Gamewell-FCI E3 Series® Expandable Emergency Evacuation System
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-e3-series-expandable-emergency-evacuation-system-2684103597.pdf |
---|---|
Type | |
Size | 690.31 KB |
Downloads |
Text Preview
E3 SERIES FIRE ALARM CONTROL PANEL Emergency Evacuation System E3 Series fire alarm control panel is a modular emergency evacuation fire E3 Series Expandable Emergency System by Gamewell FCI is in the of the latest generation of fire alarm panels The E3 Series System for use in virtually any application it features a modular assembly that is the new high speed Velociti the E3 Series provides previously polling speed and response with the flexibility demanded by emergency evacuation systems In to the sensors high speed polling the Velociti Series of sensors feature bi LEDs that flash green for normal polling light red steadily to indicate an alarm AND BENEFITS E3 Series is equipped with an LCD E3 alphanumeric LCD 4.3 color touchscreen LCD SLP Up to six keyboard LCD displays may remotely located In addition you can five of the familiar LCD 7100 RAN remote displays The displays show system status information and can be in any desired area of an Offers Class B Class A or Class X signaling circuits IBC Seismic Certified Listed under UL Standard 864 10th Edition Listed under UL Standard UL 2572 for Mass UL Listed for smoke control dedicated and when properly configured UL Listed and FM Approved for Pre action and Agent Releasing Provides two to 244 SLCs each supporting sensors 159 modules and 159 sounder bases 625K bits per second ARCNET using wire fiber or mixed for installation flexibility High speed 32 bit processor and 8100 event log Advanced Boolean logic based such as AND OR NOT time and calendar functions configurable computer programming Supports up to 16 ASM 16 addressable or ANU 48 LED driver modules per Two Class A or Class B notification appliance rated at 2.0 amps per circuit Integral city connection Up to 9 levels of sensitivity adjustment Flexible 115,200 baud high speed RS 232 40 character user defined text per device Supports the following LCD SLP displays annunciators LCD E3 displays annunciators LCD 7100 RAN 7100 remote LED per ILI MB E3 Polls 318 devices in less than two seconds Activate up to 159 outputs in less than five Test LED blink associated device address during Fully digital high precision protocol Drift compensation Pre Alarm adjustable between 15 levels for Alert and Action Day night automatic sensing adjustment windows 0.05 2 obscuration 1 3 obscuration 0.02 2 obscuration Series with Display Series with Display MCS Acclimate 2.5 4 also self adjustable HARSH 1 3 obscuration Each Loop Card has its own integral providing maximum survivability loss of any other component SLC full response on loss of any other processor Optional programmable switches can be to enable disable or group any of output devices Integrated point or Grouped Cross Zoning for numerous devices installed at any to cooperate and determine alarm Automatic detector sensitivity testing Signals DIRTY and VERY DIRTY detector alerts the Cabinet B C and D backboxes the ANX appears in the same place the ILI MB E3 ILI95 MB E3 and PM 9 PM 9G For information on installation instructions for any of the E3 Series cabinets refer to E3 Series Expandable Emergency Evacuation Manual Part LS10080 051GF E other options including information on the system compatibility the retrofit equipment refer to the panel s installation manual or the Compatibility Addendum for Gamewell Manuals P N 9000 0427 L8 INFORMATION Intelligent Loop Interface Main Board Intelligent Loop Interface Main Board Intelligent Loop Interface Expansion Board Intelligent Loop Interface Expansion Board Addressable Node Expander Single Ring Addressable Node Expander Multi Ring Fiber Optic Addressable Node Expander Multi Ring Twisted pair LCD E3 LCD Keypad Display LCD Color Touchscreen with five programmable switches Network Repeater unshielded twisted pair Multi Mode Fiber Optic Module Single Mode Fiber Optic Module Digital Alarm Communicator Transmitter ANU 48 LED Driver Module Addressable Switch Module LCD Network Graphic Annunciator Power Supply Module 120 VAC Power Supply Module 220 240 VAC Remote LCD Display Remote LCD Display For additional information on the cabinets refer to the E3 Series Cabinets data sheet Part 9020 0649 Battery Bracket Kits information on the types of Seismic Battery Bracket Kits that are the Seismic Battery Bracket Kit Part Numbers and the Instructions refer to the following documents Seismic Battery Bracket Installation Guide P N 53839 E3 Series Cabinets Data Sheet P N 9020 0649 high speed 32 bit processor can easily implement a wide array of used in small office buildings or used in multi complex installations The 64 node networking is made possible by bits per second ARCNET communications using twisted pair cable fiber optic cable or a combination of both In addition Addressable Node Expander ANX board expands the network to nodes The basic E3 Series is equipped with the following modules PM 9 Power Supply ASM 16 Addressable Switch Module ILI MB E3 ILI95 MB E3 Intelligent Loop Interface Main Board ILI S E3 ILI95 S E3 Intelligent Loop Interface Expansion Board LCD E3 LCD Keypad Display ASM 16 features 16 software programmable switches each by red green and yellow LEDs that can be programmed indicate the operation of the switches Additional ASM 16 modules be added to expand the operation to a plateau previously Intelligent Loop Interface Expansion Board ILI S E3 ILI95 S E3 the E3 Series control panel with two additional electrically signaling line circuits The layout is similar to the ILI MB E3 with the exception that a number of components are It occupies one node on the Broadband network ILI MB E3 ILI95 MB E3 can support as many as sixteen ANU 48 Driver modules supporting hundreds of LEDs on a third party annunciator to use for remote annunciation The ANU 48 may be installed in any Listed remote annunciator It can be located via an RS 485 serial interface An array of cabinets for neat compact attractive installations E3 Series Expandable Emergency Evacuation System offers four size options A typical cabinet includes a backbox an inner door an outer door The E3 Series cabinet assembly is a compact 19 3 8 cm wide wall mounted enclosure Cabinet A includes the following four options Cabinet A1 inner door mounted to the backbox backbox houses one NGA module Cabinet A2 inner door mounted to the backbox The backbox houses one LCD E3 module Two or three bay inner door mounted to the backbox The backbox typically houses one LCD E3 or one NGA and one or two ASM 16 modules Cabinet B contains a space for the following modules installed inside backbox ILI MB E3 ILI95 MB E3 ANX ILI S E3 RPT E3 UTP PM 9 PM 9G DACT E3 ILI95 S E3 module options mounted on the backbox include the 2 bay inner door houses one LCD E3 module and one ASM 16 Both Cabinets C and D include the following Pre assembled outer door that provides visibility to the fire fighter phone handset and a microphone voice messaging system Two inner door panel selections that may contain optional modules to meet the facility operation requirements 2 of 3 9020 0637 T SERIES FIRE ALARM CONTROL PANEL TECHNICAL SPECIFICATIONS Series Velociti Series and are registered of Honeywell Inc is a registered trademark of Laboratories Inc document