System Sensor B210LP Plug-in Detector Base INSTALLATION AND MAINTENANCE INSTRUCTIONS

File Preview
File Preview
Click below to download for free

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Plug in Detector Base Temperature Range inches 155 mm 102 mm square box with or without plaster ring Minimum Depth 1.5 inches 38 mm Octagon Box Minimum Depth 1.5 inches 38 mm Octagon Box Minimum Depth 1.5 inches 38 mm Gang Box Minimum Depth 1.5 inches 38 mm to applicable sensor Operating Temperature Range 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 1 TERMINAL LAyOUT PROOF 2 MOUNTINg DETECTOR TO BOx INSTALLINg thoroughly read the system wiring and installation manuals and man System Smoke Detectors Application Guide which provides detailed in on detector spacing placement zoning and special applications of these manuals are available from System Sensor or through a Sys Sensor distributor DESCRIPTION B210LP is a plug in detector base intended for use in a 2 wire intelligent sys with screw terminals provided for power and and remote annuncia connections Communication takes place over the power and lines TERMINALS Remote Annunciator Annunciator detector base mounts directly to 31 2 and 4 inch octagon boxes 4 inch boxes with or without plaster rings and single gang boxes To mount the decorative ring by turning it in either direction to unhook the then separate the ring from the base Install the base on the box using screws supplied with the junction box and the appropriate mounting slots the base the decorative ring on the base and rotate it in either direction until it into place see Figure 2 WIRINg gUIDELINES wiring must be installed in compliance with all applicable local codes any special requirements of the authority having jurisdiction using the wire size The conductors used to connect smoke detectors to control and accessory devices should be color coded to reduce the likelihood wiring errors Improper connections can prevent a system from responding in the event of a fire signal wiring the wiring between interconnected detectors it is recom that the wire be no smaller than AWG 18 However the screws and plate in the base can accommodate wire sizes up to AWG 12 The of twisted pair wiring or shielded cable for the power and loop is to minimize the effects of electrical interference shielded cable is used the shield connection to and from the detector must continuous by using wire nuts crimping or soldering as appropriate for a connection electrical connections by stripping about 3 8 inch 10 mm of insulation the end of the wire use strip gauge molded in base sliding the bare end the wire under the clamping plate and tightening the clamping plate screw not loop the wire under the clamping plate zone wiring of the detector base should be checked before the detector are installed in them The wiring should be checked for continuity and in the base and dielectric tests should be performed base includes a label for recording the zone address and type of detector installed This information is important to set the address of the detector that will later be plugged into the base and to verify the type required that location ON NOT NOT 3 TyPICAL WIRINg DIAgRAM fOR 2 WIRE LOOP 4A ENABLINg ThE TAMPER RESISTANT CAPABILITy DO NOT LOOP WIRE TERMINAL 1 OR 2 WIRE RUN TO PROVIDE OF CONNECTIONS LEVER TAB AT DOTTED LINE BY TOWARD CENTER OF BASE A OPTIONAL WIRING LEVER REMOvINg ThE DETECTOR hEAD fROM ThE BASE SMALL BLADED SCREWDRIVER TO PUSH LEVER IN DIRECTION OF ARROW 5 CONNECTION TO REMOTE ANNUNCIATOR TERMINAL WIRE WITH SPADE LUG fEATURE Do NOT use the tamper resistant capability if the XR2 or XR2B Re Tool will be used TAB AT DOTTED LINE BY TOWARD CENTER OF BASE Tamper Resistant Tab in the Detector Mounting Bracket can make the tamper resistant by making it necessary to use a small screwdriver or tool to detach the detector from the base make the detector tamper resistant use needle nose pliers to break the tab at the scribed line on the tamper resistant tab Figures 1 and 4A the location of this tab on the detector mounting bracket remove the detector from the base after it has been made tamper resistant the decorative ring by rotating it in either direction and pulling it away the base Then insert a small screwdriver into the notch as indicated Figure 4B and press the plastic lever toward the mounting surface before the detector counterclockwise for removal ANNUNCIATOR MODEL RA400Z the remote annunciator between terminals 1 and 3 using the spade terminal included The spade lug terminal is connected to the base termi as shown in Figure 5 is not acceptable for three stripped wires to be under the same wiring termi unless they are separated by a washer or a lug like the spade lug supplied the model RA400Z See Figure 5 for installation refer to insert for the Limitations of Fire Alarm Systems LIMITED WARRANTy Sensor warrants its enclosed smoke detector base to be free from defects in ma and workmanship under normal use and service for a period of three years from of manufacture System Sensor makes no other express warranty for this smoke base No agent representative dealer or employee of the Company has the au to increase or alter the obligations or limitations of this Warranty The Company of this Warranty shall be limited to the repair or replacement of any part of the detector base which is found to be defective in materials or workmanship under use and service during the three year period commencing with the date of manu After phoning System Sensor toll free number 800 SENSOR2 736 7672 for a Authorization number send defective units postage prepaid to System Sensor Department RA 3825 Ohio Avenue St Charles IL 60174 Please a note describing the malfunction and suspected cause of failure The Company not be obligated to repair or replace units which are found to be defective because damage unreasonable use modifications or alterations occurring after the date of In no case shall the Company be liable for any consequential or incidental for breach of this or any other Warranty expressed or implied whatsoever even the loss or damage is caused by the Company negligence or fault Some states do not the exclusion or limitation of incidental or consequential damages so the above or exclusion may not apply to you This Warranty gives you specific legal and you may also have other rights which vary from state to state System Sensor

Related Files