Gamewell-FCI 411UDAC Digital Alarm Communicator Transmitter
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-411udac-digital-alarm-communicator-transmitter-8017459632.pdf |
---|---|
Type | |
Size | 645.04 KB |
Downloads |
Text Preview
Description Gamewell FCI 411UDAC is a compact multi faceted Fire Alarm Communicator designed for use a variety of fire and non fire applications It provides channels inputs that accept signals from the follow devices waterflow devices and four wire smoke detectors other normally open contact devices pull stations 411UDAC is a cost effective solution used with appli that require an existing or new Fire Alarm Control Security Panel that can transmit system status to an off monitoring facility for Central or Remote Station com to its flexible programming options the 411UDAC is for use as a stand alone unit to monitor the following sprinkler systems used for waterflow and supervisory water level gas detection loss of air flow processes normally open contact devices uses fifteen selectable transmission formats including Ademco Contact ID This large number of formats the 411UDAC compatibility with all Digital Alarm Receivers DACR You can program on using a hand held programmer PRO 411 or you can remotely using an optional PK CD Upload Down software package The PK CD Upload Download software also permits interrogation and revision from a remote site Line Connections are two modular phone connections provided on the door of the 411UDAC They provide connections for separate telephone lines using the standard RJ31X Both telephone lines are constantly supervised for voltage and current If one phone line goes into and the remaining phone line remains operational a is sent to the central or remote station via the opera phone line Alarm Alarm Transmitter Complies with Industry first UL recognized run prevention features Provides one Style Y Class B Notification Appliance Circuit NAC Support 1.0 Amp of notification appliance power Has a coded temporal notification appliance bell sig circuit Contains four supervised monitoring channels inputs Normally open contacts Supervisory auto resettable Three fixed Style B Class B One Style A Class A or style B Class B may be individually programmed for stand alone or programmed when monitoring a host panel for the following applications Two and four wire smoke detectors Inputs 1 and 3 Pull Station Supervisory Process Monitoring Process Monitoring auto resettable Host Panel Trouble slave mode Waterflow silenceable and non silenceable seven LEDs with six LEDs visible through AC Power Supervisory Earth fault not visible with door closed System Trouble Communication Fail System Alarm Battery Trouble 12 VDC operation Capable of 60 hours standby Offers dual telephone lines Dual telephone line voltage detect Alternating phone lines 24 hour test messages programmable Vol VI GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Rev B page 1 of 4 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved Formats 4 1 Ademco Express Standard DTMF 1400 2300 ACK 4 2 Ademco Express Standard DTMF 1400 2300 ACK 3 1 Standard 1800 Hz Carrier 2300 Hz ACK 3 1 Expanded 1800 Hz Carrier 2300 Hz ACK 3 1 Standard 1900 Hz Carrier 1400 Hz ACK 3 1 Expanded 1900 Hz Carrier 1400 Hz ACK 4 1 Standard 1800 Hz Carrier 2300 Hz ACK 4 1 Expanded 1800 Hz Carrier 2300 Hz ACK 4 1 Standard 1900 Hz Carrier 1400 Hz ACK 4 1 Expanded 1900 Hz Carrier 1400 Hz ACK 4 2 Standard 1800 Hz Carrier 2300 Hz ACK 4 2 Expanded 1800 Hz Carrier 2300 Hz ACK 4 2 Standard 1900 Hz Carrier 1400 Hz ACK 4 2 Expanded 1900 Hz Carrier 1400 Hz ACK Contact ID DTMF 1400 2300 ACK Future use program the 411UDAC use an optional digital program unit with a keypad model PRO unit can be used to troubleshoot and to access the various of operation Off site programming can be accom with the optional PK CD programming software PKCD enables a user to program the 411UDAC off via the public switched telephone network using any computer with the following Windows applica Windows 3.1 or higher Windows 95 and a 1200 baud Hayes compatible cabinet is red and measures 14.5 36.83 cm high x 31.75 cm wide and 2.875 7.303 cm deep It pro space for up to two 7 A H batteries order batteries An optional dress panel DP 2 which mounts the cabinet is available The dress panel restricts to the system wiring but allows access to the mem switch panel Assembly transformer is shipped in the same carton as the cabi and main circuit board but not mounted in the cabinet transformer should be installed before the cabinet is to the wall Relay optional Form C relays 411RK are available for on the 411UDAC main circuit board The relays programmable for activation on fire alarm host panel fire supervisory process monitoring total commu failure and DACT trouble Relay contact rating amps 30 VDC resistive Continued Complies with the new long distance Carrier Access CAC accepting 20 digit central station and ser terminal telephone numbers Fully programmed transmittal codes for fire and non fire process monitoring applications user selectable restoral methods Capable of transmitting the following DACT information addition to transmitting vital system status of the host panel DACT troubles Telephone line 1 and 2 voltage fault Primary or secondary Central Station communication fault System off normal 24 hour normal test and 24 hour abnormal test 15 popular communication formats including widely used Ademco Contact ID format ensuring with virtually all DACRs Local piezo sounder that signals a separate and a sound for the various conditions Offers the following Display options Acknowledge System Silence Reset switches Auto Silence Alarm Verification Trouble Reminder with 24 hour resound Signal Silence Inhibit Real time clock Optional two Form C relays 411 RK fully programma Total Communication Trouble to activate for the following conditions Fire alarm Host Control Panel Trouble Process Monitoring with auto resettable Process Monitoring Fire Supervisory latching and auto resettable DACT trouble factory default for relay Optional PK CD Remote Upload Download Kit and DP Dress Panel Power TB3 Size VAC 60 Hz 0.3 amps 14 AWG 2.00 mm 600 V insulation lead acid only J3 Charging Circuit normal flat charge V 0.6 amps Charger Capacity 14 AH battery TB2 terminals 1 through 10 Programmable channels 1 through 4 Class 3 Power Limited circuitry Fully supervised monitored for opens shorts and earth Operating Voltage 12.0 VDC Resistor for Each Channel 3 100 mV maximum ohms 1 2 watt 27070 UL Listed B Class B two wire detector input B Class B or Style D A two wire smoke or waterflow input Rev B page 2 of 4 Clintonville Road Northford CT 06472 1653 USA Tel 203 484 7161 Fax 203 484 7118 Information Number Description Four channel dual line stand alone or slave Alarm Communicator Includes housing and programming instructions PRO 411 below hand held DACT pro for local programming or PK below Windows program software for remote programming and diagnostics dress panel hand held DACT programmer can be used to troubleshoot and pro the 411UDAC as well as access the modes of operation upload download programming soft kit The PK CD enables a user to pro the 411UDAC off site via the public telephone network usi