Gamewell-FCI 1151 Ionization Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-1151-ionization-detector-4103269857.pdf |
---|---|
Type | |
Size | 616.45 KB |
Downloads |
Text Preview
DESCRIPTION System Sensor 1151 low profile ionization type smoke are specifically designed to meet the performance of fire detection alarm systems The 1151 ion detector uses a state of the art dual unipolar sensing The detector is designed to provide open area de and when installed in a two wire base is compatible FCI fire alarm control panels The detector operation sensitivity can be tested in place 1151 detector is of plug in construction and plugs into same base as the System Sensor 2151photoelectronic detector making both models interchangeable Bases available for two wire four wire 120 VAC four wire op and also with an audible sounder visible LEDs on each detector flash every ten seconds that power is being applied to the detector The light steadily when the detector is in alarm A remote annunciator is available as an optional accessory 1151 detector is Listed for use inside ducts up to a ve of 500 FPM testing is performed by placing a test magnet the cover The LED on the detector should light 30 seconds metering of detector sensitivity may be performed the aid of a voltmeter and Test Kit MOD 400R SENSOR PROFILE IONIZATION SMOKE DETECTOR Unique Dual Unipolar Sensor Exceptional Stability Low Profile Construction Easy plug in of the Head to Base Tamper resistant Feature Test Switch View Angle Of Alarm LEDs Compatible with FCI Control Panels Audible Sounder Base Optional Field Metering of Detector Sensitivity Removable Insect Screen and Cover Field Cleaning Screening mm openings voltage current temperature humidity velocity ft nominal 32 VDC peak uA max avg to 120o F 0 to 49o C to 93 non condensing feet per minute maximum flame retardant plastic inches 10.2 cm inches 4.2 cm oz 104 g are provided for information only are not intended to be used for installation purposes and are believed to be accurate However no responsibility is assumed by Fire Control Inc for their use Specifications subject to change without notice 2003 All Rights Reserved Southwest Park Westwood MA 02090 USA TEL 781 471 3000 FAX 781 471 3099 ISO 9001 Certified Company 1.1 On a 4 inch square box with or without plaster Minimum depth 1.5 inches On a 3.5 inch octagonal box Minimum depth inches the detector into the detector base Turn the de clockwise until the detector locks into place use the tamper proof feature break the smaller tab the scribed line in the tamper proof tab located on the mounting bracket Install the detector To re the detector from the base when using the tam feature blade of a small into the hole on the side of the base and the plastic lever away from the detector head This allow the detector to be rotated counterclockwise removal NOTE The decorative ring must be re in order to remove the head when using the tam feature tamper proof feature may be defeated perma by breaking the plastic lever off the base The number of two wire smoke detectors can be accommodated per zone varies with dif control panels Consult the control panel in manual to determine the capacity to NFPA72 Chapter 5 3 Sensing Fire for spacing location of detectors and other may be tested in the following ways Place a test magnet against the detector directed in the installation instructions detector should go into alarm within seconds Field metering of detector sensitivity may be with the aid of a voltmeter and Test MOD 400R For the complete procedure to the Installation and Maintenance furnished with each detector programs should be adapted to the individ environment We recommend at least an annual of the unit The detector screen and cover as can be removed revealing the sensing cham A vacuum cleaner can be used to remove dust from screen cover and sensing chamber For the com procedure refer to the Installation and Mainte Instructions furnished with each detector AND TECHNICAL INFORMATION Detector Two wire A C four wire 24 VDC operation A C Supv Base four wire 120 VAC operation four wire with audible sounder Alarm Indicator of Line Relay 24 VDC Kit 400R B of 2