor option allows connection of both panel outputs to one IPDACT cable input ANNUNCIATORS Relay module provides 8 Form C 5.0 amp relays Zone Series LED type fire annunciators capable of up to 99 software zones of annunciation Available in of 16 or 32 points to meet a variety of applications Graphic Series Lamp Driver Module series for use with graphic annunciators Liquid Crystal Display point annunciator backlit LCD type fire annunciators capable of English language text For more information on Compatible Annunciators for use the MS 9200UDLS see the following data sheets document ACM 8RFACM 8R DF 51555 ACS ACMSeries DF LDM Series DF 51384 LCD 80F DF 52185 COMPATIBLE ADDRESSABLE DEVICES feature a polling LED and rotary switches for addressing Addressable low pro