Fire-Lite Wheelock NS NS4 Series Horn Strobes & NH Series Horns
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-wheelock-ns-ns4-series-horn-strobes-nh-series-horns-8132964750.pdf |
---|---|
Type | |
Size | 721.71 KB |
Downloads |
Text Preview
Wheelock NS NH Series Series Horn Strobes Series Horns Wheelock Series NS Horn Strobe Appliances will satisfy all requirements for indoor wall mount applications Series NH Horn and the horn portion of the Series NS a selectable continuous horn tone or temporal pattern 3 with selectable dBA settings of 90 or 95 dBA options include 1575cd or Wheelock patented Multi strobe with field selectable candela settings of 15 30 versatile Horn Strobe Appliances may be synchronized used in conjunction with the Wheelock SM or DSM Sync or a Power Supply with the Wheelock patented Sync Additionally the audible may be silenced while main strobe activation models of the Series NS and NH are designed for maxi performance reliability and cost effectiveness while or exceeding the latest requirements of NFPA 72 117.1 UFC and UL Standards 1971 and 464 as well as ADA requirements concerning photosensitive epi Field selectable Candela settings 15 30 75 110cd 24 VDC models or 1575cd in 12 or 24 VDC Selectable Continuous Horn or Temporal Code 3 2 selectable dBA settings of 90 and 95 dBA in both tones 12 and 24 VDC models with UL Voltage using DC or unfiltered VRMS input voltage Patented Universal Mounting Plate Wall mount ADA NFPA UFC ANSI compliant Complies with OSHA 29 Part 1910.165 NH Horn is selectable 12 or 24 VDC in 1 unit Synchronize with Wheelock SM or DSM Sync Module or Power Supply with built in Sync Protocol Patent Pending Universal Mounting Plate for single gang 4 10.16c m square or 100 mm European or Wheelock SHBB shallow surface backbox Fast installation with IN OUT screw terminals using 12 to AWG wires Notes Strobes are designed to flash at 1 flash per second mini over their Voltage Range Note that NFPA specifies a flash rate of 1 to 2 flashes per second and Guidelines specify a flash rate of 1 to 3 flashes per All candela ratings represent minimum effective Strobe based on UL Standard 1971 Series NS Strobe products are listed under UL Standard for indoor use with a temperature range of 32 to 0 to 49 and maximum humidity of 93 2 Series NH Horns are listed under UL Standard 464 for audi signal appliances indoor use only G 505 Devices Horn Strobe Horn Indicator of Strobe Lens Voltage Range is the newest terminology used UL to identify the voltage range Prior to this change UL the terminology Voltage Range WARNING PLEASE READ THESE AND ASSOCIATED INSTRUCTIONS CAREFULLY USING SPECIFYING OR APPLYING PRODUCT FAILURE TO COMPLY WITH OF THESE INSTRUCTIONS CAUTIONS WARNINGS COULD RESULT IN IMPROPER INSTALLATION AND OR OF THESE PRODUCTS IN AN SITUATION WHICH COULD IN PROPERTY DAMAGE AND INJURY OR DEATH TO YOU AND OR 1 Ratings Per UL Standard 1971 75 on axis 4 18 08 Page 1 of 4 2 dBA Ratings for Series NS NH Horn 4 Average RMS Current Ratings VDC VDC VDC VDC VDC VDC 95 dBA 90 dBA 5 Average Mean Current Ratings NH Horn 24 Models 95 dBA 90 dBA 6 Sync Models Power Supply 24 VDC SM Sync Module is rated for 3.0 amperes 24 VDC Sync Module is rated for 3.0 amperes per circuit The max number of interconnected DSM Modules is twenty 20 Volume 10ft per UL dBA 10ft 24VDC 12VDC 24VDC 3 Horn 3 Average RMS Current Ratings with High 95 dBA Setting VDC VDC VDC VDC VDC VDC with Low 90 dBA Setting Average RMS Current is per UL average RMS method and Mean Current is per UL average mean method NH use average mean current For rated in Rush and Peak across UL Listed voltage range for both filtered DC and FWR see installation instructions 7 UL Maximum Current NS NH VDC 95 dBA 90 dBA NS NH VDC 95 dBA 90 dBA Mount Strobe Models Mount RMS current ratings are per UL average method UL max current rating is the max RMS current within the listed voltage 16 33V for 24V units For strobes the max current is usually at the minimum listed 16V for 24V units For audibles the current is usually at the listed voltage 33V 24V units For unfiltered FWR ratings see instructions 2 of 4 DF 51988 A 4 18 08 WARNING CONTACT WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS P83983 SERIES P84234 SERIES NS 12 AND 24 VDC SINGLE CANDELA MODELS P83600 SERIES NH AND INFORMATION SHEET P82380 ON THESE PRODUCTS THESE DOCUMENTS UNDERGO CHANGES IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THE PRODUCTS MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO OR INSTALLING THESE PRODUCTS INCLUDING TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY SOURCES FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM APPLIANCES ON THOSE CIRCUITS COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON FIELD OF VIEW ADDING REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELLA SETTINGS WILL CURRENT DRAW RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE CAPACITY OF THE POWER SOURCES OR FUSES THE VOLTAGE APPLIED TO THE PRODUCTS MUST BE WITHIN THEIR VOLTAGE OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES THESE APPLIANCES ARE NOT DESIGNED TO BE USED ON CODED SYSTEMS IN WHICH THE VOLTAGE IS CYCLED ON AND OFF FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION COULD RESULT IN IMPROPER INSTALLATION APPLICATION AND OR PROPERTY AND SERIOUS INJURY OR DEATH TO YOU AND OR OTHERS CONDUCTOR SIZE AWG LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION TO DESIGN AND INSTALLATION OF THESE PRODUCTS PARTICULARLY IN RETROFIT Diagrams FACP EOLR APPLIANCE OUT 1 IN 1 1 AUDIBLE AUDIBLE OUT 2 IN 2 2 RETURN AND NH APPLIANCES SYNCHRONIZED WITH DSM DUAL CLASS NAC CIRCUIT WITH NO SILENCE FEATURE Audible AND NH APPLIANCES WITH SM MODULE CLASS NAC CIRCUIT WITH SILENCE FEATURE NS NH must be set on Code 3 horn to achieve syn