Gamewell-FCI CH Series Chime Strobes

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-ch-series-chime-strobes-7459810326.pdf
Type PDF
Size 598.46 KB
Downloads

Text Preview

Description CH Electronic Chimes Strobes combine a unique state chime appliance with a range of strobe models unique solid state chime appliances provide field single stroke or vibrating operation with sound adjustable up to 83 dB and tone adjustable from to 1200 Hz are available in two attractive package styles for mounting to standard electrical boxes or convenient mounting CH70 model incorporates a patent pending chime plate for faster easier level installation with a aesthetic two 2 screw grill cover for a more pleasing Additionally the Series CH70 Chime Strobe incorporate the Lower Current Zero Inrush Series Non Sync Sync Strobes synchronization of the flash is achieved when used with Gamewell SM DSM sync modules or FF8 Power Supply with Patented Protocol CH Chime Strobes are designed for maximum reliability and cost effectiveness while or exceeding the latest visible signaling of NFPA 72 National Fire Alarm Code 117.1 American National Standard of Accessible Usable Buildings and Facilities and UL Standard Standard for Signaling Devices for the Hearing CH Chime Strobes when properly specified installed in accordance with NFPA ANSI Standards provide the Equivalent Facilitation allowed under ADA Guidelines ADAAG General Section 2.2 by or exceeding the illumination which results from ADA specified strobe intensity of 75 candela at 50 This is an illumination of 0.030 lumens per square incorporate a Xenon flashtube with solid state enclosed in a rugged Lexan lens to provide reliability for effective visual signaling Specifications chime appliances shall be CH Chimes Strobe The chime strobes shall be listed under UL 1971 for Signaling Devices for the Hearing In addition the strobes shall be certified to meet requirements of FCC Part 15 Class B and shall low temperature compensation to ensure the possible current consumption All chimes shall solid state components and shall provide field single stroke or vibrating operation with volume and tone control CH STROBES 1971 464 Listed State Fire Marshal CSFM of Chicago BFP Approved ADA accessbility guidelines and 29 Part 1910.165 Field Selectable single Stroke or Vibrating operation Volume and Tone Control 24 VDC Low Current Draw with Zero Inrush Terminals Accept 18 to 12 AWG Wires Polarized Inputs Flush or Surface Mount Synchronized Non Synchronized Strobes Field Selectable Candela Strobe Multi candela models Fixed Candela Models Rev 1102 6 Page 1 Specifications All models shall have a sound output of 83 dBA at 10 feet and a listed frequency response rate of 800 to 1200 Hz All inputs employ terminals that accept 12 to 18 AWG wire sizes The strobe portion of the appliance shall produce a flash of one 1 flash per second over the Regulated Input Voltage Range of 16 to 33 VDC for 24 VDC models and shall a Xenon flashtube enclosed in a rugged Lexan lens The strobe shall be of low current design and shall Zero Inrush The strobe intensity shall have a minimum of four 4 field selectable settings and shall be rated per UL for 15 30 75 or 110 candela wall mount versions The switch for selecting the candela setting shall be located on rear of the appliance in order to prevent tampering from unauthorized persons When synchronization is required the portion of the appliance shall be compatible with the SM DSM sync modules or FF8 Power Supply The strobes not drift out of synchronization at any time during operation If the sync module or Power Supply fails to operate i e remain closed the strobe shall revert to a non synchronized flash rate The chime and the chime strobe shall be designed for indoor surface or flush mounting The Chime Strobe shall be Gamewell MOdel 72041 72042 No Model 10 Anechoic Peak dBA 10 Max 58 58 Chime Only Chime Only 085 CH70 24MCW FR CH70 24MCW FW CH70 241575W FR 15 75 Multi candela Average Strobe Current 24VDC 30CD 75CD 110CD Strobes are designed to flash at 1 flash per second minimum from 20 31VDC Note that NFPA 72 1999 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second All candela ratings represent minimum effective strobe intensity based on UL 1971 Series CH Strobe products are UL 1971 for indoor use with a temperature range of 32o F to 120o F 0oC to 49oC and maximum humidity of 85 Information Number Series provide Synchronized Strobe with 71548 or 71549 Sync Modules Candela Chime Strobe Wall Mount 24VDC Red CH70 24MCW FR Candela Chime Strobe Wall Mount 24VDC White CH70 24MCW FW Chime Strobe 065 Amp Wall Mount 24VDC Red CH70 241575W FR Description Accessories for CH Series Chime Strobes 4 Sq Deep w Extension Ring Surface Mount 5 1 2 x 5 9 16 x 3 9 16 Red SBB R Surface Mount 10 15 16 x 6 7 64 x 1 11 16 Red SBL2 R Semi Flush 6 Square x 5 16 D Red SFP R Extender 5 1 4 Square x 25 32 D Red ISP R Plate 8 x 5 7 8 x 13 32 Red RP R Items purchased by others For more details refer to CS 2248 and wiring information are provided for information only and are believed to be accurate Gamewell assumes no for their use Data and design are subject to change without notice Installation and wiring instructions shipped with the shall always be used for actual installation For more information contact Gamewell Gamewell Company Pleasant St MA 01721 in the USA 508 231 1400 888 347 3269 508 231 0900 2002 Rev 1102 6 Page 2

Related Files