Gamewell-FCI AMM-4SF Addressable Monitor Module
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-amm-4sf-addressable-monitor-module-8391602547.pdf |
---|---|
Type | |
Size | 657.48 KB |
Downloads |
Text Preview
Addressable Devices Series AMM 4SF Monitor Module Gamewell FCI Velociti Series addressable monitor module AMM 4SF features a Style D Class A initiating device circuit It may also be configured as a Style B B initiating circuit with an end of line resistor This module provides an address a group of conventional 2 wire smoke detectors alarm initiating devices with normally open N O dry contacts such as the devices may also be installed in this circuit heat detectors manual stations linear heat detection devices water flow switches 4 wire smoke detectors tamper switches Velociti Series use a communication protocol that substantially increases the of communication between the sensors and certain Gamewell FCI analog fire alarm control panels These devices operate in a grouped fashion If of the devices in the group has a status change the panel microprocessor stops group poll and concentrates on the single device The net effect is response speed to five times greater than earlier designs AMM 4SF module is designed to be installed with the signaling line circuit in any analog addressable fire alarm control panel The signaling line circuits of Gamewell FCI analog addressable panels are to accommodate up to 159 monitor modules per circuit initiating device circuit of the AMM 4SF can support a maximum line resistance of up to 25 ohms This feature allows the use of linear heat devices In addition it allows the module to stay in alarm with one smoke detector activated The AMM 4SF is designed to mount in 4 square box 2 1 8 deep Information Addressable monitor module single circuit BENEFITS Accommodates up to Supports Class A Style Provides visual rotary Compact size allows or Class B Style B circuit switch 01 159 installation Only the red LED operative in panels that not operate in mode Offers 25 ohm line for each device circuit Accommodates any dry contact device Displays bi color LEDs green whenever module is and light red on alarm conventional 2 smoke detectors the Gamewell FCI P N 9000 for supported Series AMM 4SF Technical Specifications Current 00027 amps LED flashing Current 0051 amps LED lit Temperature 32 to 120 F 0 to 49 C Humidity 10 to 93 non condensing 4 1 2 L x 4 W x 1 1 4 D 11.4 x 10.2 x 3.2 cm Resistor 3.9 K ohms AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 noncondensing at 32 2 90 3 the useful life of the system standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore is recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 E3 Series Control Panel is designed to comply with following standards Standards UL 864 9th Edition 2572 for Mass Notification LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process Consult for latest listing status S1949 2572 for Mass Notification 3023594 FDNY 227 03 E Vol IV 73100 1703 0122 9001 Certification a complete listing of all approvals and please visit E3 Series and are trademarks of International document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice more information more about Gamewell FCI Velociti Series AMM 4SF other products available by visiting www Gamewell FCI com Gamewell FCI Clintonville Road CT 06472 1610 F 11 17 Honeywell International Inc