Fire-Lite Sensiscan 2000 Fire Alarm Control Panel

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-sensiscan-2000-fire-alarm-control-panel-0734182956.pdf
Type PDF
Size 1.09 MB
Downloads

Text Preview

October 2 2002 A2 500 2000 Alarm Control Panel Conventional E A Fire Fire Sensiscan 2000 fire alarm control panel is multi zone unit designed for maximum flexibility and ease installation The microprocessor control and modular enable users to configure the system to meet precise requirements Field programmability simpli initial installation and allows quick updates to meet needs center of the system is the Central Processor Unit module which monitors and controls up to 7 modules Modules are user selected and may be in various combinations to provide up to 56 input circuits communications are accomplished over a high serial data bus Each module on the bus is auto addressed supervised and controlled by the Device Circuits IDC Large conventional system capacity up to 56 Style B or IDCs may be expanded in increments of 4 or 8 utilizing D Class B or A or IZ 8F modules Initiating zones may be programmed to function as re ACKNOWLEDGE SILENCE or RESET inputs Alarm and trouble reminder option ALARM red and TROUBLE yellow LEDs indicate sta of each initiating device circuit Appliance Circuits NAC Dual Style Y or Style Z Class B or A NACs may be expanded in increments of 4 or 8 utilizing modules or a combination of IC 4F and ICE 4F ON green and TROUBLE yellow LEDs indicate sta of notification and control circuits March Time or Temporal Code selectable per output Silence inhibit timer option with selectable times AUTO SILENCE option alarm cutout with selectable Non Alarm Point selection for lower priority monitor and of non fire signals Resound of subsequent alarms troubles or supervisory each with a distinct local audible indication Auxiliary power supplies available to provide additional for notification appliances EIA 485 serial port for high speed data communication remote annunciators May be used for remote AC 2000 SIGNAL SILENCE and SYSTEM RE NACs may be selected for California Code option com with Code Sections 32002 and 32003 and Software Field programmable with separate access for initial sys programming and system program changes Multiple passwords and a special programming key en the integrity of the field program information Each initiating zone may be programmed for Normal or Supervisory operations One man Walk Test feature with zone change audible and zone trouble indication Programmable Alarm Verification with discrimination smoke detectors and contact devices Nonvolatile memory retains program information even total loss of power Automatic memory checks verify Map any output circuit to any input circuit in nonvolatile memory Enable Disable of circuits from the front panel switches document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applica or anticipate all requirements All specifications are subject to change without For more information contact Fire Alarms One Fire Lite Place Northford 06472 Phone 800 627 3473 FAX 877 699 4105 in the U S A Page 1 of 4 System Features Extensive transient protection Releasing Service capability with selectable time de abort circuit and manual release Multiple hazard releasing capability Four 4 cross zone Two stage Alert Evacuation option meets Canadian and per module requirements Pre signal capability with selectable time delays and Alarm Sequence PAS per NFPA 72 Standards Field programmable supervisory complies with NFPA requiring distinction between supervisory con and open circuit trouble conditions All initiating and notification circuits are power limited to the latest UL requirements Labels may be easily inserted to provide identification Door may be field mounted with hinge on right or left all circuits side APPROVALS Sensiscan 2000 complies with the following standards NFPA 72 1993 National Fire Alarm Code Auxiliary Remote Station and Proprietary Fire Systems and Central Station Signaling Systems LINE INFORMATION Base Equipment for Sensiscan Includes CPU 2000 CHS 4F Chassis programming key labels VP 1F dress basic cables manual and miscellane hardware CPU 2000 includes two Notification Ap Circuits system alarm and trouble re remote station and master box transmit The CPU communicates with up to 7 any mix of IZ IC CR and TC one IZ is required Initiating Zone module provides eight Style B Class B initiating device circuits Plug in terminal blocks are included ease of installation and service Same as IZ 8F with four 4 yellow supervi Initiating Device Circuits zones points 5 8 Re for Canadian Supervisory Service Same as IZ 8F with eight 8 yellow supervi Initiating Device Circuits zones points 1 8 Re for Canadian Supervisory Service Initiating Zone Expander converts to eight 8 Style D Class A initiating circuits maximum of one per IZ 8F terminal blocks are included for ease installation and service Initiating Zone module Provides 4 Style B Class B initiating device NOTE Will not accept an IZE AF 2 of 4 DF 50439 Indicating Notification Appliance Module Provides four 4 Style Y or Z Class B or A notification appliance Maximum signaling current is 3.0 per NAC or 6.0 amps per module sub to power supply limitations includes bell power harness and ELRs terminal blocks Indicating Notification Appliance Expander expands IC 4F to provide a of eight 8 Style Y or Style Z NACs Cir ratings are same as IC 4F maximum of per IC 4F Plug in terminal blocks Control Relay module four 4 relay contacts rated at 5.0 A 120 or 28 VDC resistive per circuit Plug terminal blocks are included for ease of and service Control Relay Expander expands to provide a total of eight 8 Form C contacts maximum of one per CR 4F also be connected to add four 4 relays IC 4F TC 2F or TC 4F Plug in terminal Time Control module used for release and pre signal alert applications Release mode in cross zone abort circuit two sole circuits warning bell circuit with triple option and countdown time display option includes programmable Plug in terminal blocks Time Control module used for mul releasing service or two stage Release mode provides independent release circuits each with cross zone delay timer and timer Plug in terminal blocks Supplies the regu power needed to run the 2000 modules It also up to 2.0 amps of RMS notification appliance Up to 200 mA of reset power is available for four smoke detectors and annun The MPS 24BF is power and contains an integral battery charger capable of 7 to 17 amp hour lead acid batteries The is recommended only for CAB A3F single row Supplies the regulated power needed to run full size Sensiscan 2000 It supplies up to 3 amps of notification appliance power permitting the use a variety of standard UL listed 24 VDC notification ap High efficiency switched regulation technology used Up to one amp of re power is available for smoke detectors power limited to the latest requirements Includes in charger for 9.5 to 60 AH batteries The is recommended for two row systems Main Power Meter kit for MPS 24AF only In battery voltage and charging current meters mount hardware and cable AFM Series Annunciators

Related Files