AAD 8100 FAAST Fire Alarm Sensing Technology Provides the SLC connectivity via the Velociti Protocol Supports up to 159 FAAST devices per loop Detection as precise as 0.00046 ft obscuration five 5 alarm levels and two sensitivity modes application flexibility Offers dual flow detection including both ultrasonic and sensing for pipe and chamber air flow mea A single device protects up to 8,000 square feet Applies advanced detection algorithms to reject com nuisance conditions Uses a Patented particle separator and a field replace filter to remove contaminants from the system Employs PipeIQ software that provides an intuitive layout configuration and monitoring all in one Has an on board Ethernet interface that enables monitoring and e mail status updates Fault indicators exhibit a broad spectrum of events Unique air flow pendulum graph verifies pipe network Particulate graph displays subtle environmental for early problem indications 7259 1703 0177 Gamewell FCI Intelligent FAAST AAD 8100 Aspi Smoke Detector combines dual source blue LED infrared laser optical smoke detection with the fire control panel connectivity via the Velociti mode to high sensitivity to fire with intelligent reporting In addition the FAAST can provide enhanced to a nuisance particulate As a result FAAST can highly accurate Very Early Warning Fire Detection over the Signaling Line Circuit SLC to a fire alarm panel via the Velociti protocol This process maximum control over mission critical and chal environments Moreover the FAAST can seam integrate with an existing fire signaling circuit Intelligent FAAST Detector can be wired to a new or SLC that is used for transmitting communica directly to a fire alarm control panel via the Velociti without using extra hardware In the Velociti mode AAD 8100 FAAST will report back to the fire alarm panel as an Aspirating detector By setting the sen levels in PipeIQ the fire alarm control panel will pre alarm and alarm conditions based on the feed sent from the FAAST unit Using the Velociti mode to 159 units can populate one SLC the initial system creation FAAST design configura and monitoring software PipeIQ guide users through layout An installed device can be monitored through integral display by any of the following ways FAAST is connected to the Internet it can also e status updates to the appropriate personnel a computer connected to the device through a web browser complimentary download of the PipeIQ software pro is available at systemsensor com faast and Acclimate are registered trademarks of Honeywell International Inc is a registered trademark of System Sensor Inc is a registered trademark of Underwriter Laboratories Inc GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved Rev B page 1 of 2 FAAST Specifications Specifications Supply Voltage 18 30 VDC Reset Time Reset Operating Current 500 mA 24 VDC monitor must be pulled for a minimum of 100 ms sec mA All relays active all levels displayed 24 VDC to 32 VDC SLC Current Voltage Range Contact Ratings 3.0 A 30 VDC A 125 VAC Ratings Temperature 32 0 to 100 38 Air Range Rating Area Movement Specifications Access 20 to 140 60 to 95 non condensing sq ft 800 sq m ft min 0 1,219 m min inches 33.7 cm inches 33 cm inches 12.7 cm 1 inch 2.54 cm cable entry on top and bottom of unit AWG 2.05 mm max to AWG 0.5 mm min Gauge ft 80 m Single Pipe Branched 2 Length Air Inlet Outside Pipe Pipe Diameter 0.591 to 0.827 inches holes ft 50 m each branch inches IPS 25 mm Range Log Weight mm to 6.25 Obs ft to 20.5 Obs m form C 3 AMP programmable or non latching events stored monitoring E mail address alerts lbs 5.3 kg packing material 1 Intelligent FAAST User Interface Display User Interface consists of 5 Alarm levels Alert Fire 1 10 Particulate levels Action 1 Fire 2 10 Bi color Flow and Fault graph Action 2 Information Number Description Sensor Intelligent FAAST Fire Aspiration Sensing Technology Information Kit a Instruction Manual Replacement Air Filter Assembly Additional accessory information including part num can be accessed at systemsensor com faast Card Pipe and Fittings Rev B page 2 of 2 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118

Related Files