I Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 AND MAINTENANCE INSTRUCTIONS Plug in Detector Base inches 10.2cm 60mm and 70mm centers Ratings includes base and detector Range Current Nominal Surge at Max Rated Voltage 1.5mA Current Nominal Temperature Range to 32 VDC at 24 VDC at 24 VDC to applicable sensor Operating Temperature Range INSTALLINg thoroughly read the System Sensor manual System Smoke Detectors Guide which provides detailed information on detector spacing zoning wiring and special applications Copies of this manual are at no charge from System Sensor DESCRIPTION B501 is a plug in detector base intended for use in an intelligent system with terminals provided for power and and remote annunciator con The communication takes place over the power and lines TERMINALS Remote Annunciator Annunciator 1 TERMINAL LAyOUT PROOF INSTALLATION gUIDELINES SEE fIgURE 2 wiring must be installed in compliance with the National Electrical Code the local authority having jurisdiction Proper wire gauges should be The conductors used to connect the smoke detectors to control pan and accessory devices should be color coded to prevent wiring mistakes connections can prevent a system form responding properly in the of a fire signal wiring the wiring between interconnected detectors and modules is recommended that the wiring be no smaller than 18 gauge 1.0 square Wire sizes up to 12 gauge wire 2.5 square mm may be used with the For best system performance the power and loop wires should twisted pair or shielded cable installed in separate grounded conduit to the loop from extraneous electrical interference If a cable shield is pro the shield connection to and from the base must be continuous by us wire nuts crimping or soldering as appropriate for a reliable connection Connections are made by simply stripping about 3 of an inch of insula from the end of the wire use strip gauge molded in base sliding the end of the wire under the clamping plate and tightening the clamping screw Do not loop the wire under the clamping plate zone wiring of the detector base should be checked before the detector are installed in them The wiring should be checked for continuity po in the base and dielectric tests base contains a label to write the zone address and type of detector to installed at that location This information is used to set the address of the head that will later be plugged into the base and to verify the type for that location 2 TyPICAL WIRINg DIAgRAM fOR 2 WIRE LOOP DO NOT LOOP WIRE TERMINAL 1 OR 2 WIRE RUN TO PROVIDE OF CONNECTIONS A OPTIONAL WIRING fEATURE Do Not use the tamper resistant capability if the XR2 or XR2B Removal will be used This detector base also includes an optional tamperproof that when activated prevents removal of the detector without the use a tool activate this feature simply break off the tab on the detector base shown in 3A and install the detector To remove the detector from the base once tamperproof feature has been activated place a small bladed screwdriver the small hole on the side of the base and push the plastic lever away the detector head see Figure 3B This will allow the detector to be ro counterclockwise for removal tamperproof feature may be defeated by breaking and removing the plas lever from the base however this prevents ever using the feature again ANNUNCIATOR RA400 remote annunciator is connected between terminals 1 and 3 using the lug terminal packed with the remote annunciator The spade lug termi is connected to the base terminal as shown in Figure 4 is not acceptable to have three stripped wires under the same wiring termi unless they are separated by a washer or equivalent means The spade lug with the model RA400 is considered an equivalent means See Figure for proper installation 3A ACTIvATINg TAMPERPROOf fEATURE LEVER TAB AT DOTTED LINE BY TOWARD CENTER OF BASE TO PRESS PLASTIC LEVER DIRECTION OF ARROW TOWARD CENTER OF BASE 3B REMOvINg DETECTOR hEAD fROM BASE TO PRESS PLASTIC LEVER DIRECTION OF ARROW 4 CONNECTION TO REMOTE ANNUNCIATOR TERMINAL WIRE WITH SPADE LUG refer to insert for the Limitations of Fire Alarm Systems LIMITED WARRANTy Sensor warrants its enclosed smoke detector base to be free from defects in ma and workmanship under normal use and service for a period of three years from of manufacture System Sensor makes no other express warranty for this smoke base No agent representative dealer or employee of the Company has the au to increase or alter the obligations or limitations of this Warranty The Company of this Warranty shall be limited to the repair or replacement of any part of the detector base which is found to be defective in materials or workmanship under use and service during the three year period commencing with the date of manu After phoning System Sensor toll free number 800 SENSOR2 736 7672 for a Authorization number send defective units postage prepaid to System Sensor Department RA 3825 Ohio Avenue St Charles IL 60174 Please a note describing the malfunction and suspected cause of failure The Company not be obligated to repair or replace units which are found to be defective because damage unreasonable use modifications or alterations occurring after the date of In no case shall the Company be liable for any consequential or incidental for breach of this or any other Warranty expressed or implied whatsoever even the loss or damage is caused by the Company negligence or fault Some states do not the exclusion or limitation of incidental or consequential damages so the above or exclusion may not apply to you This Warranty gives you specific legal and you may also have other rights which vary from state to state System Sensor