Gamewell-FCI CO1224T Conventional Carbon Monoxide 4-Wire Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-co1224t-conventional-carbon-monoxide-4-wire-detector-5168973240.pdf |
---|---|
Type | |
Size | 667.80 KB |
Downloads |
Text Preview
CO1224 Series Monoxide Detectors RealTest Technology Monoxide Detectors RealTest Technology Series The CO1224T and CO1224TR detectors comply with Standard 2075 The CO1224A detector complies with ULC Standard 6.19 01 a 10 year end of life timer Provides a RealTest that enables a functional test canned CO Offers a code required Trouble Relay Uses SEMS terminals for wiring supervision Wired for 12 24 VDC Supports a low current draw of 20 mA in standby and Designed with a versatile mounting used for wall and mA in alarm installations technology Employs a highly accurate and reliable electrochemical Contains an optional CO PLATE CO Detector Replace Plate to upgrade previously installed competitor to the CO1224T or CO1224A Tested CO1224T up to 12,000 feet above sea level E304075 CO1224TR Gamewell FCI CO1224 Series comprise the following Monoxide CO Detectors CO1224T CO1224A Canada Carbon Monoxide detectors use a highly accurate and reliable electro sensing cell to provide an early warning of dan carbon monoxide CO levels CO1224 Series detectors are designed for system These detectors are listed to the following stan UL Standard 2075 US models only CSA 6.19 01 Canada model only addition they offer a code required trouble relay to send sensor failure or end of life signal to the fire alarm control and the Central Station CO1224 Series detectors use SEMS type terminal head screws for quicker and more positive wiring and code required wiring supervision With a current draw these detectors allow more devices to be to the panel limiting the need to purchase extra supplies or more expensive panels As 12 24 VDC the CO1224 Series detectors operate on most security and fire alarm control panels the detector identifies dangerous amounts of CO in area the CO1224 Series CO detectors alert the resi with signals that sound and flash a temp 4 signal The 24 7 Central Station Monitoring feature guaran protective security to the property and the resident safety whether the residents are sleeping or already from the effects of carbon monoxide poisoning the RealTest Technology the CO gas sensing cell in the CO1224 Series CO detectors can be tested a CO gas agent that complies with the requirements NFPA 720 2009 US models only See the reverse or the user manual for complete instructions Mode Activation activate the RealTest mode do the following Place the detector into the RealTest mode Spray a small amount of CO into the detector per the Instructions Within seconds the detector goes into alarm indicat a successful gas enter is a registered trademark of Honeywell International Inc is a registered trademark of Underwriters Laboratories GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved Rev A page 1 of 3 Specifications Voltage Signal Current Current Contact Ratings Contact Ratings VDC dB in alarm mA mA 75 mA test A 30 VDC A 30 VDC Specifications Dimensions CO1224T CO1224A CO1224TRL x 1.3 x 5.1 W x 33 H x 130Lmm H x 6.0 D H x 152 D mm Approximate Weight CO1224T CO1224A CO1224TR Temperature Humidity Range 22 to 90 RH Terminals to 22 AWG back box mount to wall or oz 198 g 11 oz 312 g to 104 F 0 to 40 C end of life Series Detectors Carbon Monoxide Specifications Continued Specifications Continued Carbon monoxide CO detector shall be a system Gamewell FCI model part number CO1224T or listed to Underwriters Laboratories UL Stan 2075 for Gas and Vapor Detectors and Sensors The model CO1224A is ULC listed to CSA 6.19 01 residential carbon monoxide alarm devices The detec shall be equipped with a sounder and a trouble relay detector base can be mounted to a single gang elec box or direct surface mount used for wall or ceiling Wiring connections shall be made by means SEMS screws detector shall provide dual color LED indication that to indicate the following conditions normal standby alarm the sensor supervision is in a trouble condition the shall send a trouble signal to the panel When the gives a trouble or end of life signal the detector be replaced The detector shall provide a way to test gas entry into the CO sensing cell The detector shall this with a test mode that accepts CO gas from a agent and alarms immediately upon sensing CO entry the CO1224T only the detector shall perform in the of CO up to 12,000 feet above sea level and within the time specified by ANSI UL Standard 2034 CO concentrations of 70 150 and 400 parts per million as verified by a Nationally Recognized Test Labora Carbon monoxide CO detector shall be a system Gamewell FCI model part number CO1224T or listed to Underwriters Laboratories UL 2075 for and Vapor Detectors and Sensors The Canadian CO1224A is ULC listed to CSA 6.19 01 for resi carbon monoxide alarm devices The detector shall equipped with a sounder and a trouble relay The detec base can mount to a single gang electrical box or surface mount to the wall or ceiling Wiring connec shall be made by means of SEMS screws Rev A page 2 of 3 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 Modes Mode standby Feature Check with local codes the AHJ to determine if a gas test is desired for installation LED 1 per minute LED Gamewell FCI CO1224 Series CO Detectors enable evaluation of the functionality of the CO cell using a canned CO test agent in temp 4 pattern in temp 4 pattern To enter the RealTest mode Spray canned CO agent Verify CO sensing at the 2 the detector 3 panel After 20 60 seconds the automatically exits RealTest alarm mode 1 and hold the Test button for two sec The green LED flashes every second to indi the RealTest mode Feature Feature Timer silence the sounder for five minutes except in RealTest push the Test Hush button the detector is in a trouble condition the detector sends a Signal to the fire alarm control panel the detector internal sensor reaches the end of life the sends a Trouble Signal to the fire alarm control panel to it is time to replace the detector An electrochemical CO detector lifespan is approx ten The detector must be replaced by the date marked on the of the product also offers the CO PLATE CO Detector Replace Plate to cover the footprint when necessary of previously competitive carbon monoxide detectors that require 4 Information Number Description volt 6 wire system monitored carbon monoxide detector with RealTest Technology US only volt 6 wire system monitored round carbon monoxide detector with RealTest Technology US only volt 6 wire system monitored carbon monoxide detector with RealTest Technology Canada only detector replacement plate to cover the footprint of previously installed competitive detectors US Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 Rev A page 3 of 3