Gamewell-FCI CZI-95 Conventional Zone Interface
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-czi-95-conventional-zone-interface-4691870523.pdf |
---|---|
Type | |
Size | 623.54 KB |
Downloads |
Text Preview
Addressable Devices Zone Interface Gamewell FCI Conventional Zone Interface CZI 95 is designed as the interface the 600 Series and ILI95 E3 Series fire alarm control panel FACP analog and the normally open contact devices or conventional smoke detectors The Zone Interface device monitors up to 25 conventional detectors You use the Conventional Zone Interface modules with Style B C D or E wiring Conventional Zone Interface can monitor up to 25 conventional smoke detectors a three wire circuit The CZI 95 acts as a remotely located conventional zone It a supervised circuit to connect to conventional type devices such as smoke or contact devices If any detector on the CZI 95 circuit goes into alarm CZI 95 will report its own address to the main control panel via the analog circuit the FACP will initiate the programmed response The LEDs on the conventional and the CZI 95 will both light indicating that the device is in alarm a trouble is detected on the monitored circuit the CZI 95 will report the trouble to the FACP The CZI 95 will detect troubles from either the field wiring or a device Conventional Zone Interface device can be either surface or flush mounted and an LED for annunciation The CZI 95 mounts in a standard 4.0 x 4.688 x 11.908 cm or double gang electrical backbox The CZI 95 should be in an easily accessible location so that the built in LED indicators may be seen and display the proper connection and device activation program the CZI 95 set a single DIP switch on the device printed circuit board Information Conventional zone interface for monitoring contact devices or conventional detectors for FACP analog circuits Monitors up to 25 conventional detectors protocol compatible Trim ring for flush mounting the CZI 95 BENEFITS Compatible with the 600 and ILI95 E3 analog FACPs Monitors up to 25 open contact Provides an LED for annunciation Uses either surface or Monitors conventional mounted detectors Field programmable Available for Style B C and E wiring Contains screw for field connections Technical Specifications Current 0.010A Alarm Current 102A Temperature 32 to 120 0 to 49 Humidity 93 non condensing 4.0 x 4.688 x 11.908 cm double gang backbox 600 Series and ILI95 E3 Series analog circuit can up to 40 CZI 95s However the IF610 system can up to 40 CZIs in total per system with a maximum of 40 CZI 95s per a single circuit SPECIFICATIONS interface devices shall be provided for the and supervision of conventional type devices to the Fire Alarm Control Panel The modules monitor either normally open dry contact type or shall provide a remote conventional zone as on the drawings The remote conventional zone be programmable for alarm verification and shall the capacity to monitor up to 25 conventional smoke The addressable devices shall to the main control panel via the analog circuit The device shall be Gamewell FCI CZI 95 and shall be capable of ANDing Type Zones cross zoning Each 600 Series and ILI95 E3 Series circuit can support up to 40 CZI 95s However the system can support up to 40 CZIs in total per with a maximum loading of 40 CZI 95s per a circuit CZI 95 is designed to comply with the following STANDARDS Standard 864 9th Edition LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process Consult factory for the latest listing status Listed S521 Approved Approved 7300 1703 0135 9001 Certification a complete listing of all approvals and please visit Series is a registered of Honeywell Inc Windows is a trademark of Corporation document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice of origin U S A Gamewell FCI Clintonville Road CT 06472 1610 D 04 19 Honeywell International Inc