System Sensor L-Series Strobes and Horn Strobes - Ceiling
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-l-series-strobes-and-horn-strobes-ceiling-3972106854.pdf |
---|---|
Type | |
Size | 3.62 MB |
Downloads |
Text Preview
Indoor Selectable Strobes and Strobes for Applications Sensor L Series audible visible notification are rich with features guaranteed to cut times and maximize profits with lower draw and modern aesthetics Plug in design with minimal intrusion into the back box Tamper resistant construction Automatic selection of 12 or 24 volt operation 15 and 30 candela Field selectable candela settings on ceiling units 30 75 95 115 150 and 177 Horn rated at 88 dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Compatible with MDL3 sync module Listed for ceiling mounting only Listings approved except ALERT models System Sensor L Series offers the most versatile and line of horns strobes and horn strobes in the industry lower current draws and modern aesthetics With white and red housings wall and ceiling mounting options System Sensor can meet virtually any application requirement entire L Series product line of ceiling mount strobes and horn include a variety of features that increase their application while simplifying installation All devices feature a plug in with minimal intrusion into the back box making installations and foolproof while virtually eliminating costly and time ground faults Mounting plate shorting spring feature checks wiring continuity device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices further simplify installation the L Series utilizes a universal plate so installers can mount them to a wide array of back With an onboard shorting spring installers can test wiring before the device is installed can also easily adapt devices to a suit a wide range of requirements using field selectable candela settings selection of 12 or 24 volt operation and a rotary switch horn tones with two volume selections 12 01 2017 Page 3 Specifications Specifications ceiling mount strobes and horn strobes shall mount to a standard 4 4 1 back box 4 inch octagon back box or double back box Two wire products shall also mount to a single gang 2 4 17 back box A universal mounting plate shall be used mounting ceiling and wall products The notification appliance circuit wiring shall terminate at the universal mounting plate Also L Series when used with the Sync Module accessory shall be powered from a non coded notification appliance circuit output shall operate on a nominal 12 or 24 volts When used with the Sync Module 12 volt rated notification appliance circuit outputs operate between 8.5 and 17.5 volts 24 volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts Indoor products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full wave rectified unfiltered power supply strobes and horn strobes shall have field selectable candela settings including 15 30 75 95 115 150 and 177 strobe shall be a System Sensor L Series Model listed to UL 1971 and shall be approved for fire protective service The strobe be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible appliances flashing at 1 Hz over the strobe entire operating voltage range The strobe light shall consist of a xenon flash tube and lens reflector system Strobe Combination horn strobe shall be a System Sensor L Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective The horn strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act for visible signaling appliances flashing at 1 Hz over the strobe entire operating voltage range The strobe light shall consist a xenon flash tube and associated lens reflector system The horn shall have two audibility options and an option to switch between a three pattern and a non temporal continuous pattern These options are set by a multiple position switch The horn on horn strobe shall operate on a coded or non coded power supply Module module shall be a System Sensor Sync model MDL3 listed to UL 464 and shall be approved for fire protective service The module synchronize L Series strobes at 1 Hz and horns at temporal three Also while operating the strobes the module shall silence the horns horn strobe models over a single pair of wires The module shall mount to a 4 11 4 11 2 1 back box The module shall also two Style Y class B circuits or one Style Z class A circuit The module shall synchronize multiple zones Daisy chaining two or more modules together will synchronize all the zones they control The module shall not operate on a coded power supply Specifications Operating Temperature Range Flash Rate Voltage Voltage Range2 Voltage Range MDL3 Terminal Wire Gauge Dimensions including lens Surface Mount Back Box Skirt Dimensions SBBCWL Full Wave Rectified FWR voltage is a non regulated time varying power source that is used on some power supply and panel outputs P S PC and SC products will operate at 12 V nominal only for 15 and 30 cd to 120 0 to 49 to 93 non condensing flash per second 12 VDC or regulated 24 DC FWR1 to 17.5 V 12 V nominal or 16 to 33 V 24 V nominal to 17.5V 12 V nominal or 16.5 to 33 V 24V nominal to 18 AWG diameter 2.5 high 173 mm diameter 64 mm high diameter x 3.4 high 175 mm diameter x 86 mm high 12 01 2017 Page 2 Current Draw Data Max Strobe Current Draw mA RMS Volts Volts Max Horn Current Draw mA RMS Pattern KHz Temporal KHz Temporal KHz Non Temporal High KHz Non Temporal Low KHz Coded Volts 16 Volts Max Current Draw mA RMS Ceiling Horn Strobe Candela Range 15 cd Input High Low High Low Temporal High Temporal Low Non Temporal High Non Temporal Low Input High Low High Low Temporal High Temporal Low Non Temporal High Non Temporal Low Volts Volts Volts Strobe Tones and Sound Output Data Strobe Output dBA Sound Pattern KHz Temporal KHz Temporal KHz Non Temporal KHz Non Temporal 12 01 2017 Page 3 Dimensions diam mm 62.7 mm 34.8 mm diam mm mm Horn Strobes Surface Mount Back Box Ceiling Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes Ceiling Surface Mount Back Box Ordering Information Horn Strobes Horn St