Gamewell-FCI Conventional Duct Detector Housing

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-conventional-duct-detector-housing-3169274508.pdf
Type PDF
Size 666.12 KB
Downloads

Text Preview

Features Photoelectric or Ionization Two form c alarm contacts Remote reset and test 24 VDC or universal input Remote alarm LED Form C trouble contact Two or four wire operation Mounting template and hardware and approvals below to the basic Conventional Smoke Detectors In some certain modules may not listed by certain approval or listing may be in Consult factory for listing status UL Listed Duct Detectors Gamewell FCI conventional duct detectors provide early detec of smoke and products of combus present in air moving through an duct These devices are de for prevention of smoke recircu by the air handling systems blowers and complete systems be shut down or activated into mode operation in the event of detection Gamewell FCI Duct Smoke Detector may use a photoelectric or ionization head A visual alarm indicator is mounted on the housing front for sta indication A manual reset switch is provided on the front of the detector sampling is accomplished by two tubes which protrude into the duct An tube of one standard length of 7.5 19.05 cm is provided with the housing Intake sampling tubes which must be ordered separately are in three standard lengths 2.5 5.0 or 10.0 feet 0.76 1.524 or 3.048 features of the duct type smoke detectors include a local red LED indicator local functional test reset capability provisions for remote test alarm indication and connections for remote reset switch Specifications smoke detectors shall be the Gamewell FCI series for two wire or four 24 VDC operation use model 30954 ionization or 30955 photoelectric voltage models are 70957 01 ionization or 70958 01 photoelectric detectors shall be Listed by Underwriters Laboratories per UL 268A The shall operate at air velocities from 300 to 4,000 feet 31.44 to 1219.2 per minute duct detector housing shall have a metal chassis with a plastic cover and installation may be performed without removal of the detector cover indication of alarm must be provided on the detector front mounted at a slant to provide a wide viewing angle A manual reset test switch shall be on the front of the device heads shall not require additional filters or screens which must be The housing shall contain a detector base which will accept photo or ionization heads Terminal connections shall be of the screw type be a minimum of a 6 screw Terminals shall be provided for remote alarm and remote reset test switches All wiring must comply with local and regulations Diagram Duct CS 2056 A 1 of 2 Information smoke detector for air duct 2 wire or 4 wire VDC 2650 560 smoke detector for air duct 2 wire or 24 VDC 2650 561 Remote LED alarm indicator 2 VDC for models and 30955 Remote test station for models 30954 and 30955 relay for power supervision 24 VDC for 30954 and 30955 duct smoke detector universal voltage 24 VAC 24 VDC RWH N Photoelectric duct smoke detector universal voltage VAC 24 VAC 24 VDC RWH P LED alarm indicator 24 VDC for models and 70958 01 test station for models 70957 01 and 70958 01 Sampling tube 2.5 ft 0.762 m Sampling tube 5.0 ft 1.524 m Sampling tube 10.0 ft 3.048 m detector head replacement detector enclosure WP 1 see CS 2308 temperature to 120 0 to 49 to 85 relative humidity steel back box Plastic cover grey finish with clear H x 8.25 W x 2.25 D 25.4 H x 21.0 W x 5.7 D net weight lbs 1.814 kg element ionization versions only 241 1.0 microcuries velocity to 400 feet m 91.44 to per minute differential 1.2 inches cm 0.01 of water requirements 30954 and 30955 24 VDC at 0.00005 A standby A alarm 70957 01 and 70958 01 VAC operation at 0.02 A 0.035 A alarm 24 VAC at 0.061 standby 0.16 alarm 24 VDC operation at A standby 0.07 A alarm contact rating 30954 and 30955 alarm two Form C rated at amp 30 VDC 70957 01 and 70958 01 contacts two Form C at 10.0 A at 115 VAC trouble contacts one rated 4.0 amps at 115 resistive CT 06472 1610 Clintonville Road 203 484 7161 203 484 7118 Honeywell Company 2009 Gamewell FCI and wiring information are provided for information only and are to be accurate Gamewell FCI assumes no responsibility for their use and design are subject to change without notice Installation and wiring shipped with the product shall always be used for actual installation For information contact Gamewell FCI 2 of 2 Duct CS 2056 A

Related Files