Fire-Lite W-BG12LXSP Instruction Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-w-bg12lxsp-instruction-manual-1486253709.pdf |
---|---|
Type | |
Size | 3.32 MB |
Downloads |
Text Preview
INSTALLATION AND MAINTENANCE INSTRUCTIONS Wireless Pull Station Operating Voltage Current Draw Operating Current Transmit RF Power Frequency Range Range Type Life Replacement VDC mA LED on dBm MHz to 120 0 to 49 to 93 Non condensing Panasonic CR123A or 4 Duracell DL123A year minimum TROUBLE BATTERY LOW display and or during annual maintenance 142 mm H x 4.2 107 mm W x 2.1 53 mm D Cartridge W BATCART FireLite Place CT 06472 203.484.7161 INSTALLING pull station must be installed in compliance with the control panel sys installation manual the SWIFT Wireless Gateway Manual applicable standards national and local Fire codes and the requirements of the Authority Having Jurisdiction Regular testing of the devices should be in accordance with the appropriate NFPA standards Pull stations offer performance when installed in compliance with the National Fire Association NFPA see NFPA 72 This manual should be left with the owner user of this equipment DESCRIPTION W BG12LXSP wireless addressable pull station is a UL38 compliant dual manual pull station with a key lock reset feature intended for use with wireless gateway or wireless fire alarm control panel FACP See Figure 1 provides Fire Lite panels one addressable alarm initiating input The device through a robust bi directional mesh network to the gateway FACP Rotary dial switches are provided for setting the pull station See Figure 2 Operating instructions are molded into the pull station The wireless pull station meets the Americans with Disabilities Act Guidelines ADAAG controls and operating mechanisms guide section 4.1.3 13 the Americans with Disabilities Act ADA require for a 5 lb maximum pull force to activate the pull station and conforms ANSI UL Standard 38 offer different feature sets across the various models As a result cer features may be available on some control panels but not on others The feature sets available with the wireless pull station include An LED on the wireless pull station is controlled by the panel to indicate status Operational modes include red green and amber colors in solid or blink patterns REQUIREMENTS ensure proper operation this module shall be connected to a compatible system control panel list available from Fire Lite 1 WIRELESS MANUAL PULL STATION DOOR battery door includes a magnet for activation and tamper resistance See 2 The battery door magnet activates communication to the panel the battery door must be installed and closed for the pull station work properly The magnet also activates a tamper fault at the panel if the door is opened Do NOT remove this magnet REPLACEMENT battery levels on the wireless devices are displayed as a trouble in the Therefore when the message BATTERY LOW is displayed the battery in the device This message is an indication that approxi one week of battery life remains replace the batteries in a wireless device use the following steps Have 4 CR123A or DL123A batteries available Use the key to unlock and open the pull station door Open the battery compartment See Figure 2 Remove the used batteries and replace with new batteries Batteries can inserted directly into the pull station or inserted as a set of 4 batteries in a battery cartridge available from Fire Lite See Figure 2 battery compartment and cartridge indicate the correct orientation of batteries Carefully align the batteries with these markings and do not them into place Close the battery compartment cover Close and lock the pull station door 2 BATTERY INSTALLATION Compartment With Door Open Compartment Door in the Closed Up Position Compartment Door in the Open Down Position Address Switches Cartridge technologies can exhibit communication disruption if devices are too close together To avoid this form of disruption SWIFT devices not be placed closer than 2 feet 60 cm apart without an intervening For specific information regarding pull station placement refer to 72 ADAAG and ADA mount the wireless pull station attach the wireless pull station mounting to a permanent structure The mounting plate can be surface mounted avoid interference with the wireless network metal electrical boxes are NOT Do not detach the door of the pull station during installation door of the pull station cannot be reattached to the main housing after the station has been installed Place the pull station onto the mounting plate secure by tightening all three 3 mounting screws inside the door of the housing using a 1 Phillips head screwdriver See Figure 3 Do not attach the pull station to temporary structures such that the could be altered 3 DEVICE MOUNTING activate the dual action pull station in and pull down on the handle The word appears after handle is pulled down This will remain until the pull sta tion is reset reset the pull station Insert the key into the lock and rotate 1 4 turn counterclockwise Open the door until the handle returns to normal Close and lock the door Closing the door automatically resets the switch to the posi Open ing the door will not activate or deactivate the alarm switch of these products in combination with non Honeywell products in a wireless mesh network or to access monitor or control devices in a wireless mesh nework via the internet another external wide area network may require a separate license from Sipco LLC For more information contact Sipco LLC or Ipco LLC at 8215 Roswell Rd Building 900 950 Atlanta GA 303350 or at www sipocollc com or www intusiq com device complies with part 15 of the FCC Rules Operation is subject to the following two conditions This device may not cause harmful interference and This device must accept any interference received including interference that may cause undesired operation FEDERAL DE TELECOMUNICACIONES device utilizes the Honeywell915 rev A radio module and complies with IFETEL standard s IFT RCPHOSW14 1983 Do not make changes to the equipment Changes or modifications not expressly approved by the manufacturer could void the user authority to operate the equipment STATEMENT STATEMENT and SWIFT are registered trademarks of Honeywell International Inc Fire Lite 11 15 2017 DE INSTALACI Y MANTENIMIENTO Estaci de alarma inal m de funcionamiento m de corriente promedio de funcionamiento m de transmisi de RF de radiofrecuencia de temperatura de bater de la bater de la bater VCC mA LED encendido dBm MHz a 120 0 a 49 a 93 sin condensaci Panasonic CR123A o 4 Duracell DL123A 2 a visualizar BATER BAJA o con el mantenimiento anual 142 mm altura x 4,2 107 mm ancho x 2,1 53 mm espesor de la bater W BATCART FireLite Place CT 06472 1 203 484 7161 DE LA INSTALACI estaci de alarma debe instalarse de acuerdo con el manual de instalaci sistema del panel de control el manual de puerta de enlace inal SWIFT normas de la NFPA aplicables los c de incendios nacionales y locales y requisitos de la ATJ autoridad que tiene jurisdicci Las pruebas regulares de dispositivos deben realizarse de acuerdo con las normas apropiadas de la NFPA estaciones de alarma ofrecen el m rendimiento cuando se instalan de con las normas de la Asociaci Nacional de Protecci contra Incendios Consulte NFPA 72 Este manual debe entregarse al propietario o usuario del equipo GENERAL W BG12LXSP estaci de alarma direccionable e inal es una estaci