Gamewell-FCI 7200 Series Fire Alarm Control Panel

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-7200-series-fire-alarm-control-panel-4018735269.pdf
Type PDF
Size 677.74 KB
Downloads

Text Preview

DESCRIPTION Fire Control Instruments 7200 Series Analog H a r d w i r e i r e A l a r m C o n t r o l C I N E T s and designed for commercial indus proprietary central station and institutional applica The 7200 Series may be configured as an point identified system where individ identification of initiating devices and control points are a conventional hard wired zone identified system combination of both It meets the requirements of NFPA 72 and is suitable for releasing device service 7200 Series is field programmable to perform a wide of functions Inherently power limited it can accom 15 units of one type with a maximum total combina of 30 units Units are available in a wide range of around multiprocessors that provide and control system functions the 7200 Series has a powerful software that affords true processing of all sys components The system can accommodate module at either a central location or up to fifteen 15 re locations via the FCINET communications to provide system features FCI Listed Integrated Sensitivity Testing LIST pro meets all NFPA 72 requirements for testing and moni of sensor sensitivity 7200 Series control has been tested for extraordinary conditions with 6,000 volt transient immunity cir FEATURES Distributed Fire Alarm Voice System Operation Alpha numeric Display Integral Sensitivity Testing meets 72 Testing Requirements Drift Compensation Overcomes Effects Aging or Environment on Sensor and Dirty Sensor Indica Day Night Sensor Sensitivity Setting Class A Style 6 7 or Class B Style 4 Line Circuits Analog Sensor Alarm Verification Programmable and Power Relays Technology Power Supply with FireVac Emergency Evacuation System Releasing Device Unit with Abort Timer SERIES ALARM CONTROL UL Listed to Standard 864 Category UOJZ FCI Communication Network Signaling Line Circuits Power Limited per UL 864 ADAC Degrade Operation for Releasing Device Service Field Programmable Modes Front Panel Auto configuration Computer Diagnostic Center Non volatile Data Storage Distributed Processing RS 232 Serial Output Walk Test Feature Event History Log Class A Style D or Class B Style B Zone Circuits Class A Style Z or Class B Style Y Programmable Appliance Circuits Alarm Verification Dual Rate Charger Transient Protection Expandable Southwest Park Westwood MA 02090 USA TEL 781 471 3000 FAX 781 471 3099 ISO 9001 Certified Company 1.7 SYSTEM operating system resides in an EPROM Eras Programmable Read Only Memory The system program which is defined by the user is in an EEPROM Electrically Erasable And Pro Read Only Memory and may be pro by either front panel switches or via a Friendly computer program Both of storage are non volatile system features a 500 event History Log CONTROL UNIT main System Control Unit SCU serves as a ba information and control center for standard operator self contained Programming Diagnostic Center a two digit 7 segment LED digital display pro system operation programming and internal shooting features An RS 232 port provides su output to a remote printer or video terminal power supply contains a dual rate charger The Switching Power Supply Unit can maintain sealed lead acid batteries up to amp hr capacity DEGRADE ALARM CIRCUIT 7200 Series control features Auxiliary Degrade Circuit ADAC degrade operation In the of main processor failure the LED light In the event an alarm is received each subor processor is capable of operating a general alarm the event of multiple or all processor failure the mode will operate the system in a general configuration VERIFICATION Alarm Verification feature is programmable for smoke sensors analog or conventional This allows sensors that are installed in environments prone nuisance or unwanted alarms to operate as follows the event the sensor alarms a distinctive alarm veri message will be displayed for 25 seconds The or device will then automatically reset The sys will then remain in the verification mode for a pe of approximately 85 seconds If the sensor or any sensor on the same circuit alarms within this pe a system alarm will occur If no alarm occurs this period the system will return to normal con TEST Walk Test feature is performed on a signaling line or zone basis and enables testing of the system a single individual During this test the act of plac a device in alarm will cause four pulses on the noti appliance circuits operation of a supervisory will cause three pulses while removal or dis of an initiating device will cause two The events will be recorded on a printer if one is ALARM SOUNDING notification appliance circuits on the SCU DSU DIU units can be individually programmed to acti on alarm trouble or supervisory signal from a spe addressable module sensor hardwired zone or and sound non code temporal pattern march or fixed code signals Cross zoning and by operation are readily accomplished of 4 UNITS ANALOG optional Keyboard Display Unit KDU features an alphanumeric display and 12 key keypad to en and simplify system operation by the user It may be located The Keyboard Display Unit Local is intended for mounting in the control cabinet and also provides an interface for remote units Analog Loop Unit ALU provides two 2 signaling circuits wired Class A or B Styles 4 6 or 7 Each circuit address 197 points 99 analog sensors or modules 98 and or control points ALU units configured with Field Configuration Program 5.2 or later do not require pair wire and will operate on lay wire Distributed Intelligent Unit DIU is remotely located duplicates many of the functions of the System Control SCU COMPENSATION 7200 Series continuously monitors the sensitivity of installed analog smoke sensors to measure any change in sensitivity due to the environment The drift compensa software overcomes effects of aging or environment on sensitivity giving a dependable alarm threshold and Dirty indicators are activated when a sen drifts beyond acceptable limits Sensors can automati change sensitivity with time of day to be to real life environment compensation also meets the sensitivity testing re of NFPA 72 INTEGRATED SENSITIVITY TEST analog smoke sensor is automatically tested by the software a minimum of three 3 times per day The is a recognized functional test of the ion sensor chamber photocell of the photoelectronic sensor and meets the and maintenance testing requirements of NFPA This test will give a Failed indication and identify individual sensor if it fails the test UNITS HARDWIRED hardwired units include a Quad Zone Unit with four 4 Style D Class or Style B Class initiating zone circuits an Eight Zone Unit EZU with Style B Class initiating zone circuits an Eight Daughter board EZD which gives Style D Class capability and LED annunciator output to the EZU and Eight Zone Annunciator board EZA which gives LED output to the EZU unit verification is available in the QZU and EZU units software programming AUXILIARY UNITS optional units include a Quad Relay Unit and High Current Relay Unit HRU each containing 4 individually programmable relays each relay with user switch and status The relays in these units can also be individually pro to energize either on alarm trouble or supervisory

Related Files