Gamewell-FCI ABD-2F BEAM Smoke Sensor

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-abd-2f-beam-smoke-sensor-0451832697.pdf
Type PDF
Size 665.23 KB
Downloads

Text Preview

Addressable Devices Series ABD 2F and ABD RT2F Reflected Type Beam Smoke Sensor Gamewell FCI Velociti Series ABD 2F addressable projected beam smoke is uniquely suited to sense smoke in hostile environments or open areas with ceilings where spot type sensors are unsuitable or difficult to install and It is intended for use in the signaling line circuits with the following sub E3 Series ILI MB E3 and ILI S E3 Velociti mode only S3 Series SLC PM Signaling Line Circuit Personality Module ABD 2F consists of a combination transmitter receiver unit and a reflector When enters the path between the unit and the reflector it causes a reduction in the and when the smoke level reaches the predetermined threshold an alarm unique single ended reflective design offers simpler installation than the traditional and receiver types of beam sensors Alignment is swiftly accomplished via optical sight and a 2 digit signal strength meter integral with the product Listed operation from F to 131 F the ABD 2F can be installed in garages and other hostile environments where temperature extremes exceed the of spot type sensors Velociti Series uses a communication protocol that substantially increases the of communication between the sensors and Gamewell FCI analog addressable alarm controls These devices operate in a grouped fashion If one of the devices the group changes status the panel microprocessor stops the group poll and concentrates on the single device The net effect is response up to five times greater than earlier designs unit has four standard sensitivity selections along with two Acclimate settings When either of the two Acclimate settings are selected the will automatically adjust its sensitivity using the advanced software algorithms to select the optimum sensitivity for the specific ABD RT2F is equipped with an integral sensitivity test feature consisting of a test filter attached to a servo motor inside the sensor optics ABD RT2F requires an additional external power supply Using the remote test station Model RTS 151 the motor moves the filter in the of the light beam thereby serving as an accurate test of the receiver sensitivity This test feature allows the user to quickly and easily meet annual maintenance and test requirements of NFPA 72 Information single ended beam smoke detector Single ended beam smoke sensor with integral sensitivity test Long range accessory kit required for applications with a range over 230 ft 70m Multi mount kit provides ceiling or wall mount capability with increased angular adjustment Surface mount kit Remote test station RT2F BENEFITS Includes a single Spans a 16 to 328 foot reflective to 99.9 m range Has six user selectable levels Compatible with the E3 ILI MB E3 and or the S3 SLC PM Contains an integral Provides a user Offers an integral test feature alignment Designed with a digital Available with an no special required Remote test gain control compensates for deterioration dust build up Series ABD 2F and ABD RT2F Technical Specifications Velociti Series ABD 2F and ABD RT2F are designed to with the following standard Standard UL 268 LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process factory for latest listing status S1913 3023594 FDNY COA 219 02 E Vol VI 7260 1703 0120 9001 Certification a complete listing of all approvals and please visit Velociti and Series are registered of Honeywell Inc document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice Temperature Range 22 F to 131 F 30 C to 55 C Humidity Range 10 to 93 RH non 10 H x 7.5 W x 3.3 D 25.4 H x 19 W x 8.4 D cm 16 230 ft 4.9 x 70.1 m 7.9 H x 9.1 W 20 H x 23 W cm Range 15 to 32 VDC Current 8.5 mA max Current 2 mA max avg 24 VDC AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 noncondensing at 32 2 90 3 the useful life of the system s standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore is recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 more information more about Gamewell FCI Velociti Series ABD 2F and and other products available by visiting Gamewell FCI Clintonville Road CT 06472 1610 G 11 17 Honeywell International Inc

Related Files