System Sensor 2W-MOD2

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-2w-mod2-4827516390.pdf
Type PDF
Size 1.26 MB
Downloads

Text Preview

Voltage Voltage Standby Current Alarm Current Contact Ratings Volts Power limited Volts Power limited of applied voltage 12 detectors on loop Amp 36 V DC Resistive Contact Ratings 2 Amp 30 V DC Resistive Reset Voltage Reset Time Temperature Range 14 to 122 10 to 50 Humidity Range Temperature Range Communication Cycle Walk Test Available to 95 RH non condensing to 158 to 70 minutes after power up or panel reset minutes after power up or panel reset Volts sec inches inches inches pound packaging compatibility loop voltage loop voltage loop resistance loop ripple Loading Capacitance Alarm current Reset Voltage Delay Alarm reset time normal load current Type Device style identifier A detectors per zone Volts Volts ohm Vpp mF mA V sec mA K 0.25W 5 D 2W and 2WT 2WTR 2WTA NOTE When used with the RRS reversal relay synchroniza module and the 2W a maximum of 12 2WTA detec are allowed per zone Limited Warranty Sensor warrants its enclosed product to be free from defects in and workmanship under normal use and service for a period three years from date of manufacture System Sensor makes no other warranty for the enclosed product No agent representative or employee of the Company has the authority to increase or alter obligations or limitations of this Warranty The Company obliga of this Warranty shall be limited to the replacement of any part of product which is found to be defective in materials or workman under normal use and service during the three year period com with the date of manufacture After phoning System Sensor free number 800 SENSOR2 736 7672 for a Return Authorization send defective units postage prepaid to System Sensor Returns RA 3825 Ohio Avenue St Charles IL 60174 include a note describing the malfunction and suspected cause failure The Company shall not be obligated to replace units which found to be defective because of damage unreasonable use modi or alterations occurring after the date of manufacture In no shall the Company be liable for any consequential or incidental for breach of this or any other Warranty expressed or implied even if the loss or damage is caused by the Company or fault Some states do not allow the exclusion or limita of incidental or consequential damages so the above limitation or may not apply to you This Warranty gives you specific legal and you may also have other rights which vary from state to state Statement device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to pro reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help System Sensor AND MAINTENANCE INSTRUCTIONS Test Maintenance Module 2W MOD2 Installing information is included as a quick reference installa guide Refer to the control panel installation manual detailed system information If the modules will be in in an existing operational system inform the opera and local authority that the system will be temporarily of service Disconnect power to the control panel before the modules This manual shall be left with the owner user of equipment Description 2W MOD2 allows a control panel to receive a for signal from two i3 series smoke detec model numbers 2W 2WT 2WTA and 2WTR module uses a form C zone relay to initiate of sen and trouble a form A zone alarm relay and second form A zone relay to indicate loop fault see Figure An EZ Walk Test puts all detectors on the loop into a Walk mode for easy verification of detector loop wiring 1 relay form C relay form A trouble relay form A trouble trouble trouble and trouble and loop trouble and Maintenance Freeze OFF Location 7 N O 8 Common 9 N C connected terminals and 11 connected between 10 and 12 2 Module front view LED LED LED Walk Test LED on the module provide a local visual indica of the module status es maintenance module allows two wire smoke detectors to used on any electrically compatible four wire control panel 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 If two i3 detectors are used in conjunction a style D initiating circuit the 2W must be to provide that capability Ground fault on a mod two wire loop can be indicated at a control panel if control panel is capable of ground fault detection on power supply to the module and meets NFPA 72 ground indication requirements for initiating device circuits installer must verify that capability 3 Module LED modes COLOR LED 1 sec ON 1 sec OFF LED 1 sec ON 1 sec OFF on Detectors loop do not have capability on One or more on loop have capability not applied or not operating on loop in alarm or more detectors of sensitivity or in Trouble on loop not alarm maintenance Freeze Trouble LED 0.5 sec ON 0.5 sec OFF wiring fault Walk Test mode wiring normal module has loop trouble restoration detection If the trouble open loop doesn exist any more the mod will restore to standby condition with a maximum delay 1 minute There is no delay in loop trouble detection an alarm occurs while the module is indicating mainte the alarm will supercede maintenance the green LED remains ON no blinking three minutes af applying power it means that the module has determined no detector on its loop has communication capability this condition the detectors are still capable of initiating and loop trouble at the module However maintenance freeze trouble will not be indicated at the module and walk test will not be available If i3 detectors are installed the loop verify wiring and system operation NFPA loop Style D wiring the EOL resistor is provided to the module An external EOL resistor must be connected at the last detector on the loo

Related Files