Gamewell-FCI DNR DNRW Duct Smoke Housing

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-dnr-dnrw-duct-smoke-housing-4810956372.pdf
Type PDF
Size 717.58 KB
Downloads

Text Preview

InnovairFlex Series Duct Housing Non Relay Duct Smoke Housing Photoelectric integrated low flow technology Air velocity rating from 100 ft min to 4,000ft min to 20.32m sec Versatile mounting options square or rectangular Broad ranges for operating temperature 4 to 158 humidity 0 to 95 non condensing Patented sampling tube installs from front or back of the with no tools required New Cover tamper signal wiring space with a newly added 3 4 inch knockout Available space within housing to accommodate the of the relay module Easily accessible code wheels on sensor head sold Clear cover for convenient visual inspection UL 268A Listed Remote testing capability Requires SLC line power only NEMA Type 4 UL Listed for non hazardous indoor and applications DNRW only UV Resistant UL Listed housing and cover material only 7272 1703 0121 S911 InnovairFlex Series DNR intelligent non relay pho duct smoke detector and the DNRW watertight photoelectric duct smoke detector feature a piv housing that fits both square and rectangular foot These detectors are capable of mounting to a round rectangular duct The DNR DNRW detectors can be with the E3 Series and 7100 Series Systems The InnovairFlex Series DNR requires the Veloc Series ASD PL2FR Sensor and AOM 2RF if relays required for the fan control DNRW duct smoke detector with its NEMA 4 rating is as a watertight enclosure providing protection falling dirt rain and windblown dust splashing and directed water These features allow operators to use detector in the most extreme environments units sense smoke in the most challenging conditions in airflow speeds of 100 to 4,000 feet per minute of 4 to 158 and a humidity range of 0 to percent non condensing improved cover design isolates the sensor head from low flow feature for simple maintenance A cover tam feature was added to indicate a trouble signal for a or sensor cover The housing provides a 3 4 inch conduit knockout ample space to facilitate easy wiring and mounting of relay module InnovairFlex duct smoke detector can be customized meet local codes and specifications without additional The new InnovairFlex product line is compatible all previous Innovair models including remote test smoke detectors have specific limitations SMOKE DETECTORS ARE a substitute for an open area smoke detector a substitute for early warning detection and NOT a for a building regular fire detection system to NFPA 72 and 90A for additional duct smoke 2911 application information Series and Velociti are registered trademarks and InnovairFlex is a of Honeywell International Inc is a registered trademark of Underwriters Laboratories Inc GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved www gamewell fci com Rev E page 1 of 4 Specifications air duct smoke detector shall be a System Sensor InnovairFlex DNR Intelligent Non Relay Photoelectric Duct Detector and DNRW Watertight NEMA4 Duct Smoke Detector The detector housing shall be UL Listed per UL specifically for use in air handling systems The flexible housing of the duct smoke detector fits both square and footprints The detector shall operate at air velocities of 100 ft min to 4,000 ft min 0.5 m sec to 20.32 m The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly It shall be capable of local testing via magnetic switch or remote testing using the RTS151KEY remote test Terminal connections shall be of the strip and clamp method suitable for 12 AWG wiring in 19.7 cm Length 9 in 22.9 cm Width 2.5 in 6.35 cm Depth lb 0.73 kg DNRW only Specifications Dimensions 14.38 in 37 cm Length 5 in 12.7 cm Width 2.5 in 6.6 cm Depth Dimensions Rating Temperature Temperature Humidity Duct Velocity if included to 95 relative humidity non condensing to 4000 ft min 0.5 to 20.32 m sec 26.4 VDC 95mA max to 158 to 70 to 158 to 70 Ratings information on the electrical specifications refer to the InnovairFlex DNR Duct Smoke Detector Installation P N I56 3051 001R Current Loads at 24 VDC mA mA mA Max mA Max the InnovairFlex Sampling Tube InnovairFlex sampling tube may be installed from the front or back of the detector The tube locks securely into and can be removed by releasing the front or rear locking tab Figure 3 illustrates the front locking tab 1 2 3 Rev E page 2 of 4 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 for Intelligent Non Relay Duct Smoke Detector 4 System Wiring Diagram for DNR 5 DNR to RA100Z TO RTS451 RTS451KEY RTS151 WITH REMOTE TEST DETECTOR HEAD OPTION COIL COIL CONV ONLY POWER COIL COIL CONV ONLY TEST STATION OPTION PER UNIT COIL OPTION PER UNIT CURRENT DRAW Figure 6 DNR to RTS151 RTS151 Key Notes The use of either RTS151 or RTS151KEY requires the installation of an accessory coil DCOIL sold separately additional information refer to the DNR or DNRW Duct Smoke Detector Installation Instructions I56 3051 001R and the Duct Application Smoke Detectors Application Guide The RTS151 RTS151KEY test coil circuit requires an external 24 VDC power supply which must be UL Listed Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 Rev E page 3 of 4 Sensor provides system flexibility with a variety of accessories including two remote test stations and different of visible and audible system annunciation As with our duct smoke detectors all duct smoke detector accesso are UL Listed 7 RTS151 UL S2522 8 RTS151KEY UL 9 RA100Z UL S2522 10 ASD PL2FR Information Number non relay photoelectric low flow duct smoke detector intelligent non relay photoelectric low flow duct smoke detector photoelectric smoke sensor with remote test capability in duct applications Number Remote annunciator alarm LED test coil required with RTS151 RTS151151KEY sampling tube duct width up to 1 ft 0.3m sampling tube duct widths 1 ft to 2 ft 0.3 to 0.6 m sampling tube duct widths 1 ft to 2 ft 0.3 to 0.6 m sampling tube duct widths 2 ft to 4 ft 0.6 to 1.2 m sampling tube duct widths 4 ft to 8 ft 1.2 to 2.4 m sampling tube duct widths 8 ft to 12 ft 2.4 to 3.7 m enclosure exhaust tube duct width 1ft 0.3m magnet cap for metal sampling tubes test station test station with key lock Rev E page 4 of 4 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118

Related Files