Fire-Lite SpectrAlert® SP2, SP3 Series SP2 1224MC, SP3 1224MC Selectable Output Wall Speaker Strobes

File Preview
File Preview
Click below to download for free

Text Preview

SpectrAlert SP3 Series SP2 1224MC SP3 1224MC Output Wall Speaker Strobes Sensor SpectrAlert Selectable Output Speaker offer enhanced features that include the widest range of options available and the capability to recognize and for either 12 or 24 volt operation along with the fidel sound quality expected from SpectrAlert speaker technology SpectrAlert Selectable Output Speaker Strobes average current draws that are not only lower than conven fixed candela SpectrAlert products but also lower than selectable candela products In addition the broad fre response range and low harmonic distortion provided by speaker technology provides an accurate and intelli broadcast of evacuation messages SpectrAlert Selectable Output Speaker Strobes a variety of installation friendly features such as the ability mount to a 4.0 x 4.0 x 2.125 10.16 x 10.16 x 5.398 cm without the need for an extension ring Also with the strobe the speaker strobe may be either left or to avoid potential obstructions SpectrAlert Selectable Output Speaker Strobes offer broadest range of candela options In addition the 15 cd 15 75 cd options can operate on either 12V or 24V with no required the device recognizes the applied voltage and to the correct setting automatically The speaker either 25.0 or 70.7 and power tap settings 1 4 1 2 1 2 watt are field selectable SpectrAlert Selectable Output Speaker Strobes the same stylish low profile design as the conven SpectrAlert products for a consistent and aesthetically appearance across the entire product line Fidelity sound quality SP2 Enhanced SPL SP3 Operates on either 12 V or 24 V Widest range of candela options 12 V 15 and 15 75 candela options 24 V 15 15 75 30 75 and 110 candela options Easy candela selection 25.0 and 70.7 volt speaker with four field selectable power Field reversible strobe for left or right mounting Synchronizable with MDL Sync Module Optional surface mount backbox skirt available Specifications System Sensor Model listed to UL 1480 and UL 1971 and be for fire protective signaling systems Speaker shall be of operating at 25.0 or 70.7 nominal VRMS and shall a frequency range of 400 4000 Hz Speaker shall have taps that are selected by shunts The strobe shall consist a xenon flash tube with associated lens reflector system and on either 12 V or 24 V The strobe shall also feature candela output providing options for 15 or 15 75 can when operating on 12 V and 15 15 75 30 75 or 110 operating on 24 V The strobe shall comply with the Amer G 241 Devices mounted with BBS SP2R with Disabilities Act requirement for visible signaling appli flashing at 1 Hz over the strobe entire operating voltage Specifications 4.875 x 8.25 x 2.25 12.383 x 20.955 x 5.715 4.0 x 4.0 x 2.125 10.16 x 10.16 x 5.398 cm back operating temperature 32 to 120 0 to 49 operating voltage 12 or 24 VDC and FWR unfiltered voltage range 12 V 8 17.5 V 24 V 16 33 V voltage range with Sync module 12 V 9 V 24 V 17 33 V of published strobe specifications see also draws in Ordering Information below In May 2004 Laboratories changed standard UL 1971 to require operating current measurements are made using RMS root square instead of peak or average values RMS mea more accurately predict the power consumption of a since they take into account the entire current draw pro including surge repetitive surge and peak values The pub RMS current is the maximum operating current of that within its operating voltage range This current maximum or may not occur at the endpoints of the voltage range May 2004 UL also changed the way they list the voltage of a device All 12 V products will be listed between 8 V and all 24 V products will be listed between 16 33 V devices are considered Any product that not operate within these ranges will be listed as a with its operating voltage specified on the device 10 17 06 Page 1 of 2 Listings and Approvals listings and approvals below apply to SpectrAlert Selectable Wall Speaker Strobes In some cases certain modules not be listed by certain approval agencies or listing may be process Consult factory for latest listing status UL Listed file S4048 ULC Listed file CS549 SP2 1224MC A CSFM approved file 7320 1653 133 MEA approved 127 02 E SP2 1224MC A 461 05 E SP3 1224MC voltage 25.0 or 70.7 VRMS nominal terminals 12 to 18 AWG 3.31 to 0.821 mm range 400 4000 Hz NOTE The SP2 and SP3 are UL listed from 400 to 4000 Hz The SP2 Series will a flat dB output from 100 to 15,000 Hz The SP3 will provide a flat dB output from 500 to 13,000 Hz taps 1 4 1 2 1 and 2 watts Patent numbers 6,049,446 6,127,935 output Reverberant dBA 10 ft 3.048 m W W W 1 4 W Strobe Feature the strobe screw and lifting the strobe out of the rib slot allows the strobe to be 180 and remounted to the base resulting a left mounted strobe configuration Information and Current Draw Speaker Strobes SPL SP2 SPL SP3 Models White Models Backbox Skirt BBS SP2R Maximum DC Maximum FWR Current Current mA RMS mA RMS 17.5 V 16 33 V 8 17.5 V 16 33 V is a trademark and Fire Alarms SpectrAlert and Sensor are registered trademarks of Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Fire Alarms Phone 800 627 3473 FAX 877 699 4105 2 of 2 DF 52393 A 10 17 06

Related Files