Fire-Lite MS4412B MS4424B(E) Fire Alarm Control Panels

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-ms4412b-ms4424b-e-fire-alarm-control-panels-4013256789.pdf
Type PDF
Size 678.53 KB
Downloads

Text Preview

July 12 2004 A2 200 cid 26 cid 17 cid 5 cid 28 cid 29 cid 17 cid 20 cid 24 cid 25 cid 24 cid 28 cid 17 cid 29 cid 25 cid 26 cid 28 cid 30 Conventional Fire MicroScan 4412B and 4424B are 12 volt and 24 volt Class B Fire Alarm Control Panels Compact cost effective the 4XB Series panels are powerful a variety of options designed to meet almost any application including Local Auxiliary Remote and Proprietary Fire Alarm Systems Device Circuits IDC Four Style B Class B Zones 1 2 General Alarm Operation Zone 3 General Alarm or Waterflow Operation Zone 4 General Alarm or Supervisory Operation Disable Enable control per IDC End of Line Resistor 2.2K 1 2 watt R 2.2K UL listed 4.7K 1 2 watt 71252 UL listed Maximum loop resistance MS 4412B ohms ohms Appliance Circuits NAC Two Style Y Class B 1.5 amps each Disable Enable control per NAC Alarm and trouble resound Programmable Silence Inhibit capability End of Line Resistor 2.2K 1 2 watt R 2.2K UL listed 4.7K 1 2 watt 71252 UL listed Maximum allowable voltage drop due to wiring 2 VDC 2.25 amps of notification appliance power Outputs Resettable four wire smoke detector power 200 mA Non resettable power 200 mA subtract from four wire power Use of above auxiliary power outputs does not de rate 2.25 amps of NAC power Form C alarm and trouble relays and Software Programmable Alarm Verification with discrimination smoke detectors and contact devices Last Event Recall feature traps unverified alarms or troubles One man Walk Test feature with zone change indication zone trouble indication and Batteries Fuseless power limited technology meets UL power requirements effective May 1 1995 on all cir excludes optional municipal box output Alarms is a Honeywell company document is not intended to be used for installation purposes We try to keep product information up to date and accurate We cannot cover all specific or anticipate all requirements All specifications are subject to without notice more information contact Fire cid 127 Lite Alarms One Fire Lite Place Northford 06472 Phone 800 627 3473 Toll Free FAX 877 699 4105 battery charger capable of charging up to 15.0 batteries batteries larger than 7.0 AH require use of battery box Battery earth fault supervision System Features Meets the requirements of NFPA 72 Local Auxiliary Station and Proprietary Fire Alarm Systems Extensive transient protection Electronics and operational controls fully enclosed in cabinet capable of housing up to 7.0 AH batter DP 4424B dead front dress panel option included with Canadian product Optional TR 2 R trim ring for semi flush mounting be 16 40.64 cm center studs Slide in labels for zone identification 07 12 04 Page 1 of 2 Relay by zone capability with optional 4412ZM 12 V or 24 V modules Local energy or remote station connection with optional 12 V or 4XTMF 24 V modules Optional RZA 4XF remote annunciator mounts to single box and requires 4412LM 12 V or 4XLMF 24 V driver modules cid 5 cid 3 cid 17 cid 3 cid 20 cid 5 cid 8 cid 4 cid 10 Switch Controls POWER Control panel alarm and trouble relay contact ratings amps 30 VDC resistive amps 30 VAC resistive 14.218 36.113 cm high x 14.718 37.383 cm x 0.675 1.714 cm deep 14.0 35.56 cm high x 14.5 36.83 wide x 7.62 cm deep Same as above with ULC listing and Class B 12 VDC FACP Class B 24 VDC FACP ALARM TROUBLE TROUBLE SILENCED TROUBLE Indicators Silence to silence tone Silence to silence alarm Activate to sound alarm for control and detectors Primary input power MS 4412B MS 4424B C 120 60 Hz 1.2 A MS 4424BE 230 VAC 50 Hz 0.6 A Wire size minimum 14 AWG 2.00 mm with 600 V Total 24 V system power 2.45 amps Standard notification appliance circuits 2 Style Y Notification appliance power 2.25 amps Maximum current per NAC 1.5 amps Resettable four wire smoke detector power 200 subtract from total 24 V system power Non resettable power 200 mA subtract from four smoke power Battery charger range 7 AH 15 AH BB 17F battery for 12 AH batteries Charger float rate 13.8 V 1.5 amps 27.6 V 1.5 amps Relay Interface dead front panel as MS 4424B with 230 VAC 50 Hz UL listed zone annunciator requires or 4XLMF annunciator driver for RZA 4XF for annunciator driver for RZA 4XF for station output or municipal box for 4412B station output or municipal box for 4424B module four relays by zone alarm contacts for 4412B module four relays by zone alarm contacts for 4424B Disconnect Switch provides zone disconnect Polarity Kit required for City of applications internal Dead front Panel in with suffix models Ring semi flush mounting Box required to mount PS 12120 AH 12 V gell cell battery AH 12 V gell cell battery requires use Fire cid 127 Lite BB 17F battery box 4x Walk Test feature with zone indication and zone trouble indica Replacement board for MS 4412B US board for MS 4412BC board for US and Canadian MS 4424B and MS 4424BC 2 of 2 DF 51195 cid 127 07 12 04

Related Files