Gamewell-FCI 2151 Photo Smoke Detector Low Profile

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-2151-photo-smoke-detector-low-profile-0127963854.pdf
Type PDF
Size 634.48 KB
Downloads

Text Preview

2151 Sensor Profile Photoelectronic Built with a low profile construction Offers an easy plug in of the head to base Designed with a tamper resistant feature a Test Switch Shows a 360 view angle of the alarm LEDs Compatible with Gamewell FCI control panels Uses an audible sounder base optional Supports the field metering of detector sensitivity Provides a removable insect screen and cover for field Has an insect resistant screening 020 508 mm 205 94 E System Sensor 2151 low profile photoelectronic detector is specifically designed to meet the perfor requirements of the fire detection alarm systems 2151 detector uses a state of the art optical sensing and is designed so that if the LED fails it will not an alarm The detector is designed to provide open detection and when installed in a two wire base is with the Gamewell FCI fire alarm control pan The detector operation and sensitivity can be tested place 2151 detector is designed with plug in construction plugs into the same base as the 1151 ionization detector making both models interchangeable are available for the following types of operation visible LEDs on each detector flash approximately ten seconds indicating that the power is being to the detector The LEDs light steadily when the is in alarm A remote LED annunciator is available an optional accessory 2151 is UL Listed for mounting inside ducts up to a of 3,000 FPM perform functional testing place a test magnet against cover The LED on the detector should light within 30 perform the field metering of the detector sensitivity use voltmeter and Test Kit Part Number MOD 400R 2151 can be mounted on the following On a 4 inch square box with or without a plaster ring 120 VAC four wire an audible sounder depth 1.5 inches On a 3.5 inch octagonal box Minimum depth 1.5inches install the detector do the following Place the detector into the detector base Turn the detector clockwise until the detector locks place To use the tamper proof feature break the smaller tab the scribed line in the tamper proof tab located on detector mounting bracket the detector is a registered trademark of Underwriters Laboratories Inc GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 Honeywell International Inc All rights reserved Rev C page 1 of 2 ft nominal 35 VDC 24 VDC nominal uA maximum Voltage Current Temperature 32 to 120 F 0 to 49 C humidity velocity 93 relative humidity feet per minute maximum flame retardant plastic inches 15.5 cm base inches 4.2 cm oz 104 g Information Number Description detector Two wire four wire 24 VDC operation Form A C four wire 120 VAC operation Form C Supv four wire with audible sounder alarm indicator relay 24 VDC Form B Test Kit Continued you use the tamper proof feature to remove the from the base insert the blade of a small into the hole on the side of the base Push the plastic lever away from the detector head This action allows the detector to be rotated counter so that you can remove it To remove the head when using the tamper proof remove the decorative ring tamper proof feature may be defeated permanently by the plastic lever from the base The number of two wire smoke detectors which can accommodated per zone varies with the different con panels Consult the control panel instruction manual to the capacity information on the spacing the location of detectors other guidelines refer to NFPA 72 Chapter 5 3 Sensing Fire Detectors may be tested in the following ways Place a test magnet against the detector as directed in installation instructions The detector should go into within 30 seconds To perform field metering of detector sensitivity use a and Test Kit Part Number MOD 400R the complete procedure refer to the Installation and instructions furnished with each detector programs should be adapted to the individual in compliance with NFPA Standard 72 recommends at least an annual cleaning of unit The detector screen and cover assembly can be revealing the sensing chamber Use a vacuum to remove dust from the screen the cover and the chamber For the complete procedure refer to the and Maintenance instructions furnished with detector Rev C page 2 of 2 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118

Related Files