Fire-Lite Product Brochure

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-product-brochure-1659830472.pdf
Type PDF
Size 4.85 MB
Downloads

Text Preview

Fire Solutions That Endures Alarms has a legacy simple reliable life safety By designing advanced that also easy to use makes protecting what most easy year after In a world where anything can in an instant you can count the consistency of Fire Lite Innovation that Endures of Contents 3 Addressable Fire Alarm Control Panels 4 Emergency Command Center 6 Conventional Fire Alarm Control Panels 7 Releasing Control Panels 8 Sychronized Power Supplies Pull Stations and Annunciators 9 Addressable Smoke Detection Wireless Technology and Communicators 10 Complete Fire Alarm System 11 Quick Reference Guide Fire Alarm Control Panels Alarm innovative addressable control panels offer a wide range capabilities to provide superior value and flexibility They are easy to install program with notification appliance circuit NAC synchronization enable emergency personnel to quickly locate a fire The built in protocol ensures the fastest possible device response to help reduce property damage and save lives Series and ES 200X Single SLC that provides support for 50 ES 50X or 198 ES 200X addressable devices Upload download panel programming database and flash firmware with USB thumb drive Support for addressable multi criteria fire and CO detector 4 programmable function keys to save time Built in Class A capability for all 4 NACs no optional card required Trouble indication for SLC devices not programmed Integrated SWIFT display driver and annunciator built in to panel Notification appliance circuits have built in sync for the industry and Gentex manufacturers including System Sensor Wheelock of 318 devices per SLC with SLC 2LS option card MS 9600UDLS Up to 159 detectors and 159 control monitor modules LiteSpeed protocol for SLC communication polls 10 devices at a time and operates on standard unshielded wire Auto programmable function reduces installation time Advanced fire technology sensitivity testing and automatic drift compensation 4 programmable Class B and 2 Class A NACs Command Center ECC Alarm Emergency Command Center ECC leverages advanced technology and 60 years of life safety to deliver critical messages through non proprietary systems The ECC is ideal for any building that needs flexible multi zoned and highly configurable fire evacuation and mass notification system that easy to maintain Primary Console Seamless integration and control when connected to select Fire Lite addressable panels through the ANN ACS communication bus May be used with any UL listed control panel messages can be initiated by using a dry contact or via a fire alarm NAC circuit Includes a single 25 volt 50 watt speaker circuit upgradable 100 watts and 2 speaker circuits with optional amplifier Speaker circuits are expandable by up to 8 outputs with an optional ECC CE6 module Can support up to 14 prerecorded messages that are field programmable for up to 60 seconds of message playback can be used to activate Built in 2 Amp NAC output with sync generator 8 Command Input Circuits messages 1 to 8 Optional amplifier can be configured as a backup in the event the primary amplifier fails Amplifiers are independently powered to eliminate system condition Optional transformer conversion module available for 70.7 volt speaker operation Supports charging up to 26AH batteries during a short circuit handsets quick installation Fighter Telephone Provides supervision annunciation and control for up to 24 remote Built in auto program feature Can be wired for class A Style 6 or Style 7 or class B Style 4 configuration Can be configured for Multi Phone Jack Audio Circuit supervision Allows simultaneous operation of up to 10 firefighter remote handsets the ECC 50 100 Operator Console Provides complete control and has an interface similar Includes built in microphone message and zone control A maximum of 8 ECC LOCs display consoles ALL CALL paging along with combination of other remote Page Unit Includes built in microphone ALL CALL paging along with message control A maximum of 8 ECC RPUs display consoles Additional 9th button can be used activate an optional monitor module that can be mounted such as HVAC shutdown the cabinet for applications combination of other remote Remote Microphone Includes built in microphone for ALL CALL paging over available speaker zones A maximum of 8 ECC RMs combination of other remote display consoles Remote Telephone Module Module allows authorized personnel access Remote users have the ability to initiate prerecorded messages or make live announcements the system via any telephone the ECC 50 100 ECC 50BDA ECC 125DA Audio Externally mounted amplifiers provide an additional 50 or 125 watts of addressable audio power when connected Up to 8 distributed amplifiers can be connected to the ECC 50 100 for a total of 1100 watts of audio power Includes 4 built in speaker circuits which are expandable ECC CE4 module a maximum of 24 audio circuits Speaker output voltage is field configurable on ECC 50DA for either 25 volts or 70.7 volts of operation Includes a built in power supply and backup battery charger ECC 50BDA provides 50 watts of power with 50 watts as backup power 100 watts primary and 50 watts of backup power requires ECC 50WBU can also provide 100 watts of 8 circuits with an optional Fire Control Panels 24 volt conventional fire alarm control panels FACPs bring the latest in microprocessor technology conventional fire controls With 2 zone 4 zone 5 zone and 10 zone configurations these units offer to meet most local state and national requirements in the most efficient and effective way possible 2 initiating zones that are com patible with 2 and 4 wire smoke detectors 1 zone programmable and waterflow combo supervisory 1 Notification Appliance Circuit with built in horn strobe synchronization 3.0 amps maximum alarm current 4 initiating zones that are compatible with 2 and 4 wire smoke detectors 1 zone programmable for combo supervisory and waterflow 2 Notification Appliance Circuits synchronization with built in horn strobe Optional module converts all 4 initi ating zones and 2 NACs to Class A 3.0 amps maximum alarm current expandable to 6.0 amps with optional second transformer 5 zone Style B Class B or 5 zone Style D Class A with optional module 3.0 amps maximum alarm current 10 zone Style B Class B or 10 zone Style D Class A with 2 optional modules 7.0 amps maximum alarm current Shared Features and Specifications 4 NAC Circuits Style Y Class B or 4 NAC Circuits Style Z Class A with optional modules Built in horn strobe NAC synchronization with Remote Synchronization Output Integral 80 character LCD display with backlighting and keypad Annunciator bus supports up to 8 devices including ANN 80 LCD Remote Annunciator ANN S PG remote serial or parallel printer gateway ANN RLY 10 form C relay board ANN LED Zone annunciator and ANN I O LED driver board for graphic annunciators Built in 2 line digital communicator for off premises monitoring 3 Form C programmable relays Conventional Fire Control Panels Support System Sensor Wheelock Gentex Faraday and Amseco devices Control Panels to meet the most demanding conventional releasing applications the flexibility and reliab

Related Files