Gamewell-FCI 7100 00-0448

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-7100-00-0448-0523871694.pdf
Type PDF
Size 573.53 KB
Downloads

Text Preview

OPERATING INSTRUCTIONS SERIES FIRE ALARM CONTROL PANEL SYSTEM MUST BE TESTED REGULARLY IN ACCORDANCE WITH THE APPLICABLE FIRE CODES CONSULT YOUR MARSHAL IN CASE OF DOUBT green POWER ON light is lit The time is displayed on the panel display All other lights and sounding devices are off CONDITION CONDITION red light is flashing the display which identifies the source of alarm is flashing the alarm signals are sounding are flashing and the panel sounding device is PROPER EMERGENCY PROCEDURES FOR NOTIFYING THE FIRE DEPT EVACUATING THE BUILDING ETC To acknowledge the alarm condition the key activating the control cluster and press the ACKNOWLEDGE switch once This will cause the alarm light and display to stay on steadily and silence the panel sounding device MULTIPLE ALARM INDICATIONS MUST BE ACKNOWLEDGED INDIVIDUALLY ALARMS WILL SCROLL THE FIRST WILL BE INDICATED ON THE DISPLAY When told by an authorized person there is no hazard and it is safe to do so you may silence the audible alarm signals the SILENCE switch once This will light the yellow TROUBLE and SILENCED The 1 SILENCED and 2 SILENCED lights may also light After an alarm condition immediately notify Authorized Personnel When authorized to do so the system can be reset by pressing the RESET LAMP TEST switch Hold this switch for at least four 4 seconds CONDITION light is flashing The panel audible signal will sound and the display will indicate a supervisory message NOTIFY AUTHORIZED PERSONNEL IMMEDIATELY When told by an authorized person it is safe to do so then the key activating the control cluster and press the ACKNOWLEDGE switch This will cause the light and display to stay on steady and will silence the panel audible signal When the cause of the condition has been corrected the system can be reset by pressing the RESET LAMP switch Hold this switch down for at least four 4 seconds Note that all initiating devices must be restored to first or the system will not reset CONDITION TROUBLE light is lit Depending on the trouble condition s other fault lights may also be lit The panel device will sound and the display will flash a description of the fault NOTIFY AUTHORIZED PERSONNEL IMMEDIATELY DO NOT LEAVE THE PANEL IN A TROUBLE CONDITION THE FIRE MAY NOT WORK PROPERLY LIVES MAY BE LOST IN A FIRE IF THE FIRE ALARM SYSTEM IS NOT OPERATING IT MAY BE UNABLE TO PERFORM ITS INTENDED FUNCTION To acknowledge the trouble condition and silence the panel sounding device the key activating the control cluster and press the switch on the display or System Control Unit this switch will also cause the display to stay on steadily MULTIPLE TROUBLE INDICATIONS MUST BE ACKNOWLEDGED INDIVIDUALLY The yellow TROUBLE light and the display will remain lit until the trouble condition s has been corrected When the trouble condition s has been corrected the system will return to the normal condition REPLACEMENT There are no replaceable fuses in this panel THIS EQUIPMENT IS TO BE SERVICED ONLY BY QUALIFIED PERSONNEL FOR SERVICE CALL QUALIFIED SERVICE PERSONNEL MUST DISCONNECT THE MAIN AC PRIOR TO SERVICING OR ELECTRIC MAY RESULT THE AC DISCONNECT IS LOCATED AT THESE INSTRUCTIONS ADJACENT TO THE CONTROL SYSTEM IN A FRAMED ENCLOSURE Copyright 1999 Fire Control Instruments Inc All rights reserved 1.0

Related Files