Gamewell-FCI E3 Series A E Specification - Stand Alone (PDF)

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-e3-series-a-e-specification-stand-alone-pdf-4653198207.pdf
Type PDF
Size 977.66 KB
Downloads

Text Preview

9020 0656 C Gamewell FCI Fire Clintonville Road Connecticut 06472 1653 484 7161 484 7118 2019 Guide Specification Notes This product guide specification is written according to the Construction Specifications CSI 3 Part Format as described in The Project Resource Manual Manual of Practice section must be carefully reviewed and edited by the Architect or Engineer to meet the of the project and local building code Coordinate this section with other specification and the Drawings Delete all Notes when editing this section numbers and titles are from MasterFormat 1995 Edition with numbers and titles from 2004 Edition in parentheses Delete version not required 13850 28 31 00 ALARM SYSTEM Notes This section covers Honeywell Gamewell FCI E3 Series Expandable Emergency Fire Alarm System Consult Honeywell Gamewell FCI for assistance in editing this section the specific application 1 INCLUDES Emergency evacuation fire alarm system SECTIONS Section 13800 Building Automation and Control Section 13900 21 00 00 Fire Suppression Series Fire Alarm System 28 31 00 1 Notes Edit the following list of related sections as required for the project List other sections work directly related to this section Section 27 15 00 Communications Horizontal Cabling Notes List standards referenced in this section complete with designations and titles This does not require compliance with standards but is merely a listing of those used Electrical Industries Association EIA RS 232 D Interface Between Data Terminal Equipment and Data Circuit Terminating Employing Serial Binary Data Interchange RS 485 standard defining the electrical characteristics of drivers and receivers for use in digital multipoint systems National Fire Protection Association NFPA NFPA 12 Standard on Carbon Dioxide Extinguishing Systems NFPA 13 Installation of Sprinkler Systems NFPA 15 Standard for Water Spray Fixed Systems for Fire Protection NFPA 16 Standard for the Installation of Foam Water Sprinkler and Foam Water Spray NFPA 16A Standard for the Installation of Closed Head Foam Water Sprinkler Systems NFPA 17 Dry Chemical Extinguishing Systems NFPA 17A Wet Chemical Extinguishing Systems NFPA 70 National Electrical Code NEC NFPA 72 National Fire Alarm Code NFPA 2001 Clean Agent Extinguishing Systems NFPA 90A Standard for the Installation of Air Conditioning and Ventilating Systems NFPA 101 Life Safety Code NFPA 750 Standard on Water Mist Fire Protection Systems NFPA 5000 Building Construction and Safety Code Underwriters Laboratories UL UL 268 Standard for Smoke Detectors for Fire Alarm Signaling Systems UL 864 9th Edition Standard for Control Units and Accessories for Fire Alarm Systems UL 1971 Standard for Signaling Devices for the Hearing Impaired a UOJZ Control Units System b SYZV Control Units Releasing Device UOXX Control Unit Accessories System DESCRIPTION A new intelligent reporting microprocessor controlled fire detection and notification system shall installed in accordance with the specifications and as indicated on the Drawings Each Signaling Line Circuit SLC and Notification Appliance Circuit NAC Limited to only 80 of its total capacity during initial installation C Control Panel shall be expandable from 2 to 128 SLC loops as necessary to accommodate expansion Basic Performance Series Fire Alarm System 28 31 00 2 Line Circuits SLC Serving Addressable Devices Wired Class A Device Circuits IDC Serving Non addressable Devices Connected to Monitor Modules Wired Class A Notification Appliance Circuits NAC Serving Strobes and Horns Wired Class A On Class A Configurations Single ground fault or open circuit on Signaling Line Circuit not cause system malfunction loss of operating power or ability to report alarm Signals Arriving at Control Panel Not lost following primary power failure until signal is processed and recorded Network Node Communications System shall have the capability of networking with other Control Panels on single of copper wires or fiber optic cables Line Circuits SLC Reside in remote panels with associated audio zones SLC modules shall operate in peer to peer fashion with all SLC modules in the Panel On loss of an SLC module each remaining panel shall continue to communicate with of system including all SLC and control functions NAC Circuits Arranged such that there is a minimum of 1 audible device per fire alarm NAC Circuits Notification Appliance Circuits NAC and Control Equipment Arranged such that loss of 1 NAC circuit will not cause loss of any other NAC circuit in system Electrically supervised for open and short circuit conditions short circuit exists on NAC circuit it shall not be possible to activate that circuit Basic System Functional Operation When fire alarm condition is detected and reported by 1 of system alarm initiating devices the following functions shall immediately occur Alarm LEDs Flash Piezo Electric Signal in Control Panel Sound at a pulse rate LCD Display Indicate all information associated with fire alarm condition type of alarm point and its location within protected premises Historical Log Record information associated with fire alarm control panel condition with time and date of occurrence output programs assigned via control by event equations to be activated by point in alarm shall be executed and the associated system outputs alarm appliances and or relays shall be activated Strobes flash synchronized continuously devices sound continuous Temporal pattern until system is reset Alarm System Functionality complete electrically supervised distributed Class A networked fire alarm and control system with analog initiating devices Alarm System E3 Series multiprocessor based control panel one or more Intelligent Interface ILI MB E3 or ILI95 MB E3 and 80 character LCD annunciator Intelligent Network Transponders INX communicating over peer to peer token network with standard capacity of 64 nodes expandable to 122 ILI MB E3 or ILI95 MB E3 SLC module Incorporate 2 Signaling Line Circuits with capacity to support up to 159 analog addressable detectors and 159 modules per SLC or support in Apollo mode up to 126 detectors and modules ILI95 MB E3 SLC Series Fire Alarm System 28 31 00 3 Control Panel shall incorporate Boolean control by event programming including as a AND OR NOT and Timer functions Control Panel shall have the capability to accept firmware upgrades via connection with computer without requirement of replacing microchips Control Panel shall have the capability of having an integral DACT digital alarm transmitter that can report to single central station monitoring account Control Panel shall have the capability of storing its entire program and allow installer to only devices that are installed during construction without further downloading of Protection Each system shall be provided with 4 levels of password protection up to 16 passwords Network Based on peer to peer token ring technology operating at 625 K baud using Class A Capability of using twisted pair wiring pair of fiber optic Multi mode cable strands up 200 microns or Single mode optimized for 9 125 microns or any combination to flexibility in system configuration Each Network Node Capability of being programmed off line using Windows based software supplied by alarm system manufacturer Capability of being downloaded by connecting THE computer into any other node in system Systems that require system to be downloaded to each transponder at each transponder location shall be acceptable Capability of being grouped

Related Files