Fire-Lite SNAP Series Z Series ZRS Strobes, ZNS Horn Strobes

File Preview
File Preview
Click below to download for free

Text Preview

Series Z ZRS Strobes ZNS Horn Cooper Wheelock Series Z notification appliances feature easy snap on base that is designed to simplify the installa and testing of horns strobes and horn strobes The sepa Series Z snap on base can be pre wired so circuit wiring be fully tested before the appliance is installed and before walls are covered Once all surrounding work is complete appliance can be simply installed by snapping it on the Shorting contacts in the base which provide continuity circuit testing are permanently opened when the appliance installed so any subsequent removal of the appliance will a trouble condition on that circuit at the control panel circuit supervision is enabled The same base is used for Series Z horns strobes and horn strobes to provide con installation and easy replacement of appliances if A locking screw is also included for the appliance to extra secure installation Cooper Wheelock Series Z appliances incorporate the dependable circuitry and high efficiency optics that are in Wheelock RSS strobes NS Horn Strobes and NH that have the same high performance ratings The Z appliances are compatible with all UL Listed panels and all panels that are compatibility listed with RSS NS and NH appliances EZ Mount SNAP design with separate base plate provides to pre wire the base and test the circuit wiring before walls are covered The base plate is protected by a disposable cover and the can quickly snap onto the base after the walls painted Patented EZ Mount Universal Mounting Plate ZBASE single plate for ceiling and wall mount installations Wall mount models feature field selectable candela settings 15 30 75 110cd and 135 185cd Ceiling Mount models feature field selectable candela set of 15 30 75 95cd and 115 177cd Strobes can be synchronized using the Wheelock SM or Sync Modules or a power supply with built in Sync 12 and 24 VDC models with UL Voltage using DC or unfiltered VRMS input voltage Strobes produce one 1 flash per second over the Voltage range ZNS ZRS models Selectable Continuous Horn or Temporal Code 3 Tones selectable 90 or 95 dBA setting ZNH ZNS models Selectable 12 or 24 VDC in one appliance ZNH model ADA NFPA UFC ANSI and OSHA 29 Part 1910 165 com G 503 Devices ZNS ZRS ZNS ZNH WARNING PLEASE READ THESE AND ASSOCIATED INSTRUCTIONS CAREFULLY USING SPECIFYING OR APPLYING PRODUCT FAILURE TO COMPLY WITH OF THE FOLLOWING INSTRUCTIONS AND WARNINGS COULD RESULT IMPROPER APPLICATION INSTALLATION OPERATION OF THESE PRODUCTS AN EMERGENCY SITUATION WHICH RESULT IN PROPERTY DAMAGE AND INJURY OR DEATH TO YOU AND OR Notes Strobes are designed to flash at one 1 flash per second over their Voltage Range All candela ratings represent minimum effective strobe based on UL Standard 1971 Series ZNS Strobe products are listed under UL Standards and 464 for indoor use with temperature range of 32 120 0 to 49 and maximum humidity of 93 2 Series ZNH horns are listed under UL Standard 464 for signal appliances indoor use only Voltage Range is the newest terminology used UL to identify the voltage range Prior to this change UL the terminology Voltage Range 2 26 10 Page 1 of 4 1 Series ZNS Rating per UL Standard 1971 2 Series ZNS ZNH Horn dBA Ratings Volume 10ft per 464 dBA 10ft 24VDC 12VDC 24VDC 3 Horn 3 Series ZRS UL Maximum Current 24VDC Wall Mount Ceiling Mount VDC UL maximum current rating is the maximum RMS current within the listed voltage range 16 33V for 24V units For strobes the UL current is usually at the minimum listed voltage 16V for 24V units For audibles the maximum current is usually at the max listed voltage 33V for 24V units For unfiltered FWR ratings see installation instructions 4 Series ZNS UL Maximum Current Mount Strobe Models Mount Strobe Models ZNS ZNH 24VDC 95 dBA 90 dBA VDC ZNS ZNH 12VDC 89 dBA 84 dBA VDC 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd UL maximum current rating is the maximum RMS current within the listed voltage range for 24V units For strobes the UL maximum current is usually at the minimum voltage 16V for 24V units For audibles the maximum current is usually at the listed voltage 16V for 24V units For unfiltered FWR ratings see installation notification appliances shall be listed for indoor and shall meet the requirements of FCC Part 15 Class B appliances shall be listed under UL Standard 1971 Stan for Safety Signaling Devices for Hearing Impaired and UL 464 Fire Protective Signaling The appliances shall a Patented Universal EZ Mount backplate that shall allow to a single gang double gang 4 inch square 4 inch or a 3 octal backbox Two wire appliance wiring be capable of directly connecting to the mounting back Continuity checking of the entire NAC circuit prior to any audible visual notification appliances shall be A dust cover shall fit and protect the mounting plate duct cover shall be easily removed when the appliance is over the backplate Removal of an appliance shall in an alarm condition by the Fire Alarm Control Panel appliances shall produce a minimum flash rate of 60 per minute 1 flash per second over the Regulated Volt Range of 16 to 33 VDC and shall incorporate a Xenon enclosed in a rugged Lexan lens The strobes shall 2 of 4 df 60308 a1 2 26 10 available with 2 or 4 field selectable settings in one unit and be rated per UL 1971 for up to 185cd for wall mounting 177cd for ceiling mounting The strobe shall operate over an temperature range of 32 to 120 0 to 49 and listed for maximum humidity of 95 RH Strobe inputs shall polarized for compatibility with standard reverse polarity of circuit wiring by a Fire Alarm Control Panel and horn strobes shall be listed for indoor use under UL 464 The horns shall be able to produce a continuous or a temporal Code 3 output that can be synchronized horns shall have at least 2 sound level settings of 90 and 95 synchronization of strobes or temporal Code 3 audibles is the appliances shall be compatible with the Wheelock SM and DSM Sync Modules or a power supply with built Sync Protocol The strobes shall not drift out of synchroniza at any time during operation Audibles and strobes shall be to be synchronized on a 2 wire circuit with the capability to the audible if required If the sync module or power sup fails to operate i e contacts remain closed the strobes revert to a non synchronized flashrate Diagrams FACP EOLR APPLIANCE Audible

Related Files