Gamewell-FCI B200S Sounder Base

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-b200s-sounder-base-6384915207.pdf
Type PDF
Size 643.09 KB
Downloads

Text Preview

Addressable Devices Series B200S Addressable Sensor Sounder Base B200S Velociti sounder base sets a new standard for performance installation aesthetics It is an addressable sounder base that requires a unique separate base address This sounder base is available only in Velociti protocol The is designed for new and existing dwelling unit applications It offers the flexibility in installation configuration and operation to meet or exceed the Standard 268 and UL Standard 464 requirements of the unique features of the B200S sounder base offers the functionality to the communications transmitted between the attached sensor head on the Sensor signal line loop of the E3 Series S3 Series and GWF 7075 fire alarm panels This new feature allows the E3 Series S3 Series or GWF 7075 fire control panels to use the same address as the detector but use a unique device on the loop Using the CAMWorks Tool the E3 Series S3 Series or GWF 7075 panels can then use that same address to command and activate an sounder or a group of sounders CAMWorks you can program the command set from the E3 Series S3 Series or fire alarm control panel to a specific event which allows you to select the tone and group In addition the E3 Series S3 Series or GWF 7075 fire alarm panels generate synchronization pulses through the loop and enable tone patterns its attractive aesthetics the B200S is ideal to use for applications where the is critical For example the design eliminates unsightly surface mount and the sounder base employs a separate mounting plate that can be installed various junction box sizes see Table 1 In addition the mounting plate allows you pre wire all the connections to simplify the installation To install the housing use mounting plate and secure two retaining screws to lock it in position The screws are covered by the installed sensor head to provide added tamper Information Intelligent Addressable Sensor Sounder Base bright white Intelligent Addressable Sounder Base ivory 1 The B200S WH and B200S IV produce a sound output in high or low volume with ANSI Temporal 3 ANSI Temporal 4 continuous tone tone and custom tone 2 The B200S WH and B200S IV sounder bases are compatible with the E3 Series S3 Series and GWF 7075 fire alarm control panels 1 includes information for the compatible junction boxes that can be used with the B200S Octagonal Octagonal Square Square w 3.0 mud ring mm mm mm mm 1 B200S Junction Box Selection Guide relays required BENEFITS Built in supervision no Offers a programming to control and the sounder independently Broadcasts over two levels 75 or 268 and UL 464 Complies with UL Supports Continuous Temporal 3 ANSI 4 and March tones Produces multiple tone Programs the for flexibility Includes a pre wire plate that various size boxes When the B200S is to the NAC it can be with System Sensor devices Uses a mechanical feature that the removal of attached sensor Employs coded that may be over the and promptly B200S is designed to comply with the following Standards UL 268 UL 464 LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process factory for latest listing status S1911 3035027 7300 1653 0213 9001 Certification a complete listing of all approvals and please visit Series Velociti System are registered and CAMWorks Clip are trademarks of International Inc is a registered trademark Underwriters Laboratories document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice Series B200S Technical Specifications Specifications Diameter 6.875 17.46 cm Height 2.0 5.08 cm less sensor Weight 0.50 lb 227 gm Temperature Range For the applicable Operating Temperature Range refer to the Base Cross Reference Chart at www systemsensor com Humidity Range 10 to 93 relative non condensing Specifications Supply Voltage 16 to 33 VDC VFWR Standby Current 500 uA maximum Current 35 mA maximum high volume 15 mA maximum low volume Operating Voltage 15 to 32 VDC Standby Current 300 uA maximum Output Volume Greater than 85 dBA minimum measured a UL reverberant room at 10 ft 24 Volts in continuous Volume Greater than 75 dBA minimum measured a UL reverberant room at 10 ft 24 Volts in continuous Specifications Mounts directly to 4 10.16 cm square 4 cm octagon 3 1 2 8.9 cm octagon single or double gang junction boxes Wire sizes up to 12 to 24 AWG AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 noncondensing at 32 2 90 3 the useful life of the system s standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore is recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 more information more about Gamewell FCI Velociti Series B200S and products available by visiting www Gamewell FCI com Gamewell FCI Clintonville Road CT 06472 1610 F 08 19 Honeywell International Inc

Related Files