Fire-Lite MS-9600 (C E) Addressable Fire Alarm Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

www firelite com Fire MS 9600 is a compact cost effective intelli addressable fire alarm control panel with a capacity of addressable Fire cid 127 Lite devices on two loops 2nd loop A single Signaling Line Circuit SLC loop sup up to 159 smoke detectors and 159 control or monitor The panel uses surface mount technology and is for ease of installation and programming It fea the latest in advanced fire protection technology in maintenance alert and automatic detector test Loop SLC can be configured for NFPA Style 4 6 or 7 operation Optional module for adding a second SLC loop Part SLC supports up to 318 addressable devices 159 detec and 159 monitor control or relay modules including new addressable heat detector duct detector and dual module SLC loop maximum length 10,000 ft 3,048 m 12 AWG mm2 Needs twisted shielded wire 3,000 ft unshielded wire Appliance Circuits NAC Two onboard NAC with additional NAC capability using control modules CMF 300 Silence Inhibit and Auto Silence timer options Continuous March Time Temporal or California code for circuit board NAC with two stage capability Selectable strobe synchronization per NAC 6.0 amps total NAC power 7.2 amps total system power and Software Auto program learn mode reduces installation time Fully programmable from local keypad local PS 2 key or PC via PK 9600UD Windows utility Two level user programmable passwords Custom English labels per point may be manually entered selected from an internal library file Two programmable Form C relay outputs 99 software zones Interface Remote Acknowledge Silence Reset and Drill via addres monitor modules ACS series annunciators or LCD Remote annunciator EIA 232 printer PC interface variable baud rate on main board 7 2001 A1 200 cid 27 cid 17 cid 19 cid 20 Addressable S624 Integral 80 character LCD display with backlighting Real time clock calendar with automatic daylight savings control History file with 1,000 event capacity EIA 485 supporting up to 32 ACS series annunciators EIA 485 supporting up to 32 LCD 80F annunciators Fire Technology Sensitivity testing with printable results Automatic drift compensation Maintenance alert warns when smoke detector dust accu is excessive Automatic device type code verification One person audible or silent walk test with walk test log printout Point trouble identification document is not intended to be used for installation purposes We try to our product information up to date and accurate We cannot cover all spe applications or anticipate all requirements All specifications are subject to without notice For more information contact Fire cid 127 Lite Alarms One Fire Place Northford Connecticut 06472 Phone 800 627 3473 Toll Free 877 699 4105 FAX Back 888 388 3299 in the U S A Page 1 of 4 cid 2 cid 4 cid 16 cid 2 cid 4 cid 5 cid 6 cid 10 cid 23 cid 5 cid 3 cid 23 cid 16 cid 4 cid 16 cid 3 cid 1 VDC E ALA RM ANN UNCIATOR Power Silenced tep ce o ld 2 sec IA 485 Interface built the m otherboard w ires VDC IA 485 in A C S ode 2 w ires N N U N C IATO R S F M LE D C S A C M M VDC O ptional F orm C 5 A m p R elays A C s N otification ppliance C ircuits ells signals strobes D A C T F IA 232 Interface built the m otherboard ptional R everse P olarity C ity B ox utput p n 4X T M F M O K E D E T E C TO R S D 350 D 350T P 350 E AT D E T E C TO R 350 U C T D E T E C TO R S 350P 350R P O N ITO R S M F 300 M F 302 M F 300 R F 300 IN I M O N ITO R M F 301 SLC requires use of a specific wire type to ensure proper circuit operation It is recom that all SLC wiring be twisted pair shielded to minimize the effects of electrical Wire size should be no smaller than 18 AWG 0.75 mm2 and no larger than 12 3.25 mm2 wire wire size depends on the length of the SLC circuit Use the table below to determine the wiring requirements for the SLC Requirements shielded in Feet meters 3,048 2,438 1,486 983 unshielded 915 Wire Type1 AWG Belden 9583 Genesis 4410 98230 WPW D999 AWG Belden 9581 Genesis 4408 98430 WPW D995 AWG Belden 9575 Genesis 4406 4606 Signal 98630 WPW D991 AWG Belden 9574 Genesis 4402 4602 Signal 98300 WPW D975 18 AWG U LL S TATIO N G 12 LX AWG wire size conversion to metric size 12 AWG 3.25mm2 14 AWG 2.00mm2 16 AWG 1.30mm2 18 AWG 0.75mm2 2 of 4 DF 52103 Local Piezo sounder Waterflow nonsilenceable selection per monitor point System alarm verification selection per detector point PAS Positive Alarm Sequence and presignal delay per NFPA 72 compliant Optional 4XTMF module conventional reverse polarity city transmitter INDICATORS POWER green ALARM red yellow Silenced yellow TROUBLE yellow yellow yellow FAULT yellow FAULT yellow SWITCH CONTROLS SILENCE RESET lamp test pad with full alphabet cursor keys 16 20 cid 5 cid 8 cid 16 feature a polling LED and rotary switches for ad low profile ionization smoke low profile photoelectric smoke Addressable low profile photoelectric smoke with thermal sensor response low profile heat detector R with of Rise option Photoelectric duct smoke detector R with relay Addressable Monitor Module for one zone of dry contact initiating devices in standard 4 10.16 cm box Includes cover plate and end of line resistor may be configured for either a Style B B or Style D Class A IDC Dual Monitor Module Same as MMF 300 except provides two Style B Class B only IDC Miniature version of MMF 300 Excludes LED Style D option Connects with wire pigtails mount in device backbox Similar to MMF 300 but may monitor up to 20 two wire detectors Requires 24 VDC power Consult factory for smoke detectors Control Module for one Style Y Z B A zone of supervised polarized Appliances Mounts directly to a 4 cm electrical box Notification Appliance option requires external 24 VDC to power appliances relay module containing two isolated of Form C contacts which operate as a switch Mounts directly to a 4 10.16 cm surface mount using the SMB500 manual pull station with interface mounted inside module isolates the SLC loop from short conditions required for Style 7 operation to mount all modules except the MMF 301 M301 with legacy Fire cid 127 Lite 300 Series devices consult factory for further information on all 300 series devices

Related Files