Fire-Lite SpectrAlert® Advance Chime Strobes
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-spectralert-advance-chime-strobes-0649287531.pdf |
---|---|
Type | |
Size | 988.20 KB |
Downloads |
Text Preview
SpectrAlert Advance Output CHR CHW Chimes CHSR CHSW Chime Strobes Sensor SpectrAlert Advance selectable output and chime strobes are private mode notification appli used to alert trained personnel to investigate possible situations and to take appropriate action Security and nurse workstations are ideal locations for chime Advance chimes and chime strobes are rich with guaranteed to cut installation times and maximize The SpectrAlert Advance series of notification appli is designed to simplify your installations with features as plug in designs instant feedback messages to correct installation of individual devices and seven candela settings for chime strobes specifically when installing Advance products first a universal mounting plate to a four inch 10.16 cm four inch octagonal single gang or double gang junc box connect the notification appliance circuit wiring to the terminals on the mounting plate attach the chime or chime strobe to the mounting plate inserting the product tabs in the mounting plate grooves device will rotate into position locking the product pins the mounting plate terminals The device will temporarily in place with a catch until it is secured with a captive screw Advance products allow you to choose 12 or 24 volts At 24 volts 15 15 75 30 75 95 110 or 115 candela by of rear mounted slide switch and front view window Chime tones and volume by way of rotary switch Plug in design Shorting spring on mounting plate for pre installation conti Captive mounting screw Torx screw for tamper resistance Field selectable candela settings 15 15 75 30 75 95 Automatic selection of 12 or 24 volt operation at 15 and 15 Minimal intrusion into the backbox Rotary switch for tone selection Two volume settings Electrically compatible with existing SpectrAlert products Specifications Advance chimes and chime strobes shall mount to standard 4.0 x 4.0 x 1.5 backbox 4.0 octagonal backbox 2.0 x 4.0 x 1.875 backbox or double gang A universal mounting plate shall be used for products The notification appliance circuit wiring universal mounting plate Also Advance products when used with at check 115 candela G 236 Devices CHW CHSR Module accessory shall be powered from a notification appliance circuit output and shall on a nominal 12 or 24 volts When used with the Module 12 volt rated notification appliance circuit shall operate between 9 and 17.5 volts 24 volt rated appliance circuit outputs shall operate between 17 33 volts Indoor SpectrAlert Advance products shall between 32 and 120 from a regulated DC or full unfiltered power supply Chime strobes shall field selectable candela settings of 15 15 75 30 75 95 and 115 COMBINATION chime strobe shall be a System Sensor SpectrAlert Model listed to UL ULC 1638 and UL ULC The chime strobe shall comply with the Americans with Act requirements for visible signaling appliances at 1 Hz over the strobe entire operating voltage The strobe light shall consist of a xenon flash tube and lens reflector system The chime shall have two options and an option to switch between a temporal and a non temporal continuous pattern These are set by a multiple position switch MODULE module shall be a System Sensor Sync to UL ULC 464 and shall be approved for fire protective The module shall synchronize SpectrAlert strobes at 1 and chimes at Temporal 3 Also while operating the the module shall silence the chimes on chime strobe over a single pair of wires The module shall mount to 4.688 x 4.688 x 2.125 backbox The module shall also two Style Y Class B circuits or one Style Z Class A The module shall synchronize multiple zones Daisy two or more synchronization modules together will all the zones they control The module shall not on a coded power supply Specifications Standard operating temperature 32 to 120 Humidity range 10 to 93 non condensing indoor Strobe flash rate 1 flash per second 4 20 10 Page 1 of 4 Nominal voltage regulated 12 VDC FWR or regulated 24 Operating voltage range 8 V to 17.5 V 12 V nominal or V to 33 V 24 V nominal NOTE CHS products will at 12 V nominal only for 15 cd and 15 75 cd terminal wire gauge 12 to 18 AWG Chime strobe dimensions including lens 5.6 H x 4.7 x 2.5 D Chime dimensions 5.6 H x 4.7 W x 1.3 D Listings and Approvals listings and approvals below apply to SpectrAlert Advance Output Chimes and Chime Strobes In some cases modules may not be listed by certain approval agen or listing may be in process Consult factory for latest list status UL ULC Listed file S4011 FM approved MEA approved file 452 05 E CSFM approved file 7125 1653 188 CHSR CHSW file CHR CHW Information Chime red Same as above with ULC listing Chime white Same as above with ULC listing Chime strobe red Same as above with ULC listing Chime strobe white Same as above with ULC listing Backbox skirt wall red Same as above with ULC listing Backbox skirt wall white Same as above with ULC listing Draw UL Maximum mA RMS Pattern dB Out cd cd cd cd cd cd 17.5 Volts 33 Volts 1 Second Chime HIGH 1 Second Chime LOW 1 4 Second Chime HIGH 1 4 Second Chime LOW Temporal Chime HIGH Temporal Chime LOW 5 Second Whoop HIGH 5 Second Whoop LOW One Time Chime 1 Second Chime HIGH 1 Second Chime LOW 1 4 Second Chime HIGH 1 4 Second Chime LOW Temporal Chime HIGH Temporal Chime LOW 5 Second Whoop HIGH 5 Second Whoop LOW One Time Chime cd cd cd 2 of 4 DF 52428 A3 4 20 10 Selection tone selection is accomplished by using the rotary switch on the back the product The current draw and sound measurements for various tones are listed below Patterns Rate Out Chime Chime Chime Chime Chime Chime Whoop Whoop Test Chime Current Draw Maximum mA RMS 17.5 Volts 33 Volts Pattern Chime Chime Chime Chime Chime Chime Whoop Whoop Test Chime mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA