2 Single ended Reflective Beam Smoke Detector OSI RI FL intelligent addressable reflector type linear optical smoke detector is uniquely suited for protecting large open with high ceilings where spot type smoke detectors are diffi to install and maintain Ideal applications are warehouses atri aircraft hangers sporting arenas and concert halls The operates primarily on the principle of light obscuration using The OSI RI FL detector is a combined transmitter that can be directly connected to an intelligent detector cir in LiteSpeed or CLIP mode AND EASY ALIGNMENT the imager to the reflector is extremely intuitive fast and Both the infrared transmitter and the CMOS imager are in a movable an adjustable lens assembly can move 20 in the vertical direction and 50 in the hori direction LED directional arrows indicate the direction to move the lens the user to find the imager perfect alignment with the the optimum alignment is found indicated by all green the lens is locked with a slide lever A paintable cover is placed over the front to secure the lever in locked position TO BUILDING MOVEMENT infrared transmitter and receiver imager generates a beam of towards a high efficiency reflector The reflector returns the to the receiver where the received signal is analyzed The in the strength of the received signal when smoke enters area between the unit and the reflector is used to determine alarm condition The receiver imager has a wide 12 field of that automatically tracks the reflector in case of building or support structure movement This allows the OSI RI to be highly resistant to movement eliminating the number one of false alarms and or faults with traditional beam detectors TO SUNLIGHT filtering high speed image acquisition and intelligent soft algorithms provide the OSI RI FL system with higher levels of and greater resistance to high level lighting variability This better resistance to sunlight in its field of view helping to false alarms when saturated by sunlight reflected sunlight any other very bright light sources TO FOREIGN OBJECT INTRUSION smoke imaging techniques allow the detector to avoid alarms from partial and sudden blockage from foreign object AUTOMATIC SENSITIVITY SETTING in the market the sensitivity of the detector is selected and automatically at the optimum sensitivity based on the size of reflector measured in the field of view Devices OSI RI FL single ended beam smoke detector is easy to install adjust Only the head unit needs to be wired and the be aimed without adjusting the detector mounting COMPENSATION detector incorporates automatic drift compensation whereby detector will adjust its detection thresholds in line with any signal reduction of the beam caused by dust or other of the optical surfaces WITH BUILT IN IMAGER HEATER imager ships standard with an internal heating option to pre condensation on the optical surface External power supply Combined transmitter receiver unit Wide 12 field of view Fast easy and intuitive beam alignment indicated by directional arrows Long range coverage of 16 328 ft 5 100 m is standard no sepa long range kit required Highly resistant to building movement tolerates 1 movement Resistant to strong light sources does not alarm when saturated Resistant to solid object intrusion Automatic sensitivity threshold level settings and drift compensa sunlight 50 horizontal and 20 vertical beam adjustment Built in imager heater Remote test station capable for electronic simulated smoke test ground level Status LED indicators visible from the front and bottom Paintable housing cover Removable plug in terminal blocks Optional heater kit available for the reflector 3 23 2020 Page 1 of 2 SPECIFICATIONS SPECIFICATIONS Dimensions Detector Height 6 152.4 mm Width 10 254 Depth 4.5 114.3 mm Dimensions Reflector Height 9.06 230 mm Width 7.87 SPECIFICATIONS Protection Range 16 ft to 328 ft 5 m to 100 m Adjustment Angle 20 degrees vertical 50 degrees horizontal Sensitivity Levels Level 1 25 Level 2 30 Level 3 40 mm Weight Installed 2.48 lbs 1.12 kg Weight Shipping 3.91 lbs 1.77 kg Wire Gauge for Terminals 14 AWG 2.08 mm SPECIFICATIONS OSI RI FL Operating Voltage Range Nominal 24 VDC Minimum 15 VDC Maximum 32.0 VDC Maximum Standby Current Maximum Alarm Current LED on mA 32 VDC mA 24 VDC mA 15 VDC mA 32 VDC mA 24 VDC mA 15 VDC ES 50X 100ma normal operating 200 ma short circuit ES 200X 100ma normal operating 400 ma short circuit MS 9600LS 100ma normal operating 400 ma short circuit SPECIFICATIONS BEAMHKR Voltage Range 15 to 32 V Maximum Current 450 mA Max at 32 V Power Consumption W 24 V W 32 V SPECIFICATIONS RTS151KEY A Voltage Range 10.2 to 32 VDC Current Range 9 mA Min to 11 mA Max SPECIFICATIONS Operating Temperature UL Listed for use from 32 to 100 Application Temperature Range 4 to 131 20 to to 37.8 Humidity Range 0 to 95 relative humidity non condensing 4 50 and switch Test Reset Features Local alarm test switch local alarm reset Remote with and RTS151KEY A test stations OSID R test filter Smoke Detector Spacing On smooth ceilings 30 60 feet projected beams and not more than one half that spac between a projected beam and a sidewall Other spacing may used depending on the ceiling height airflow characteristics response requirements See NFPA 72 S524 in Canadian Listings UL ULC S911 FM PR449231 CSFM 7260 0075 0506 Line Information OSI RI FL Intelligent imaging beam smoke detector including UL ULC listed OSP 002 Laser alignment tool OSP 004 Test filter 10 pack RTS151 Remote test station UL listed RTS151KEY Test and reset station with key lock flush mount RTS151KEY A Test and reset station with key lock flush mount listed listed BEAMHKR Heater kit for the reflector 6500 MMK Multi mount accessory for ceiling or wall mounting additional mounting adjustment is a trademark of and Fire cid 129 Lite Alarms is a registered trademark of International Inc by Honeywell International Inc All rights reserved Unauthorized use of this is strictly prohibited 2 of 2 DF 60143 C cid 129 3 23 2020 document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Fire cid 129 Lite Alarms Phone 800 627 3473 FAX 877 699 4105 of Origin Mexico

Related Files