System Sensor B501B-FTX
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-b501b-ftx-2468379015.pdf |
---|---|
Type | |
Size | 1.00 MB |
Downloads |
Text Preview
INSTALLATION AND MAINTENANCE INSTRUCTIONS Detector Base use with the Filtrex Smoke Detector Ratings Installing thoroughly read the system wiring and installation and manual I56 407 Guide for Proper Use of Smoke Detectors which on detector spacing placement zoning and special Copies of these manuals are available at no The detector used with these bases must tested and maintained regularly following NFPA 72 The detectors should be cleaned at least and 4 inch square boxes with or without a plaster Guidelines and accessory devices should be color coded to the likelihood of wiring errors Improper connec gauge 1.0 square mm However wire sizes up to 12 3.3 square mm can be used with the base The loop resistance Consult the control panel specifica for the total loop resistance allowed before wiring refer to insert for the Limitations of Fire Alarm Systems Limited Warranty alter the obligations or limitations of this Warranty The Company period commencing with the date of manufacture After phoning number send defective units postage prepaid to System Repair Department RA 3825 Ohio Avenue St replace units which are found to be defective because of damage use modifications or alterations occurring after the date manufacture In no case shall the Company be liable for any conse or limitation of incidental or consequential damages so the above or exclusion may not apply to you This Warranty gives you 2 Wiring diagram 1 Mounting the base to an electrical box 4 S 3A Activating the tamper resist feature 3B Removing the detector head from the LEVER TAB AT LINE BY TOWARD OF BASE SMALL BLADED TO PLASTIC LEVER DIRECTION OF Instructions the clamping plate and tighten the clamping plate the remote annunciator RA line to terminal 3 see 2 Wire the communication lines in and out the auxiliary power supply positive line to the Wire the auxiliary power supply return to the the zone wiring of all bases in the system before detector heads This includes checking the wir label is affixed to the base for recording the zone and type of detector being installed at the base This information is useful for setting the detec head address and for verification of the sensor type Feature activate this feature break the tab from the detector remove the detector from the base once the tamper feature has been activated insert a small bladed plastic lever away from the detector head see Figure