Fire-Lite Wheelock AS Series Audible Strobe Devices & AH Series Audible Devices
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-wheelock-as-series-audible-strobe-devices-ah-series-audible-devices-4901263758.pdf |
---|---|
Type | |
Size | 735.98 KB |
Downloads |
Text Preview
July 2 2004 cid 127 G 510 Series Audible Strobe Devices AH Series Audible Devices Audio Visual Devices 356 5946 Fire Audible Strobe Audible NOTES Strobes are designed to flash at 1 flash per second minimum the Regulated Voltage Range Note that NFPA 72 1999 a flash rate of 1 to 2 flashes per second and ADA specify a flash rate of 1 to 3 flashes per second All candela ratings represent minimum effective Strobe intensity on UL Standard 1971 AS Series Strobe products are listed under UL Standard 1971for use with a temperature range of 32 F to 120 F O C to C and maximum humidity of 93 2 AH 24 Series horns are listed under UL Standard 464 for audible appliances indoor use only AH 24WP Series audible appliances are listed under UL Stan 464 for indoor outdoor use with a temperature range of F to 150 F 35 C to 66 C and maximum humidity of 95 Voltage Range is the newest terminology by UL to identify the voltage range Prior this UL used the terminology Voltage Range patented 2 wire Series AS Audible Strobe Appli and Series AH Audible Devices offer more features with current draw options for wall mount models include 1575 cd or patented MCW multi candela wall strobes with field candela settings of 15 30 75 110cd mount models incorporate Wheelock patented MCC multi ceiling strobe with field selectable intensities of 15 30 audible provides a selectable choice of either a continuous or temporal pattern Code 3 when constant voltage from a Alarm Panel FACP is applied Each tone has 3 dBA settings choose from used with the Wheelock Series SM or DSM Sync Module or supply with patented Wheelock sync protocol synchroni of the continuous horn tone provides the temporal code 3 mandated by NFPA 72 simultaneously for all audible appli This ensures a distinct temporal code 3 pattern when 2 more audibles are within hearing distance If not synchro the temporal sound could overlap and not be distinctive at same time the strobes will be synchronized This provides the to comply with ADA guidelines concerning photosensitive and the NFPA standards when installing 2 or more visual within the field of view All of this plus the ability to the audible is achieved by using only 2 wires ADA NFPA UFC ANSI Compliant AS Series Audible Strobe Devices are available in wall ceiling mount models mount models offered are available with Field Selectrable Settings of 15 30 75 110cd or 1575cd single candela mount models offered are available with field candela settings of 15 30 75 95cd Selectable Continous Horn or Temporal Code 3 3 Selectrable dBA settings 99 95 abd 90 dBA in both tones Patented 2 Wire Audible Strobe Appliance Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage 12 and 24 VDC models with wide UL Voltage Range filtered DC or unfiltered FWR input voltage Synchronize with Wheelock SM DSM or power supply with Wheelock sync protocol Fast installation with IN OUT screw terminals using 12 and 18 wires Alarms is a Honeywell company document is not intended to be used for installation purposes We try to keep our product up to date and accurate We cannot cover all specific applications or anticipate all All specifications are subject to change without notice more information contact Fire cid 127 Lite Alarms One Fire Lite Place Northford Connecticut 06472 800 627 3473 Toll Free FAX 877 699 4105 07 02 04 Page 1 of 4 READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING OR APPLYING THIS PRODUCT FAILURE TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION INSTALLATION AND OR OPERATION OF THESE IN AN EMERGENCY SITUATION WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH YOU AND OR OTHERS INFORMATION APPROVALS MEA CSFM FM BFP 31 75 on Axis 75 on Axis to data sheet DN6111 for Mounting Options Due to continous development of our products specifications and offerings are subject to change without in accordance with Notifier standard terms and conditions X X X X X WALL CEILING A B D E F G H J N O R X X WALL CEILING A B D E F G H J N O R X X WALL CEILING WALL CEILING 1 RATINGS PER UL 1971 33.0 33.0 75 on axis 17.5 75 on axis 33.0 MODELS POWER SUPPLY L E R UT T AGE R AGE AN R E NT 24 VDC ING T IONS 2 DBA RATINGS FOR 12 VDC 24 VDC SERIES 12 24 VDC AUDIBLE VOLUME PER UL 10 FT 10 FT Sync Module is rated for 3.0 amperes 24 VDC Sync Module is rated for 3.0 amperes per circuit The number of interconnected DSM modules is twenty 33.0 31 3 Horn DIAGRAMS device non synchronized devices synchronized with SM Module single Class Style Y circuit audible silence feature 2 of 4 DF 51898 cid 127 07 02 04 DIAGRAMS and AH devices synchronized with DSM Module dual Style Z circuit with NO audible silence feature and AH devices synchronized multiple DSM Modules WIRING SHOWN OF TWENTY 20 DSM MODULES AS AH must be set on continuous horn tone and connected to the SM DSM Sync Module to achieve synchronized temporal Code 3 3 AVERAGE RSM CURRENT VDC MODELS AS 241575W MOUNT AUDIBLE STROBE MODELS MOUNT STROBE MODELS 95cd 115cd 177cd vdc 0.330 0.355 dBA dBA dBA vdc 0.213 vdc 0.177 vdc 0.309 0.340 vdc 0.195 vdc 0.145 vdc 0.306 0.335 vdc 0.185 vdc 0.132 VDC MODELS VDC MODELS VDC MODELS MOUNT AS 121575W AS 121575W AS 121575W