Fire-Lite MS4424 Fire Alarm Control Panel
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-ms4424-fire-alarm-control-panel-4102637985.pdf |
---|---|
Type | |
Size | 681.71 KB |
Downloads |
Text Preview
July 12 2004 A2 300 cid 14 cid 15 cid 29 cid 28 cid 16 cid 17 cid 26 cid 29 Conventional Fire MicroScan 4424 is a 24 volt four zone Class A Fire Control Panel Compact and cost effective the 4XA panels are powerful offering a variety of options to meet almost any low end application includ NFPA 72 1993 Edition Local Auxiliary Remote and Proprietary Fire Alarm Systems Device Circuits IDC Four Style D Class A Zones 1 2 General Alarm Operation Zone 3 General Alarm or Waterflow Operation Zone 4 General Alarm or Supervisory Operation Disable Enable control per IDC End of Line Resistor 4.7K 1 2 watt 71252 UL listed Maximum loop resistance MS 4424 Appliance Circuits NAC Two Style Y Z Class B A 1.5 amps each Two Style Y Class B only Disable Enable control per NAC Alarm and trouble resound Programmable Silence Inhibit capability End of Line Resistor 4.7K 1 2 watt 71252 UL listed ohms Maximum allowable voltage drop due to wiring 2 VDC 2.25 amps of notification appliance power Outputs Resettable four wire smoke detector power 200 mA Non resettable power 200 mA subtract from four wire power Use of above auxiliary power outputs does not de rate 2.25 amps of NAC power Form C alarm and trouble relays and Software Programmable Alarm Verification with discrimination smoke detectors and contact devices Last Event Recall feature traps unverified alarms or troubles Programmable ring by zone option One man Walk Test feature with zone change indication zone trouble indication and Batteries Fuseless power limited technology meets UL power requirements effective May 1 1995 on all cir excludes optional municipal box output battery charger capable of charging up to 15.0 AH Battery earth fault supervision System Features Meets the requirements of NFPA 72 1993 Edition Auxiliary Remote Station and Proprietary Fire Systems Extensive transient protection Alarms is a Honeywell company document is not intended to be used for installation purposes We try to keep product information up to date and accurate We cannot cover all specific or anticipate all requirements All specifications are subject to without notice more information contact Fire cid 127 Lite Alarms One Fire Lite Place Northford 06472 Phone 800 627 3473 Toll Free FAX 877 699 4105 07 12 04 Page 1 of 2 Electronics and operational controls fully enclosed in cabinet capable of housing up to 12.0 AH DP 4XF dead front dress panel option included with Canadian product Standard notification appliance circuits 2 Style Y Z 2 Y only Notification appliance power 2.25 amps Maximum current per NAC 1.5 amps Resettable four wire smoke detector power 200 subtract from total 24 V system power Optional TR 4XRF trim ring for semi flush mounting Non resettable power 200 mA subtract from four 16 40.64 cm center studs smoke power Slide in labels for zone identification Relay by zone capability with optional 4XZMF module Local energy or remote station connection with optional module Optional RZA 4XF remote annunciator mounts to single box and requires 4XLMF LED driver module Volt amp meter capability with optional 4XMMF module 220 240 VAC 50 60 Hz international option cid 5 cid 3 cid 28 cid 3 cid 22 cid 5 cid 9 cid 4 cid 7 Switch Controls POWER ALARM TROUBLE TROUBLE SILENCED TROUBLE Indicators Silence to silence tone Silence to silence alarm Activate to sound alarm for control and detectors Primary input power 120 VAC 60 Hz 1.2 amps 220 VAC 50 60 Hz 0.6 amps suffix Wire size minimum 14 AWG with 600 V insulation Total 24 V system power 2.45 amps Relay Interface Battery charger range 7 AH 15 AH Charger float rate 27.6 V 1.5 amps Control panel alarm and trouble relay contact amps 30 VDC resistive amps 30 VAC resistive 16.125 409.575 mm high x 14.625 371.475 mm x 0.675 17.145 mm deep 16.0 406.40 mm high x 14.5 368.30 mm x 4.75 120.65 mm deep Class A 24 VDC FACP as above with ULC listing and DP dead front panel as MS 4424 with 220 240 VAC 50 Hz transformer UL listed zone annunciator requires annunciator driver for RZA 4XF station output or municipal box module 4 relays by zone alarm contacts meter module Disconnect Switch provides me zone disconnect Polarity Kit required for City of applications internal dead front panel in with suffix model Ring semi flush mounting AH 12 V gell cell battery AH 12 V gell cell battery board 2 of 2 DF 51069 cid 127 07 12 04