System Sensor M500S

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-m500s-8651742930.pdf
Type PDF
Size 1.78 MB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Supervised Control Module Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 Operating Voltage Current Draw Current NAC Line Loss Supply Voltage between Terminals T3 and T4 NAC Current Ratings Range NAC Speakers to 32 VDC LED On max 1 communication every 5 seconds 47k EOL resistor 485 max Communicating NAC Shorted VDC 24VDC V RMS 50 W class B wiring system the current rating is 3A For class A wiring system the current rating is 2A to 120 0 to 49 to 93 Non condensing H 4 W 11 4 D Mounts to a 4 square by 21 8 deep box Electrical Box CB500 Barrier 2A MODULE MOUNTINg fIgURE 2B BARRIER INSTALLINg information is included as a quick reference installation guide Refer to control panel installation manual for detailed system information If the will be installed in an existing operational system inform the opera and local authority that the system will be temporarily out of service Dis power to the control panel before installing the modules This manual should be left with the owner user of this equipment DESCRIpTION Supervised Control Modules are intended for use in intelligent two systems where the individual address of each module is selected using built in rotary decade switches This module is used to switch an external supply which can be a DC power supply or an audio amplifier up 80 VRMS to notification appliances It also supervises the wiring to the loads and reports their status to the panel as NORMAL OPEN SHORT CIRCUIT The M500S has two pairs of output termination points for fault tolerant wiring and a panel controlled LED indicator This can be used to replace an M500C module that has been configured for wiring operation REqUIREMENTS ensure proper operation these modules shall be connected to listed com system control panels only 1 CONTROLS AND INDICATORS LIMITED wARRANTy relay switch contacts are shipped in the standby state open state but may have transferred to the activated closed state during shipping To ensure that switch contacts are in their correct state modules must be made to communicate with the panel before connecting circuits controlled by the module Sensor warrants its enclosed module to be free from defects in materials and under normal use and service for a period of three years from date of System Sensor makes no other express warranty for this module No agent dealer or employee of the Company has the authority to increase or the obligations or limitations of this Warranty The Company obligation of this shall be limited to the repair or replacement of any part of the module which found to be defective in materials or workmanship under normal use and service the three year period commencing with the date of manufacture After phoning Sensor toll free number 800 SENSOR2 736 7672 for a Return Authorization send defective units postage prepaid to System Sensor Repair Department RA 3825 Ohio Avenue St Charles IL 60174 Please include a note describing malfunction and suspected cause of failure The Company shall not be obligated to or replace units which are found to be defective because of damage unreasonable modifications or alterations occurring after the date of manufacture In no case shall Company be liable for any consequential or incidental damages for breach of this any other Warranty expressed or implied whatsoever even if the loss or damage is by the Company negligence or fault Some states do not allow the exclusion or of incidental or consequential damages so the above limitation or exclusion not apply to you This Warranty gives you specific legal rights and you may also other rights which vary from state to state System Sensor All wiring must conform to applicable local codes ordinances and reg When using control modules in nonpower limited applications the Sensor CB500 Module Barrier must be used to meet UL requirements the separation of power limited and nonpower limited terminals and wir The barrier must be inserted into a 4 junction box and the module must be placed into the barrier and attached to the junction Figure 2A The power limited wiring must be placed into the isolated of the module barrier Figure 2B Install module wiring in accordance with the job drawings and appropri wiring diagrams the address on the module per job drawings Secure module to electrical box supplied by installer as shown in 2A M500S mounts directly to 4 inch square electrical boxes see Figure 2A box must have a minimum depth of 21 8 inches Surface mounted electri boxes SMB500 are available from System Sensor 3 TypICAL NOTIfICATION AppLIANCE CIRCUIT CONfIgURATION NfpA STyLE y 5 TypICAL wIRINg fOR SpEAkER SUpERvISION AND SwITChINg NfpA STyLE y CIRCUIT WIRING MUST BE TWISTED PAIR AS A MINIMUM SEE PANEL INSTALLATION MANUAL FOR DETAILED INFORMATION 4 TypICAL fAULT TOLERANT NOTIfICATION AppLIANCE CIRCUIT CONfIgURATION NfpA STyLE Z ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE VDC CIRCUIT NOT LOOP WIRE ON TERMINALS 10 11 WIRE RUN TO PROVIDE SUPERVISION CONNECTIONS MODULES TO LISTED CONTROL PANELS ONLY 6 TypICAL fAULT TOLERANT wIRINg fOR SpEAkER SUpERvISION AND SwITChINg NfpA STyLE Z CIRCUIT WIRING MUST BE TWISTED PAIR AS A MINIMUM SEE PANEL INSTALLATION MANUAL FOR DETAILED INFORMATION MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY NOT LOOP WIRE ON TERMINALS 10 11 BREAK WIRE TO PROVIDE SUPERVISION OF CONNECTIONS VDC CIRCUIT MODULES TO COMPATIBLE PANELS ONLY VDC POWER SUPPLY REGULATED LIMITED PER NFPA 70 FOR FIRE PROTECTION BATTERY BACKUP POLARITIES ARE IN ALARM EOL LISTED EOL RELAY ENERGIZED VDC COIL EOLR 1 NEXT CONTROL MODULE OR END OF LINE ONE RELAY REQUIRED FOR EACH SOME CONTROL PANELS HAVE RELAY IN AND DO NOT REQUIRE EXTERNAL REFER TO PANEL MANUAL OR LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED WIRING SHOWN IS SUPERVISED POWER LIMITED NEXT ANY FAULT IN THE POWER SUPPLY IS TO THAT ZONE AND DOES NOT IN A FAULT IN A SEPARATE ZONE VDC POWER SUPPLY REGULATED POWER PER NFPA 70 LISTED FIRE PROTECTION WITH BACKUP POLARITIES ARE IN ALARM RESISTOR INTERNAL AT 9 LISTED EOL SHOWN VDC COIL NEXT CONTROL MODULE OR RELAY ONE RELAY FOR EACH CIRCUIT CONTROL PANELS HAVE BUILT IN AND DO NOT EXTERNAL WIRING TO PANEL MANUAL OR LINE CIRCUIT SLC VDC MAX TWISTED PAIR RECOMMENDED WIRING SHOWN IS SUPERVISED POWER LIMITED ANY FAULT IN THE POWER SUPPLY LIMITED TO THAT ZONE AND DOES NOT IN A FAULT IN A SEPARATE ZONE CIRCUIT NOT LOOP WIRE AROUND TERMINALS 11 BREAK WIRE TO ENSURE OF CONNECTIONS AMPLIFIER 70.7 Vrms MAX MUST PROVIDE WIRING PER NFPA EOL POLARITIES ARE IN ALARM MUST BE PER NFPA MODULES TO LISTED COMPATIBLE PANELS ONLY PANEL OR DEVICE LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED NEXT NEXT CONTROL MODULE MODULE MUST RETURN FOR SUPERVISION MUST BE LISTED FOR FIRE REFER TO THE RELAY CONTACT TABLE FOR MAXIMUM LOA

Related Files