FireLite MRP-2002(C) Agent Release Control Panel

File Preview
File Preview
Click below to download for free

File Data

Name firelite-mrp-2002-c-agent-release-control-panel-7639012584.pdf
Type PDF
Size 1.03 MB
Downloads

Text Preview

MRP 2002C Release Control Panel MRP 2002C is a six zone FACP for single and dual haz agent releasing applications The MRP 2002C provides fire detection signaling and protection for commercial and institutional buildings requiring agent based The MRP 2002C is compatible with System Sen i3 detectors which are conventional smoke detectors that transmit a maintenance trouble signal to the FACP indicat the need for cleaning and a supervisory signal the ambient temperature falls below the detector rating approximately 45 7.22 In addition the control panel compatible with conventional input devices such as two wire detectors four wire smoke detectors pull stations devices tamper switches and other normally open devices Refer to the Fire Device Compatibility for a complete listing of compatible devices outputs are programmable as NACs Notification Appli Circuits or releasing circuits Three programmable relays factory programmed for Alarm Trouble and and 24 VDC special application resettable and power outputs are also included on the main board The MRP 2002C supervises all wiring AC volt battery charger and battery level of a compatible smoke detector or any normally fire alarm initiating device will activate audible and visual devices illuminate an indicator display alarm infor on the panel LCD sound the piezo sounder at the activate the FACP alarm relay and operate an optional used to notify a remote station or initiate an auxiliary function Listed to Standard ULC S527 11 FM Approved Designed for agent releasing standards NFPA 12 12A 12B 2001 Meets International Building Code IBC seismic require Disable Enable control per input zone and output zone Extensive transient protection Dual hazard operation Adjustable pre discharge discharge and waterflow delay Cross zone double interlock capability Six programmable Style B Class B IDCs Initiating Device System Sensor i3 series detector compatible Four programmable Style Y Class B output circuits spe application power Strobe synchronization System Sensor Wheelock Gentex Faraday Amseco Three programmable Form C relays DF 60443 B2 Control Panels 7.0 amps total 24 VDC output current Resettable and non resettable output power Built in Programmer ANN BUS for connection to optional devices up to 8 total any of the following N ANN 80 Remote LCD Annunciator N ANN I O LED Driver N ANN S PG Printer Module only one allowed per panel ANN RLY Relay Module ANN LED Annunciator Module built in 80 character LCD display backlit Real time clock calendar with daylight savings time control History log with 256 event storage Piezo sounder for alarm trouble and supervisory 24 volt operation Low AC voltage sense Outputs Programmable for Releasing Circuits or NACS NACs programmable for Silence Inhibit Strobe Synchronization Selective Silence horn strobe mute Temporal or Steady Signal Silenceable or Non silenceable Release Stage Sounder Automatic battery charger with charger supervision Optional Trim Ring TR CE red for semi flush mounting the 8 31 2016 Page 1 of 4 Optional CAC 5X Class A Converter Module for Outputs Optional 4XTMF Municipal Box Transmitter Module Optional Digital Alarm Communicators 411 411UD IDCs Optional ANN SEC card for a secondary ANN BUS AND SOFTWARE Custom English labels per point may be manually entered selected from an internal library file Programmable Abort operation Three programmable Form C relay outputs Pre programmed and custom application templates Continuous fire protection during online programming at the panel Program Check automatically catches common errors not to any zone or input point INTERFACE Real time clock calendar with automatic daylight savings 80 character LCD display with backlighting ANN Bus for connection to annunciators or remote indica Audible or silent walk test capabilities Piezo sounder for alarm trouble and supervisory and Indicators INDICATORS FIRE ALARM red SUPERVISORY yellow TROUBLE yellow AC POWER green ALARM SILENCED yellow DISCHARGED red PRE DISCHARGE red indicator ABORT yellow indicator BUTTONS ACKNOWLEDGE SIGNAL SILENCE SYSTEM RESET lamp test ALARM SIGNAL Power TB1 MRP 2002C 120 VAC 60 Hz 3.66 amps Wire size minimum 14 AWG 2.0 mm2 with 600V insula Supervised nonpower limited sealed lead acid only J12 Maximum Charging Circuit Normal Flat Charge 27.6 1.4 amp Supervised nonpower limited Maximum Charger Capacity 18 Amp Hour battery two Amp Hour batteries can be housed in the FACP cabinet batteries require separate battery box such as the or BB 55 Minimum Battery Size 12 Amp Hour Device Circuits TB4 and TB6 Alarm Zones 1 5 on TB4 Alarm Zone 6 on TB6 Supervised and power limited circuitry 2 of 4 Canadian DF 60443 B2 8 31 2016 Style B Class B wiring with Style D Class A option Normal Operating Voltage Nominal 20 VDC Alarm Current 15 mA minimum Short Circuit Current 40 mA max Maximum Loop Resistance 100 Ohms End of Line Resistor 4.7K Ohms 1 2 watt PN 71252 Standby Current 4 mA to the Fire Device Compatibility Document for listed devices Appliance and Releasing Circuit s TB5 and Four Output Circuits Style Y Class B or Style Z Class A with optional con module Special Application power Supervised and power limited circuitry Normal Operating Voltage Nominal 24 VDC Maximum Signaling Current 7.0 amps 3.0 amps special 300 mA regulated maximum per NAC End of Line Resistor 4.7K Ohms 1 2 watt PN 71252 Max Wiring Voltage Drop 2 VDC to the Fire Device Compatibility Document for com listed devices Relays Programmable TB8 Relay 1 factory default programmed as Alarm Relay Relay 2 factory default programmed as fail safe Trouble Relay 3 factory default programmed as Supervisory Relay Relay Contact Ratings 2 amps 30 VDC resistive 0.5 amps 30 VAC resistive Trouble Input J6 Auxiliary Trouble Input is an open collector circuit which be used to monitor external devices for trouble conditions can be connected to the trouble bus of a peripheral such as power supply which is compatible with open collector cir Application Resettable Power TB9 Operating Voltage Nominal 24 VDC Maximum Available Current 500 mA appropriate for 4 wire smoke detectors see note Power limited Circuitry to the Fire Device Compatibility Document for com listed devices Total current for resettable power nonresettable power Output Circuits must not exceed 7.0 amps Application Resettable or Nonresettable Power Operating Voltage Nominal 24 VDC Maximum Available Current 500 mA see note 1 Power limited Circuitry Jumper selectable by JP31 for resettable or nonresettable to the Fire Device Compatibility Document for com listed devices Line Information Six zone 24 volt Agent Release Control Panel backbox power supply technical manual and a post operating instruction sheet for single and dual agent releasing applications

Related Files