Gamewell-FCI E3 Series®, Broadband
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-e3-series-broadband-8240536791.pdf |
---|---|
Type | |
Size | 768.72 KB |
Downloads |
Text Preview
Voice Evacuation Series Broadband System Networked Multi Channel Fire Alarm Control Emergency Voice Evacuation System Gamewell FCI E3 Series Broadband System is a modular design and offers a range of configurations from two basic sub assemblies These sub assemblies an integrated distributed fire alarm system that includes audio evacuation and command capability network communication transmits all fire alarm audio evacuation voice paging fire fighter communications This System can be used as a component of the E3 Series Systems E3 Series Broadband Voice Evacuation System E3 Series Combined Fire and Mass Notification System E3 Series Broadband System is a revolutionary advance in fire detection and voice evacuation system design E3 Series Broadband employs proven and expands it to accomplish emergency multi channel voice evacuation fire fighter communications and building control applications while sent over a single pair of wires or fiber optic cable is a true peer to peer token ring passing networked system capable of supporting to 64 individual nodes In addition the Addressable Node Expander ANX board the network to 122 nodes All system status control by event sequences voice paging and fire fighter telephone signals are sent between nodes over a pair of wires or fiber optic cable E3 Series Broadband node can be spaced along the network a maximum of 3,000 feet 914.4 m over an unshielded twisted pair of wires or fiber cable with signal loss up to 8dB loss Built in isolation at each node permits Style 6 and 7 network configurations E3 Series Broadband is simple to configure for any project requirement A E3 Series Broadband application can be assembled from the following of nodes ILI E3 ILI95 E3 Series ANX INCC Command Center INX Transponder Series Broadband FM UL Listed for Pre Distributed Integrates INX Uses state of the art BENEFITS IBC Seismic Certified Listed under UL 864 9th Listed under UL UL2572 for Notification UL Listed for smoke dedicated and when configured use All communication and control by sequences over a pair of twisted wires or cable including 7 wiring allow components to normal with no loss function during line fault and INCC centers to a complete evacuation with up to 122 Redundant command with and fire handset are configured by INCCs signal processor technology for audio and Provides up to 150 of audio power 3 AM 50 Series with an 50 watts of power in each Network INX E3 Series Broadband System is capable of the sophisticated sequences of operations The Configuration Program FCP is based on logic statements providing AND OR NOT XOR logic operators These operators can be to produce additional Boolean operators as NAND NOR XNOR The E3 Series Broadband software programmable for multi channel digital applications It is ideal for use with a wide range complex system applications including high rise or installations An array of cabinets allows for compact installations comprehensive set of timing functions can be to any input output logic statement for the reset of fan control relays time delayed activation automatic The E3 Series control is a microprocessor based fire alarm control that uses the following ILI E3 ILI95 E3 Series Intelligent Loop Module or ANX with two signaling line circuits Two notification appliance circuits the E3 Series control panel transmits to remote the optional RPT E3 provides the ILI E3 Series or the ANX with signal boosting and protection as well as connectivity for both and fiber optic cables Other options also include integral Digital Alarm Communicator Transmitter that supports most popular reporting formats Intelligent Network Command Intelligent Network Command Center INCC as the central point of interface between an and the system audio evacuation fire intercom and building network The INCC a single address on the E3 Series network A typical INCC assembly consists the following Intelligent Network Interface Voice Gateway INI Generation or INI VGC UTP fiber or unshielded twisted pair modules One or more Addressable Switch Modules Optional Network Graphic Annunciator NGA Remote 48 LED driver module ANU 48 component options include a paging and a fire fighter handset that connects the INI VGC Third Generation or INI VGC UTP Each INI VGC Third Generation or INI VGC module can support up to 16 ASM 16 modules ASM 16 has 16 push button switches for a capacity of 256 switches per INI VGC center Each switch has three associ LEDs colored green yellow and red These and their LEDs that are fully programma to serve any system function desired These and LEDs can control the following audio speaker circuits addressable relay outputs notification appliance circuits fire fighter phone control circuits any other special application that might be INCCs can be configured into the E3 Broadband network to serve as a completely command center to operate either for local area or to operate as remote command mimicking in part or in whole the function a main command center ILI MB E3 ILI95 MB E3 Intelligent Network Transponder Intelligent Network Transponder INX acts as network audio transponder for the E3 Series Network The INX transponder serves the point of distribution for the system audio fire fighter telephone circuits and occupies a node on the E3 Series Broadband network typical INX assembly consists of the following ANX INI VGX Module ILI S E3 ILI95 S E3 PM 9 PM 9G power supply Up to four AM 50 Series amplifiers INX transponder occupies a single address on the and provides termination points for the connection using either a pair of unshielded wire or fiber optic cable INX transponder receives its power from a PM 9 9 ampere filtered switching power supply 24 VDC nominal operating voltage The PM has an integral standby battery charger of recharging up to 55 A H batteries The cabinet can house up to 18 A H batteries Intelligent Network Interface Gateway INI VGX uses advanced Digital Signal Processing technology for audio compression and filtering the E3 Series Broadband to produce a audio tone while conserving network to broadcast an instantaneous response noise is automatically filtered during paging and fire fighter communications audibility and eliminating the need for devices INI VGX can accommodate up to 16 different with a total combined duration of three Each message can be field installed via a Intelligent Network Interface Gateway computer and setup to broadcast a voice or an evacuation tone INI VGX also provides a fire fighter phone riser an addressable signaling line circuit that can to multiple phone jacks or warden stations as many as 16 AOM TELF modules In the INI VGX SLC can support up to 32 circuits using the AOM 2SF for single applications Series Amplifiers INX or INX CAB B cabinet can contain up to four Series amplifiers that produce 50 watts of either 25 VRMS or 70.7 VRMS audio output amplifier includes two separate speaker circuits can be wired Style Y Class B or Style Z Class A addition each amplifier can produce its own tone or independently of other system amplifiers an INX transponder can produce three audio simultaneously Each INX transponder can up to four AM 50 Series amplifiers operating main amplifiers with one AM 50 Series amplifier as a fail safe backup amplifier 1 illustrates the INCC Command Center and the INX Cabinet Series with notificat