Fire-Lite SWIFT™ Wireless System Gateway
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-swift-wireless-system-gateway-4027951836.pdf |
---|---|
Type | |
Size | 738.03 KB |
Downloads |
Text Preview
W GATE Wireless Gateway Alarms SWIFT Smart Wireless Integrated Fire Technol Wireless System can be applied in many situations that are for traditional wired devices In cases where areas of a are difficult or impossible to wire visually sensitive or have access SWIFT wireless sensors provide an efficient reli solution wireless devices communicate via a proprietary wireless protocol to communicate with Fire fire alarm systems by of a SWIFT wireless gateway The SWIFT gateway connects the SLC loop of an ES 200X ES 50X MS 9200UDLS or MS panel using LiteSpeed protocol New type IDs for devices are supported for the ES 200X and ES 50X only allow the FACP to display all events such as alarms and trouble as well as unique trouble conditions required for wire devices This capability eliminates the need for a supplemen annunciator for wireless event messages devices in a SWIFT network develop com links with other devices in the mesh so that a message from a remote device to the closest parent device then to successive parent devices until the message reaches Alternate paths are also identified and supervised by the protocol providing approved Class A wireless communica If a device does not have an established communication path adequate signal strength an additional device such as a wire module may be installed in between so that it will act as a SWIFT gateway system supports up to 50 devices 1 SWIFT gate and up to 49 wireless detectors modules pullstations and A V when used with the ES 200X or ES 50X The MS 9200UDLS MS 9600 UD LS can supports a SWIFT gateway and up to 48 modules pullstations A V bases and 1 display driver maximum number of gateways on a system is limited by the of available SLC addresses on the FACP or a maximum of gateways within common wireless range One W DIS D Wireless Driver and ANN 80 W Annunciator are required with each installed in a system using the MS 9200UDLS or MS control panels The W DIS D and ANN 80 W display events that cannot be displayed on the FACP SWIFT system has been designed so that it can be installed only typical hand tools and magnets However the SWIFT PC utility provides many benefits that can enhance the pro of performing a site evaluation Site Survey installing a sys Mesh Configuration or extracting detailed information from the Diagnostics The utility runs on a Windows laptop and a USB radio antenna W USB inserted into a USB slot to com with wireless devices within range of the PC Once have formed a mesh SWIFT Tools can provide current on all devices in the mesh as long as the PC is within of the SWIFT Gateway result is a fire system that combines both wired and wireless and presents all event information at the panel and or net displays when used and a display driver annunciator when Wireless mesh technology 902 928 MHz frequency Cascading wave mesh operation provides a verification of redun communication paths Any wireless device can be added to act as a repeater Each gateway supports up to 50 addresses 1 wireless gateway display driver if required and up to 49 devices E 1000 Wireless Devices Up to 4 wireless networks can be installed with overlapping radio Site Survey feature allows for an evaluation of a site before the coverage Standard wheel for setting the SLC address Wireless devices use 4 CR 123A lithium batteries Battery Life UL listed for 2 years Control Panels ES 50X ES 200X MS 9200UDLS MS 9600 UD LS Tools Tools is a Windows PC based utility that is used for site eval system configuration and diagnostics The SWIFT Tools pro is used with the W USB adapter to communicate with wireless that are not joined in a network or with one or more wireless and all devices that have formed a network with each A graphic representation of the wireless network provides system data in an effective format including communica links signal strength battery voltage and more operation is supported allowing you to perform site evalu and system configuration and installation can be accomplished using SWIFT Tools when necessary Multi colored LEDs on devices provide feedback for interactions At any point only instance of SWIFT Tools can run on a laptop or PC Tools has the following utilities Site Survey Create Mesh Network Diagnostics Tools works in a wireless environment with the W GATE and within a range of approximately 20 feet 10 3 2018 Page 1 of 2 ceiling System Sensor L series notification device ordered W SYNC Wireless sync module Requires 4 CR 123A batteries SMB500 WH Optional surface mount backbox SWIFT Tools Programming and diagnostic utility Free download firelite com For installation on a typically laptop PC run an approved version of Windows See Minimum System for SWIFT Tools Requires the W USB radio dongle for communication with SWIFT Wireless devices W USB Wireless USB radio antenna dongle that plugs into the port of a PC running SWIFT Tools The W USB provides a link with SWIFT Wireless devices that are within 20 feet and have not formed a mesh Alternately the devices have formed a mesh bringing the PC W USB range 20 ft of the gateway for that mesh will allow SWIFT to acquire information on all devices in that mesh including signal strength for all links W BATCART Wireless battery cartridge 10 pack For use with pullstations and A V bases Listings and Approvals listings and approvals below apply to the W GATE In some certain modules may not be listed by certain approval agen or listing may be in process Consult factory for latest listing sta Listed S2424 7300 0075 0232 Fire Dept COA 6185 Approved ID PV3WFSGW and Codes SWIFT Wireless System complies with the following UL Stan and with NFPA 72 Fire Alarm system requirements 864 268 Tools is designed for systems running Microsoft Win SYSTEM REQUIREMENTS System Windows 7 and Windows 8 32 bit and 64 bit Drive 20 GB hard drive space with minimum 1GB free space hard disk Minimum 512MB RAM speed 1GHz minimum 2.4 GHz recommended Pro 512K Cache and Ordering Information W GATE Fire Wireless SWIFT Gateway 1 SWIFT Gate is required for each wireless mesh and supports up to 48 detectors or modules and one display driver if required to the SLC loop of a compatible panel using LiteSpeed Power may be supplied by the SLC circuit or via an 24VDC input Use of the 24VDC input may be more convenient for service as it for powering down a gateway without shutting down an SLC loop W DIS D LCD user interface for use with the W GATE wireless and an ANN 80 W Remote Annunciator Connects to FACP via the ANN BUS Both W DIS D and ANN 80 W are to display trouble and supervisory conditions that are to the W GATE and its devices One W DIS D is required each W GATE in a system using the MS 9200UDLS or MS ANN 80 W White 80 character LCD annunciator used with the to display wireless specific events not display ed on the W SD355 intelligent wireless photo detector Ships with B501W included Requires 4 CR 123A batteries included W H355R intelligent wireless rate of rise 135 heat detector with B501W base included Requires 4 CR 123A batter included W SD355T intelligent wireless photo heat detector Ships with CR 123A batteries Requires base W H355 intelligent wireless fixed temperature 135 heat detec Ships with B501W base included Requires 4 CR 123A bat included W MMF Wireless monitor module Used to monitor devices with contact actuation Includes a special cover with a tamper magnet Recommended for installation in a box ordered separately rather than a metal back for best performance Ships w