Fire-Lite Wheelock® Exceder™ Horns and Strobes
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-wheelock-exceder-horns-and-strobes-2904687351.pdf |
---|---|
Type | |
Size | 684.11 KB |
Downloads |
Text Preview
Wheelock Exceder and Strobes Wheelock Exceder Series of notification appliances a sleek modern design and numerous features includ eight candela options in one appliance low current draw tools needed for setting changes 12 24 VDC operation mounting base and multiple mounting options with an audible feature 3 sound settings 90 95 99 All switches to change settings can be set without the use a tool and are located behind the appliance to prevent tam Wall models feature voltage test points to take read with a voltage meter for troubleshooting and AHJ Wheelock Exceder Series of wall and ceiling notifica appliances feature a Universal Mounting Base UMB to simplify the installation and testing of horns and combination horn strobes The separate universal base can be pre wired to allow full testing of circuit before the appliance is installed and the surface is fin It comes complete with a contact cover for protection dirt dust paint and damage to the contacts The con cover also acts as a shunting device to allow pre wire test for common wiring issues contact cover is polarized to prevent it from being installed and prevents the appliance from being installed it is on the UMB When the contact cover is removed the will show an open until the appliance is installed The allows for consistent installation and easy replacement of if required Wall models provide an optional locking for extra secure installation while the ceiling models a captive screw to prevent the screw from falling during Multiple voltages Voltage test points for quick troubleshooting and easy spot wall models only 3 audible settings 90 95 99 dB 8 Candela settings Wall 15 1575 30 75 95 110 135 185 Ceiling 15 30 60 75 95 115 150 177 Finger slide switches Sleek modern aesthetics Common base for wall and ceiling with 5 mounting options 1 gang 2 gang 4 inch square 3.5 inch octagonal 4 inch octagonal and Requirements Synchronize using Wheelock Sync Modules or panels with Wheelock patented sync protocol Compatible with UL Voltage using filtered VDC unfiltered VRMS input voltage Strobes produce one flash per second over the Regulated range cid 129 A1 10 Devices Notes All candela ratings represent minimum effective strobe based on UL Standard 1971 Series Exceder Strobe products are Listed under UL Stan 1971 and 464 for indoor use with a temperature of 32 to 120 0 to 49 and maximum humid of 93 2 UL 464 85 UL 1971 Series Exceder horns are under UL Standard 464 for audi signal appliances Indoor use only Product naming conventions The Exceder line model break down into easy to remember codes Horn ST Strobe HS Horn strobe C Ceiling W White and R Red So can be read as Red Ceiling mount and is wall mount Refer to your fire alarm panel or power supply manual when the number of devices allowed per circuit Specifications notification appliances shall be Wheelock Exceder Series Audible Strobe appliances Series ST Visual Strobe appli and Series HN Audible appliances or approved equals Series HS and ST Strobes shall be listed for UL Standard Emergency Devices for the Hearing Impaired for Indoor Protection Service The Series HS and HN Audibles shall UL Listed under Standard 464 Fire Protective Signaling Series shall meet the requirements of FCC Part 15 Class B inputs shall be compatible with standard reverse polarity of circuit wiring by a Fire Alarm Control Panel with the ability to operate from 8 to 33 VDC Indoor models shall incorporate voltage test points for easy volt inspection Series HS Audible Strobe and ST Strobe appliances shall a flash rate of one flash per second over the Regu Voltage Range and shall incorporate a Xenon flashtube in a rugged Lexan lens The Series shall be of low design Where Multi Candela appliances are specified strobe intensity shall have 8 field selectable settings at 15 05 03 2010 Page 1 of 2 30 75 95 110 135 185 candela for wall mount and 30 60 75 95 115 150 177 candela for ceiling mount selector switch for selecting the candela shall be tamper The 15 75 candela strobe shall be specified when 15 UL Standard 1971 Listing with 75 candela on axis is e g ADA compliance Appliances with candela set shall show the candela selection in a visible location at all when installed audible shall have a minimum of three field selectable set for dBA levels and shall have a choice of continuous or Code 3 audible outputs OPTIONS Series HS Audible Strobe ST Strobe and Series HN Audi shall incorporate a patented Universal Mounting Base that allow mounting to a single gang double gang 4 square octagonal 4 octagonal or 100mm European type back Two wire appliance wiring shall be capable of directly to the mounting base Continuity checking of the NAC circuit prior to attaching any notification appliances be allowed Product shall come with contact cover to pro contact springs Removal of an appliance shall result in a fault condition by the Fire Alarm Control Panel The mounting base shall be the same base among all strobe horn strobe wall and ceiling models All notifica appliances shall be backwards compatible SPECIFICATIONS Series HS and ST wall models shall have a low profile 5.24 H x 4.58 W x 2.19 D Series HN wall shall 5.24 H x 4.58 W x 1.6 D The Series HSC and STC Ordering Information been round and have a low profile with a diameter of x 2.63 D Series HNC ceiling shall have a diameter of x 1.50 D synchronization is required the appliance shall be com with Wheelock SM DSM Sync Modules Whee Power Supplies or other manufacturer panels with Wheelock Patented Sync Protocol The strobes shall drift out of synchronization at any time during operation If sync protocol fails to operate the strobe shall revert to a flash rate and still maintain one flash per over its Regulated Voltage Range The appliance shall be designed so that the audible signal may be silenced maintaining strobe activation when used with Whee synchronization protocol and Codes in this series comply with UL Standard 1971 UL 464 California State Fire Marshal CSFM and ULC Listings listings and approvals apply to the modules specified in document In some cases certain modules or applications not be listed by certain approval agencies or listing may in process Consult factory for latest listing status UL Listed S5391 Strobes E5946 Horns Horn strobes ULC Listed CSFM Listed 7125 0785 168 Candela VDC Options 30 60 75 95 115 150 177 30 60 75 95 115 150 177 15 75 30 75 95 110 135 185 15 75 30 75 95 110 135 185 15 75 30 75 95 110 135 185 15 75 30 75 95 110 135 185 Mounting Base Mounting Base Mounting Base Mounting Base Strobes VDC models feature 15 and 15 75 settings Due to continuous development of Cooper Wheelock products specifications and offerings are sub to change without notice in accordance with Cooper Wheelock Inc dba Cooper Notification standard and conditions Mounting Base Mounting Base Mounting Base Mounting Base Mounting Base Mounting Base Mounting Base Mounting Base 30 60 75 95 115 150 177 30 60 75 95 115 150 177 Alarms is a registered trademark of Honeywell International Inc is a trademark and Wheelock is a registered trademark of Cooper by Honeywell International Inc All rights reserved Unauthorized use this document is strictly