Fire-Lite UOXX7 S3705 Control Unit Accessories, System Certified for Canada
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-uoxx7-s3705-control-unit-accessories-system-certified-for-canada-0956781243.pdf |
---|---|
Type | |
Size | 590.69 KB |
Downloads |
Text Preview
UOXX7 S3705 Control Unit Accessories System Certified for Canada Guide OD Home Contact Us ULC Home Unit Accessories System Certified for Canada Unit Accessories System Certified for Canada Bottom General Information for Control Unit Accessories System Certified for Canada SENSOR UNINCORPORATED DIV OF HONEYWELL INTERNATIONAL INC Ohio Ave Charles IL 60174 5467 USA Module Model s CMF 300A FCM 1 FRM 1 FTM 1A JKM FCM 1 JKM FCM 1C modules Model s M500SA FL b M500SA NT b modules 15 32 V dc 6.5 mA max Model s M500SA b M500SA HW b unit accessories Model s ECLIPS zone interfaces rated 1A 15 32 V Model s M502MA FCI Monitor Module Model s FDM 1 M500DMAP Model s DNRW of line relay modules rating 9 40 V dc 9 35 Vrms Model s EOLR 1A modules rating 15 32 Vdc NS 500uA alarm 3 mA and only compatible for connection only on the intelligent circuit of Secutron control unit models MR 2100 2200 Model s M900MA Isolator Module Model s ISO 6A rating DCL Communication 15 32 V dc stand by current 450 uA per circuit 2.7 mA all active current in isolation 17 mA per circuit 102 mA all circuits rating DCL Communication CCT 15 30 Vdc stand by current 150uA maximum protective voltage 4V reset voltage 7V current 13mA this module is only compatible for connection only on the intelligent communication circuit of Secutron control models MR 2100 2200 isolator modules 15 32 dc 450 Ua Model s M500XA alarm equipment dual monitor modules Model s M500DMAPA phone control modules rated 15 32 V dc 5.0 mA max short circuit Model s M500FPA FCI b phone control modules supply voltage 15 32 V dc 7.5 mA maximum indicating circuit is rated as follows 3 A 24 V Model s FTM 1A M500FPA MIX M500FPA modules 24 V dc 24 mA Model s M500DMR1A FCI M500DMR1A FL M500DMR1A HW M500DMR1A NT Relay Module 24 V dc 0.35 mA Model s M900SRM modules rating 15 32 Vdc NS 350uA alarm 3 mA and only compatible for connection only on the intelligent circuit of Secutron control unit models MR 2100 2200 Model s M902MA monitor modules 15 32 V dc 375 mA max Model s M501MA MMF 301A modules Model s EM 1MMIA Communication CCT 15 30 V dc 485 uA standby 745 uA maximum alarm output 5.4 V 2 mA max at short circuit current monitor modules 15 24 V dc 5.2 mA max 15 V dc on alarm Model s M500DMA FCI M500DMA FL and A monitor modules 15 32 V dc 5.1 mA max Model s M502MA NT monitor modules 24 V dc 230 uA Model s M501MA FCI M501MA FL M501MA HW Module Model s FMM 1 FMM 101 FZM 1 HFS MM HFS MMA JSM FMM 1 JSM FMM 101C JSM FMM 1C KM FZM 1C 5 06 54 PM Control Unit Accessories System Certified for Canada Module for connection on the intelligent communication circuit of Model 9500 remote terminal unit by General and Model IRC 3 24 V dc 230 u Model s M500M M500M HW modules Model s EM 1MIA rating Communication CCT 15 30 V dc 485 uA standby 750 uA maximum alarm output 5.4 V 2 mA max at short circuit current M500MA FCI M500MA FL M500MA NT M500MAB FL M501MA NT M501RA NT M501SA NT modules 15 32 V dc 5.1 mA Model s M502MA HW modules 15 32 V dc 5.1 mA max Model s M500MA M502MA MMF 300A MMF 302A modules 15 32 V dc 5.7 mA compatible with Intelligent Communication Circuit Fire Alarm Control Unit by Fire Alarm Inc Model s MDF 300 modules 24 V dc 230 uA Model s M500DMA HW M500MA HW cabinets for house 2 multi modules Model s BB 2 cabinets for house up to 6 multi modules Model s BB 6 module system sensors rating 15 32 V dc 60 mA per circuit Model s EOLR 1A IM 10A FCI IM 10A FL module system sensors rating 15 32 V dc 60 mA per circuit compatible with Intelligent Communication Fire Alarm Control Unit by Mircom Technologies Inc model FX 2000 Model s IM 10A modules rating 15 32 Vdc 3.5 mA NS 60 mA alarm Model s APIM 10A modules system sensors rating 15 32 V dc 60 mA per circuit Model s IM 10A NT modules rating 15 32 Vdc 1.45 mA NS 37 mA alarm Model s APCR 6A six control module system sensors Model s CR 6A rating 15 32 V dc alarm and rating for relay contact 18 28 V dc A max or 125 V ac 0.5 A compatible with Intelligent Communication Circuit Fire Alarm Control Unit by Mircom Technologies Inc FX 2000 six control module system sensors rating 15 32 V dc alarm and rating for relay contact 18 28 V dc 3 A max 125 V ac 0.5A Model s CR 6A CR 6A FCI CR 6A NT six control module system sensors rating 15 32 V dc alarm and rating for relay contact 18 28 V dc 3 A max 125 V ac 0.5A Model s CR 6A FL control module system sensors Model s SC 6A input 15 31 V dc mA alarm output 18 28 V dc 3 A 63 W 70.7 V ac per circuit and 22.5 W 25 V ac per circuit compatible with Intelligent Communication Circuit Fire Alarm Control Unit by Technologies Inc model FX 2000 control module system sensors input 15 31 V dc 35 mA alarm output 18 28 V dc 3 A 63 W 70.7 ac per circuit and 22.5W 25 V ac per circuit Model s SC 6A SC 6A FCI SC 6A FL SC 6A NT relay system sensors Model s PR 1A operating voltage rating 24 V dc 24 V ac and 120 V ac current rating 15 Max contact rating 7 A 24 V dc 0.35pf and 120 V ac 10 A 250 V ac and 30 V dc resistive load relay system sensors operating voltage rating 10 to 40 V dc 30 mA max contact rating 7 A 24 V dc and 120 V ac 10A 120 V ac 250 V ac and 30 V dc resistive load Model s PR 2A PR 3A relays operating voltage 18 35 V dc 18 35 V ac 115 V ac 230 V ac operating I mA 23 mA 59 mA 150 180 mA contact rating 24 V dc 120 V ac 120V ac 230 V ac 7 A 10 A 1 6 A 7 A Model s R 10EA R 10TA R 14EA R relays operating voltage 18 35 V dc 18 35 V ac 115 V ac 230 V ac operating I mA 36 mA 92 A 220 260 mA contact rating 24 V dc 120 V ac 120V ac 230 V ac 7 A 10 A 1 6 A 7 A Model s R 20EA R 20TA R 24EA R reverse relay module system sensors input 9.5 32 V dc 29 mA relay contacts rated 2 A 30 V dc 0.6 pf 0.5 A 120 V ac 0.6 pf for use with System Sensor smoke detectors Models 2100AT 2112 24AT 2112 24ATR Model s RR1A control modules 15 32 V dc 6.5 mA max Model s CRF 300A b compatible for connection only on the intelligent communication circuit of Mircom Technologies control unit Model FX Secutron control unit Models MR 2400 and MR 2900 and Securiplex control unit Models 1120 and PRO 2000 b M500RA HW b M500RA NT b Module Model s HFS MR HFS MRA modules Model s EM 1RIA rating Communication CCT 15 30 V dc 500 uA standby 500 uA maximum alarm output 2A 30 V A 30 V dc 0.5 A 30 VDC 0.9A 110 V dc 0.9A 125 V dc 0.7A 70.7 V ac 0.3 A 125 V ac 1.5 A 25 V ac 2 A 25 V ac 5 06 54 PM Control Unit Accessories System Certified for Canada modules rated 0.2 mA 15 32 Vdc Model s M500RA FCI b zone interface module system sensors rating 15 32 V dc 2 mA standby 40 mA alarm Model s CZ 6A CZ 6A FCI CZ CZ 6A NT control modules Model s M900CA rating DCL Communication CCT 15 30 Vdc 500uA standby and 3 mA alarm output Class B 2 A Class A 1Amp this module is only compatible for connection only on the intelligent communication circuit of control unit models MR 2100 2200 control modules rated 0.7mA 15 32 Vdc Model s M500SA FCI b control modules system sensors Model s EM 1SRIA rating SLC Communication CCT 15 30 Vdc 560uA standby and mA alarm output Class B 3 A Class A 2 Amp power monitor speaker 70.0 rms 50 W or regulated power supply 24 V dc cards for use with SC 6A input 24 V dc nominal 15 mA Model s SYNC 1A Sensor Model s System Sensor model Notifier ID Code for use with compatible connection on the intelligent communication of Model AFC600 fire alarm system control unit by Notifier either in Flashscan or CLIP mode Sensor model with Fire Control Instruments ID Code for use with only on the intelligent communication circuit of Model 7100 Fire alarm system control unit by Fire Control Instruments Sensor model with Firelite ID Code for connection only on the intelligent communication circuit of Models MS 9200 and MS fire alarm system control unit by Fire Lite Alarms Inc sensor model with Honeywell ID Code for connection only on the intelligent communication circuit of Model DeltaNet FS90 and security system control unit by Honeywell Limited Modules can be installed in the DNRA duct housing Some of these products are covered by S2766 Updated on 2018 02 09