Gamewell-FCI 301PL SERIES Photoelectric Detector

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-301pl-series-photoelectric-detector-1074625938.pdf
Type PDF
Size 604.40 KB
Downloads

Text Preview

DESCRIPTION FCI 301PL series low profile photoelectronic smoke is specifically designed to meet the performance re of fire detection alarm systems The 301PL de uses a state of the art optical sensing chamber and is so that LED failure will not cause an alarm The de is designed to provide open area detection and when in a two wire base is compatible with FCI fire control panels The detector operation and sensitivity be tested in place 301PL detector is of plug in construction and plugs the same base as the FCI 301IL series ionization smoke making both models interchangeable Bases are for two wire four wire and 120 VAC four wire op and also with an audible sounder visible LEDs on each detector flash every ten seconds that power is being applied to the detector The light steadily when the detector is in alarm A remote annunciator is available as an optional accessory 301PL is UL Listed for mounting inside ducts up to a of 3,000 FPM testing is performed by placing a test magnet the cover The LED on the detector should light 30 seconds metering of detector sensitivity may be performed the aid of a voltmeter and Test Kit Part No 119 9010N Std 268 1913 SERIES PROFILE PHOTOELECTRONIC SMOKE DETECTOR Low Profile Construction Easy Plug in of the Head to Base Tamper resistant Feature Test Switch 360o View Angle of Alarm LEDs Compatible with FCI Control Panels Audible Sounder Base Optional Field Metering of Detector Sensitivity Removable Insect Screen and Cover Field Cleaning Insect resistant Screening 020 508 Openings SPECIFICATIONS voltage current temperature humidity velocity ft nominal 35 VDC 24 VDC nominal uA maximum to 120o F 0o to 49o C 93 relative humidity feet per minute maximum flame retardant plastic inches 15.5 cm flanged base inches 4.2 cm oz 104 g are provided for information only are not intended to be used for installation purposes and are believed to be accurate However no responsibility is assumed Fire Control Instruments Inc for their use Specifications subject to change without notice 1997 All Rights Reserved 2nd Ave Waltham MA 02451 1133 USA TEL 781 487 0088 FAX 781 370 4132 1.4 CONTROL INSTRUMENTS Inc On a 4 inch square box with or without ring Minimum depth 1.5 inches On a 3.5 inch octagonal box Minimum depth inches the detector into the detector base Turn the de clockwise until the detector locks into place use the tamper proof feature break the smaller tab the scribed line in the tamper proof tab located on the mounting bracket Install the detector To re the detector from the base when using the tam feature blade of a small into the hole on the side of the base and the plastic lever away from the detector head This allow the detector to be rotated counterclockwise removal NOTE The decorative ring must be re in order to remove the head when using the tam feature tamper proof feature may be defeated perma by breaking the plastic lever off the base The number of two wire smoke detectors can be accommodated per zone varies with dif control panels Consult the control panel in manual to determine the capacity to NFPA 72 Chapter 5 3 Sensing Fire for spacing location of detectors and other may be tested in the following ways Place a test magnet against the detector as in the installation instructions The de should go into alarm within 30 Field metering of detector sensitivity may be with the aid of a voltmeter and Test P N 119 9010N the complete procedure refer to the Installation Maintenance instructions furnished with each de programs should be adapted to the individ environment in conformance with NFPA Standard We recommend at least an annual cleaning of the The detector screen and cover assembly can be re revealing the sensing chamber A vacuum can be used to remove dust from the screen and sensing chamber For the complete proce refer to the Installation and Maintenance instruc furnished with each detector AND TECHNICAL INFORMATION No A C Detector Two wire four wire 24 VDC operation Form A C Supv Base four wire 120 VAC operation four wire with audible sounder Alarm Indicator of Line Relay 24 VDC Kit B of 2

Related Files