Fire-Lite W-BG12LX(SP) Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-w-bg12lx-sp-data-sheet-2743615980.pdf
Type PDF
Size 807.20 KB
Downloads

Text Preview

W BG12LX W BG12LXSP Wireless Pullstations Fire SWIFT addressable pull station is a dual action pull station with a key lock reset feature that provides one alarm initiating input The pull station features similar design and durable construction characteristics as the counterpart to blend seamlessly throughout the environment device communicates to the FACP through the SWIFT mesh and gateway and is powered by 4 batteries offering a 2 UL listed battery life is fast and straightforward by using a mounting plate that be surface mounted Once the mounting plate is firmly attached the wall the pull station is snapped into place and locked down 3 screws mechanical operation is simple and easy to use in an emer with a PUSH IN PULL DOWN handle that latches in the down to clearly indicate the station has been operated while the appears on top of the handle in bright yellow indicating the operation of the station wireless pull station meets the Americans with Disabilities Act Guidelines ADAAG controls and operating mecha guidelines section 4.1.3 13 and the Americans with Disabili Act ADA requirement for a 5 pound maximum pull force to the pull station and conforms to ANSI UL Standard 38 SWIFT wireless system offers intelligent addressable devices provide secure reliable communication to the Fire Alarm Con Panel FACP across a Class A mesh network Wireless devices an opportunity for applications where it is costly concrete buried wires obtrusive surface mount conduit or dangerous asbestos to use traditional wired devices In both wired and wireless devices can be present on the FACP providing an integrated wired wireless solution for installation potential mesh network within the SWIFT system creates a child parent between the devices so that each device has two par providing a second path for communications on every device If device can no longer operate for any reason the rest of the can still communicate with each other directly or through or more intermediate devices Once an initial mesh network is mesh restructuring automatically occurs to find the stron paths possible within the network SWIFT system also engages frequency hopping to prevent sys interference whether intentional or accidental Each device with part 15 of the FCC rules meaning operation is subject the following two conditions 1 The device may not cause harmful and 2 The device must accept any interference including interference that may cause undesired operation Easy fast wireless installation Participates in a Class A mesh network Built in tri color LED which is visible through the handle of the flashes in normal operation and latches steady red when alarm Handle latches in down position and the word to clearly indicate the station has been operated Maintenance personnel can open station for inspection and setting without causing an alarm condition Standard wheel for setting the SLC address For use in commercial applications Smooth dual action design Wireless Devices Meets ADAAG controls and operating mechanisms guidelines 4.1.3 13 meets ADA requirement for 5lb maximum force Braille text on station handle Meets UL 38 Standard for Manually Actuated Signaling Boxes Highly visible Made of durable polycarbonate material Attractive shape and textured finish Key reset Control Panels ES 50X ES 200X MS 9200UDLS MS 9600 UD LS and Ordering Information W BG12LX Wireless addressable pullstation Requires 4 CR batteries included W BG12LXSP Wireless addressable pullstation Spanish text 4 CR 123A batteries included W GATE Fire Wireless SWIFT Gateway 1 SWIFT Gate is required for each wireless mesh and supports up to 48 detectors or modules and one display driver if required to the SLC loop of a compatible panel using LiteSpeed Power may be supplied by the SLC circuit or via an 24VDC input Use of the 24VDC input may be more convenient for service as it for powering down a gateway without shutting down an SLC loop W DIS D LCD user interface for use with the W GATE wireless and an ANN 80 W Remote Annunciator Connects to 10 30 2018 Page 1 of 2 Transmit RF Power 17 dBm Frequency Range 902 928 MHz Range 32 to 120 0 to 49 10 to 93 Non condensing Type 4 Panasonic CR123A or 4 Duracell DL123A Life 2 year minimum Replacement Upon TROUBLE BATTERY LOW display and during annual maintenance 5.6 142 mm H x 4.2 107 mm W x 2.1 53 mm D Listings and Approvals listings and approvals below apply to the W BG12LX In some certain modules may not be listed by certain approval agen or listing may be in process Consult factory for latest listing sta Listed S711 7150 0075 0503 ID AUBWFSPS Fire Dept COA 6252 6253 6261 Approved FACP via the ANN BUS Both W DIS D and ANN 80 W are to display trouble and supervisory conditions that are to the W GATE and its devices One W DIS D is required each W GATE in a system using the MS 9200UDLS or MS ANN 80 W White 80 character LCD annunciator used with the to display wireless specific events not display ed on the W SD355 intelligent wireless photo detector Ships with B501W included Requires 4 CR 123A batteries included W H355R intelligent wireless rate of rise 135 heat detector with B501W base included Requires 4 CR 123A batter included W SD355T intelligent wireless photo heat detector Ships with CR 123A batteries Requires base W H355 intelligent wireless fixed temperature 135 heat detec Ships with B501W base included Requires 4 CR 123A bat included W MMF Wireless monitor module Used to monitor devices with contact actuation Includes a special cover with a tamper magnet Recommended for installation in a box ordered separately rather than a metal back for best performance Requires 4 CR 123A batteries W CRF Wireless relay module for use with the W GATE wireless Includes a special cover with a built in tamper magnet for installation in an SMB500 WH box ordered rather than a metal backbox for best performance 4 CR 123A batteries included WAV CRL WAV CWL SWIFT Wireless Addressable A V bases 8 CR 123A batteries included Requires a non com ceiling System Sensor L series notification device ordered W SYNC Wireless sync module Requires 4 CR 123A batteries SMB500 WH Optional surface mount backbox SWIFT Tools Programming and diagnostic utility Free download www firelite com For installation on a typically laptop PC an approved version of Windows See Minimum System for SWIFT Tools Requires the W USB radio dongle for communication with SWIFT Wireless devices W USB Wireless USB radio antenna dongle that plugs into the port of a PC running SWIFT Tools The W USB provides a link with SWIFT Wireless devices that are within 20 feet and have not formed a mesh Alternately the devices have formed a mesh bringing the PC W USB range 20 ft of the gateway for that mesh will allow SWIFT to acquire information on all devices in that mesh including signal strength for all links W BATCART Wireless battery cartridge 10 pack For use with pullstations and A V bases Alarms System Sensor and SWIFT are registered trademarks of LiteSpeed is a trademark of Honeywell International Inc Microsoft and are registered trademarks of Microsoft Corporation Duracell is a trademark of Duracell U S Operations Inc Panasonic is a registered of Panasonic Corporation by Honeywell International Inc All rights reserved Unauthorized use of this is strictly prohibited document

Related Files