Fire-Lite MS-9200UDLS(E) REV 2 Intelligent Addressable FACP with Built-In Communicator
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-ms-9200udls-e-rev-2-intelligent-addressable-facp-with-built-in-communicator-2843679501.pdf |
---|---|
Type | |
Size | 1007.35 KB |
Downloads |
Text Preview
MS 9200UDLS E Rev 2 Addressable FACP Built In Communicator Fire cid 129 Lite MS 9200UDLS Rev 2 with Version 4.0 firmware a combination FACP Fire Alarm Control Panel and DACT Alarm Communicator Transmitter all on one circuit This compact intelligent addressable control panel has extensive list of powerful features the MS 9200UDLS Rev 2 may be used with an SLC in the CLIP Classic Loop Interface Protocol mode can also operate in LiteSpeed mode latest technology a quicker device response time patented technology polls 10 devices at a time improvement allows a fully loaded panel with up to 198 to report an incident and activate the notification cir in under 10 seconds With Litespeed polling devices can wired on standard twisted unshielded wire up to a distance 10,000 feet MS 9200UDLS Rev 2 quick remove chassis protects the during construction The backbox can be installed field wiring to be pulled When construction is com the electronics can be quickly installed with just two accessories include ANN BUS devices as well as LED graphic and LCD annunciators and reverse polar box transmitter integral DACT transmits system status alarms superviso troubles AC loss etc to a Central Station via the public telephone network It also allows remote and local of the control panel using the PS Tools Upload utility In addition the control panel may be pro or interrogated off site via the public switched tele network Any personal computer with Windows XP or a compatible modem and PS Tools the Fire cid 129 Lite software kit may serve as a Service Termi This allows download of the entire program or upload of entire program history file walktest data current status system voltages The panel can also be programmed the FACP keypad or via a standard PS 2 computer which can be plugged directly into the printed circuit This permits easy typing of address labels and other information 4.0 firmware supports the following ANN bus devices LiteSpeed USB port NAC circuit diagnostics a new has been added to the walk test that lists untested new device types added audio telephone type code ACC 25 50ZST Photo Supervisory and auto resettable non latching FireWatch Series internet monitoring modules IPDACT 2 IPDACT 2UD permit monitoring of alarm signals over the saving the monthly cost of two dedicated business lines Although not required the secondary tele line may be retained providing backup communication the public switched telephone line Unless otherwise specified the term MS 9200UDLS is in this document to refer to both the MS 9200UDLS and the FACPs Fire Alarm Control Panels Listed to UL standard 864 9th edition On board DACT Remote site or local USB port upload download using PS Four Style Y Class B or two Class A Style Z NAC cir Up to 6.0 amps total NAC power when using XRM 24B Selectable strobe synchronization for System Sensor and Gentex devices Remote Acknowledge Silence Reset and Drill via address monitor modules or LCD 80F ANN 80 or ACS Annun ANN BUS for connection to following optional modules cannot used if ACS annunciators are used ANN 80 W Remote LCD Annunciator ANN I O LED Driver ANN S PG Printer Module ANN RLY Relay Module ANN LED Annunciator Module ANN RLED Annunciator Module alarms only ACS TERM ACS Annunciators Up to 32 ACM Series annunciators or ACM 32 series Cannot be used if ANN devices are used Terminal mode Annunciators Up to 32 LCD 80F remote EIA 232 printer PC interface variable baud rate on main board for use with optional UL listed printer PRN 6F 80 character LCD display with backlighting 12 17 2009 Page 1 of 6 Real time clock calendar with automatic daylight savings Detector sensitivity test capability NFPA 72 compliant History file with 1,000 event capacity Maintenance alert warns when smoke detector dust accu is excessive Automatic device type code verification One person audible or silent walk test with walk test log and Point trouble identification Waterflow nonsilenceable selection per monitor point System alarm verification selection per detector point PAS Positive Alarm Sequence and presignal delay per NFPA 72 compliant Only detectors may participate in PAS LOOP SLC can be configured for NFPA Style 4 6 or 7 operation SLC supports up to 198 addressable devices per loop 99 and 99 monitor control or relay modules SLC loop maximum length 10,000 ft 3,000 m installation manual for wire tables APPLIANCE CIRCUITS NACS Four onboard NACs with additional NAC capability using control modules CMF 300 or CMF 300 6 The four B NACs can be converted to two Class A NACs with included Silence Inhibit and Auto Silence timer options Continuous March Time Temporal or California code for circuit board NACs with two stage capability Selectable strobe synchronization per NAC 2.5 amps maximum per each NAC circuit Maximum 24VDC system power output is shared among NAC circuits and 24VDC special application auxiliary power Total available output is 3.0 amps Using the optional transformer increases 24VDC output to 6.0 amps AND SOFTWARE Autoprogram learn mode reduces installation time Custom English labels per point may be manually entered selected from an internal library file Three Form C relay outputs two programmable 99 software zones Continuous fire protection during online programming at the panel Program Check automatically catches common errors not to any zone or input point OFFLINE PROGRAMMING Create the entire program in office using a Windows software package programming kit PS Tools separately Upload system programming MS Rev 2 in less than one minute USB programming with standard Male A to Male B cable interface INDICATORS AC Power green Fire Alarm red Supervisory yellow Alarm Silenced yellow System Trouble yellow 2 of 6 DF 60415 C cid 129 12 17 2009 Maintenance Presignal yellow Disabled yellow Battery Fault yellow Ground Fault yellow CONTROLS Acknowledge Step Alarm Silence Drill System Reset lamp test 16 key alpha numeric pad similar to telephone keypad 4 cursor keys Enter Line Information Rev 2 198 point addressable Fire Alarm Con Panel one SLC loop Includes 80 character LCD display printed circuit board mounted on chassis and cabinet VAC operation Rev 2 Same as MS 9200UDLS Rev 2 with 240 VAC operation Reverse Polarity Transmitter Module Provides output for local energy municipal box transmitter and trouble Contains PS Tools Programming software for Win PC computer cable not included Optional dress panel for MS 9200UDLS Rev 2 Trim Ring for semi flush mounting Battery backbox holds up to two 25 AH batteries and Battery box houses two 55 AH batteries Battery charger for lead acid batteries with a rating 25 to 75 AH Remote battery charging system for lead acid bat with a rating of 55 to 120 AH Requires additional BB for mounting Series Batteries see data sheet DF 52397 Optional transformer Increases system power to 6.0 amps Use XRM 24BE with MS 9200UDLS Rev Cable printer personal computer interface required for printer or for local upload download pro UL listed compatible event printer Uses tractor fed Monitoring Module in bottom of enclosure with optional mounting kit PN Connects to primary and secondary DACT tele output ports for internet communications over customer ethern