Gamewell-FCI ASD-LS Laser Sensor

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-asd-ls-laser-sensor-2085473691.pdf
Type PDF
Size 670.64 KB
Downloads

Text Preview

Addressable Devices Laser Smoke Sensor Gamewell FCI Model ASD LS is a low profile laser smoke sensor that adds new dimension to analog addressable fire detection It incorporates laser detection technology that provides an unsurpassed sensitivity and a quick to maximize detection This feature makes the sensor ultra sensitive to as much as 100 times more sensitive than conventional photo electric smoke technology innovative laser diode and precision optics design combine with an array of software tools to allow the sensor to quickly identify the fire The sensor can sense smoldering fires but yet can sense the smallest particles of combustion a faster response to flaming fires early warning capability of the ASD LS is comparable to that of Aspiration while unlike Aspirating Systems the ASD LS can pin point the location of fire sensor is continually monitored to measure any change in its sensitivity due to environment dirt temperature transient smoke humidity etc Patented distinguish between particles of dust and smoke The focused beam of the light source minimizes reflection from accumulated dust in the optical chamber minimizing problems caused by dust build up The software performs its independent analysis of the sensor signal This analysis includes dust spike drift compensation smoothing multi sensor pre alarm decision and alarm In the event of spikes in the signal the sensor will check the output of sensors for any appreciable signal to determine if the spike is caused by a flaming fire ASD LS sensor is Listed for use inside ducts up to a velocity of 4,000 FPM An isolator base Model B224BI is also available Installation of two of these bases allows Style 7 operation for sensors located electrically between the BENEFITS Operates in the or CLIP mode Provides High for both and fast fires Includes patented that ignore smoke and particles Designed with a low construction an easy plug in of head to base Offers the following features Signal processing Tamper resistant Test switch Supports a remote test originating the panel Displays 360 view of dual alarm Contains optional for auxiliary Has a maximum air 4,000 FPM Information Low Profile Analog Laser Sensor Plug in sensor base without flange 4.1 10.4 cm diameter Flanged mounting base 6.1 15.5 cm diameter Flanged mounting base bulk pack 6.1 15.5 cm diameter Plug in sensor base with auxiliary relay rated 2 amps 30 VDC resistive 2 coil relay 1 Form C Contact UL CSA Rating 0.9 A 125 VAC inductive 0.9 A 110 VDC inductive 3 A 30 VDC resistive 6.1 15.5 cm diameter Plug in sensor isolator base for Style 7 6.1 15.5 cm diameter Intelligent sensor sounder base 6.875 17.5 cm diameter Standard sounder base 6.875 17.5 cm diameter Remote LED Annunciator Extractor Test install the sensor do the following Place the sensor into the sensor base Turn the sensor clockwise until the sensor locks place To use the tamper proof feature break the tab on the base as shown in the instructions Install the sensor To remove the sensor from the base when you the tamper proof feature insert the blade of small screwdriver into the hole on the side of base and push the plastic lever away from detector head This action allows you to the sensor counterclockwise so you can the sensor from the base When you use the tamper proof feature the decorative ring before you remove the information on spacing the location of the sensors other guidelines refer to NFPA72 Chapter 5 3 Sensing Fire Detectors may be tested locally in the following ways Place a test magnet against the sensor housing per instructions The sensor should go into alarm 30 seconds The Magnet test initiates an approximately ten period when the detector s signal processing routines are not active Failure to first the Magnet Test will introduce a time delay the detector alarms Refer to the instructions the Generator Instruction Manual Aerosol Generator The Gemini Model 501 aerosol may be used to perform a Functional Test test should be performed immediately following Magnet Test programs should be adapted to the environment in compliance with the Fire Alarm Code NFPA 72 Gamewell FCI you clean the unit annually To clean the do the following Remove the sensor screen and cover assembly to the sensing chamber Use a vacuum cleaner to remove the dust from the cover and sensing chamber the complete procedure refer to the Installation Maintenance Instructions furnished with each Technical Specifications 02 2.0 ft Voltage 15 32 VDC Current 00033 amp 24 VDC Current max 0065 amp 24 VDC Temperature 32 to 100 F 0 38 C Humidity 10 to 93 relative humidity 1.7 4.3 cm height 10.4 cm installed in the B501 base 15.5 cm installed in the B210LP base 5 oz 142 gm AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 noncondensing at 32 2 90 3 the useful life of the system s standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore is recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 ASD LS is designed to comply with the following Standard UL 268 LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process factory for latest listing status S1913 3023594 7272 1703 0114 9001 Certification a complete listing of all approvals and please visit and Velociti registered trademarks of International Inc is a registered trademark Underwriter Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice more information more about Gamewell FCI ASD LS and other products by visiting www Gamewell FCI com Gamewell FCI Clintonville Road CT 06472 1610 H 11 17 Honeywell International Inc

Related Files